Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: A numerical sensitivity study

被引:35
|
作者
Pianigiani, Silvia [1 ]
Chevalier, Yan [2 ]
Labey, Luc [2 ]
Pascale, Valerio [1 ,3 ]
Innocenti, Bernardo [2 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
[2] Smith & Nephew, European Ctr Knee Res, Louvain, Belgium
[3] Univ Milan, Dipartimento Tecnol Salute, Milan, Italy
关键词
TKA; Kinematics; Malalignment; Ligament position; Numerical simulation; Sensitivity analysis; FORCES; MODEL;
D O I
10.1016/j.jbiomech.2012.06.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Total Knee Arthroplasty (TKA) is a very successful surgical procedure but clinical outcomes were reported to be affected by implant design, ligament balancing, alignment or patient-related anatomical factors. It was recently demonstrated that malpositioning of the TKA components and patient related anatomical factors can considerably alter tibio-femoral (IF) and patellofemoral maximum contact forces. However, up to now, how a component malpositioning and different soft-tissue anatomy changes IF knee kinematics was not yet fully investigated. The goal of this study was to evaluate how sensitive IF kinematics are to these factors during a simulated loaded squat for different TKA designs. Four TKA types (a fixed bearing, posterior stabilized prosthesis; a high flexion fixed bearing guided motion prosthesis; a mobile bearing prosthesis and a hinge prosthesis) were virtually implanted on the same virtual cadaver leg model which underwent a loaded squat between 0 degrees and 120 degrees. The reference models were then modified to simulate either component malpositioning in several directions or changes in ligaments geometry by change in the collateral ligament insertions. The results showed that, for all implant designs, IF kinematics were affected by changes in implant positioning and anatomical factors. While the ranges of motion predicted for all tested configurations were generally similar to the reference configuration for each type of TKA, the modifications resulted in shifts in the maximum and minimum values for the IF rotations and translations. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2315 / 2323
页数:9
相关论文
共 50 条
  • [31] Alterations of kinematics in knees after single versus multiple radius femoral prostheses total knee arthroplasty: a retrospective study
    Li, Mengyuan
    Fu, Guangtao
    Huang, Wenhan
    Lin, Bofu
    Zhang, Ruiying
    Zhang, Yu
    Ma, Yuanchen
    Zheng, Qiujian
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [32] Alterations of kinematics in knees after single versus multiple radius femoral prostheses total knee arthroplasty: a retrospective study
    Mengyuan Li
    Guangtao Fu
    Wenhan Huang
    Bofu Lin
    Ruiying Zhang
    Yu Zhang
    Yuanchen Ma
    Qiujian Zheng
    BMC Musculoskeletal Disorders, 21
  • [33] Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study
    Saiki, Yoshitomo
    Ojima, Tomohiro
    Kabata, Tamon
    Hayashi, Seigaku
    Tsuchiya, Hiroyuki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2267 - 2276
  • [34] Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study
    Yoshitomo Saiki
    Tomohiro Ojima
    Tamon Kabata
    Seigaku Hayashi
    Hiroyuki Tsuchiya
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 2267 - 2276
  • [35] Comparative Study of Kinematics and Kinetics of Knee Joint between Normal Knee and Undergone Total Knee Arthroplasty during Sit-to-Stand
    Phombut, Chotchuang
    Rooppakhun, Supakit
    Chaiyasit, Kasiwat
    Bhakdisongkhram, Gun
    2024 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND APPLICATIONS, ICBEA 2024, 2024, : 93 - 98
  • [36] Effect on patellar kinematics of the different patellar component designs in total knee arthroplasty: intraoperative measurement of dome type versus anatomic type
    Mochizuki, Takeshi
    Yano, Koichiro
    Ikari, Katsunori
    Hiroshima, Ryo
    Okazaki, Ken
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (03): : 419 - 424
  • [37] Effect on patellar kinematics of the different patellar component designs in total knee arthroplasty: intraoperative measurement of dome type versus anatomic type
    Takeshi Mochizuki
    Koichiro Yano
    Katsunori Ikari
    Ryo Hiroshima
    Ken Okazaki
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 419 - 424
  • [38] Does Femoral Notching During Total Knee Arthroplasty Influence Periprosthetic Fracture. A Prospective Study
    Puranik, Harish G.
    Mukartihal, Ravikumar
    Patil, Sharan S.
    Dhanasekaran, Soundar Rajan
    Menon, Venugopal K.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (06): : 1244 - 1249
  • [39] BIOMECHANICAL ANALYSIS OF DIFFERENT PRODISC-C ARTHROPLASTY DESIGNS AFTER IMPLANTATION: A NUMERICAL SENSITIVITY STUDY
    Tang, Qiaohong
    Wang, Lizhen
    Mo, Zhongjun
    Li, Qi
    Yao, Jie
    Du, Chengfei
    Fan, Yubo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (01)
  • [40] Potential risk of excising the femoral insertion of the popliteus tendon during primary total knee arthroplasty: a biometric study
    Takahashi, Atsushi
    Sugita, Takehiko
    Aizawa, Toshimi
    Chiba, Daisuke
    Kamimura, Masayuki
    Aki, Takashi
    Itoi, Eiji
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (06) : 1030 - 1035