Ferromagnetic resonance detection for magnetic microbead sensors

被引:6
|
作者
Ghionea, Simon [1 ]
Dhagat, Pallavi [1 ]
Jander, Albrecht [1 ]
机构
[1] Oregon State Univ, Corvallis, OR 97330 USA
基金
美国国家科学基金会;
关键词
biomedical transducers; ferroresonance; magnetic; resonance; microsensors;
D O I
10.1109/JSEN.2008.923904
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel detection scheme for magnetic beads used to label target molecules in immunoassay based sensors. The beads are detected inductively using a microwave circuit consisting of a slotline and coplanar waveguide (CPW) fabricated in a single metal layer. The waveguides are terminated at a short-circuited junction that serves as the active sensor area. When the slotline is excited by an input radio frequency (RF) signal, ac magnetic fields are generated at the junction. These fields are orthogonal to the propagation mode allowed in CPWs. As a result, the signal from the slotline does not nominally couple into the CPW. In the presence of a bead immobilized at the junction, fields from the slotline are distorted and the signal is coupled to the output at the CPW. The output signal is further enhanced by exciting ferromagnetic resonance in the bead. Simulation results indicate a single bead to be detectable with a sensitivity of 1-10 mu V/V depending on its location in the active sensor area and the waveguide geometry. The distinctive advantages of this detection technique are ease of implementation, requiring simple and inexpensive fabrication processes; and suitability for integration in lab-on-a-chip systems.
引用
收藏
页码:896 / 902
页数:7
相关论文
共 50 条
  • [31] NUCLEAR MAGNETIC RESONANCE IN FERROMAGNETIC MNB
    HIHARA, T
    HIRAHARA, E
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1965, 20 (05) : 873 - &
  • [32] Sensitive detection of cardiac biomarkers using a magnetic microbead immunoassay
    Woolley, Christine F.
    Hayes, Mark A.
    ANALYTICAL METHODS, 2015, 7 (20) : 8632 - 8639
  • [33] MAGNETIC STRUCTURE OF THIN MAGNETIC FILMS AND FERROMAGNETIC RESONANCE
    IGNATCHENKO, VA
    SOVIET PHYSICS JETP-USSR, 1968, 27 (01): : 162 - +
  • [34] Detection of ferromagnetic nanowires using GMR sensors
    Anguelouch, A
    Reich, DH
    Chien, CL
    Tondra, M
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) : 2997 - 2999
  • [35] FERROMAGNETIC-RESONANCE FLAW DETECTION
    AULD, BA
    PHYSICS IN TECHNOLOGY, 1981, 12 (04): : 149 - 154
  • [36] Detection of ferromagnetic resonance for distribution system
    Yang, Rui
    Zeng, Xiangjun
    Yang, Xiangui
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 922 - 926
  • [37] Novel Detection Schemes of Nuclear Magnetic Resonance and Magnetic Resonance Imaging: Applications from Analytical Chemistry to Molecular Sensors
    Harel, Elad
    Schroeder, Leif
    Xu, Shoujun
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 (01) : 133 - 163
  • [38] Detection of dc voltages generated in multilayered magnetic thin films undergoing ferromagnetic resonance
    Park, ER
    Oh, DK
    Lee, CE
    Kim, SH
    Lee, SR
    Kim, YK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2002, 41 (01) : L1 - L3
  • [39] Enhanced Detection of Magnetic Nanoparticles Using a Novel Microwave Ferromagnetic Resonance Imaging System
    Kaye, Cameron
    Gilmore, Colin
    LoVetri, Joe
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (03) : 936 - 947
  • [40] Local ferromagnetic resonance imaging with magnetic resonance force microscopy
    Obukhov, Yu.
    Pelekhov, D. V.
    Kim, J.
    Banerjee, P.
    Martin, I.
    Nazaretski, E.
    Movshovich, R.
    An, S.
    Gramila, T. J.
    Batra, S.
    Hammel, P. C.
    PHYSICAL REVIEW LETTERS, 2008, 100 (19)