Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: A numerical sensitivity study

被引:35
|
作者
Pianigiani, Silvia [1 ]
Chevalier, Yan [2 ]
Labey, Luc [2 ]
Pascale, Valerio [1 ,3 ]
Innocenti, Bernardo [2 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
[2] Smith & Nephew, European Ctr Knee Res, Louvain, Belgium
[3] Univ Milan, Dipartimento Tecnol Salute, Milan, Italy
关键词
TKA; Kinematics; Malalignment; Ligament position; Numerical simulation; Sensitivity analysis; FORCES; MODEL;
D O I
10.1016/j.jbiomech.2012.06.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Total Knee Arthroplasty (TKA) is a very successful surgical procedure but clinical outcomes were reported to be affected by implant design, ligament balancing, alignment or patient-related anatomical factors. It was recently demonstrated that malpositioning of the TKA components and patient related anatomical factors can considerably alter tibio-femoral (IF) and patellofemoral maximum contact forces. However, up to now, how a component malpositioning and different soft-tissue anatomy changes IF knee kinematics was not yet fully investigated. The goal of this study was to evaluate how sensitive IF kinematics are to these factors during a simulated loaded squat for different TKA designs. Four TKA types (a fixed bearing, posterior stabilized prosthesis; a high flexion fixed bearing guided motion prosthesis; a mobile bearing prosthesis and a hinge prosthesis) were virtually implanted on the same virtual cadaver leg model which underwent a loaded squat between 0 degrees and 120 degrees. The reference models were then modified to simulate either component malpositioning in several directions or changes in ligaments geometry by change in the collateral ligament insertions. The results showed that, for all implant designs, IF kinematics were affected by changes in implant positioning and anatomical factors. While the ranges of motion predicted for all tested configurations were generally similar to the reference configuration for each type of TKA, the modifications resulted in shifts in the maximum and minimum values for the IF rotations and translations. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2315 / 2323
页数:9
相关论文
共 50 条
  • [21] Varus femoral and tibial coronal alignments result in different kinematics and kinetics after total knee arthroplasty
    Mutsumi Watanabe
    Shinichi Kuriyama
    Shinichiro Nakamura
    Yoshihisa Tanaka
    Kohei Nishitani
    Moritoshi Furu
    Hiromu Ito
    Shuichi Matsuda
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 3459 - 3466
  • [22] Are Western Knee Designs Dimensionally Correct for Korean Women? A Morphometric Study of Resected Femoral Surfaces during Primary Total Knee Arthroplasty
    Kim, Jun-Bae
    Lyu, Suk-Joo
    Kang, Hyung Wook
    CLINICS IN ORTHOPEDIC SURGERY, 2016, 8 (03) : 254 - 261
  • [23] A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait
    de Ruiter L.
    Janssen D.
    Briscoe A.
    Verdonschot N.
    Journal of Experimental Orthopaedics, 4 (1)
  • [24] Comparative Study on Three Different Designs of Locking Mechanisms in Total Knee Arthroplasty
    Cho, Byung Woo
    Hong, Hyoung-Taek
    Koh, Yong-Gon
    Park, Kwan Kyu
    Kang, Kyoung-Tak
    BIOENGINEERING-BASEL, 2025, 12 (02):
  • [25] Rate of complications and short-term Functional Results of Revision Total Knee Arthroplasty for Tibio-femoral Instability: do stability and range of motion are restored in 62 revisions
    Labouyrie, Antoine
    Artus, Julien
    Putman, Sophie
    Trouillez, Teddy
    Migaud, Henri
    Asquier, Gilles P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2025, 111 (01)
  • [26] Computer-based analysis of different component positions and insert thicknesses on tibio-femoral and patello-femoral joint dynamics after cruciate-retaining total knee replacement
    Kebbach, Maeruan
    Geier, Andreas
    Darowski, Martin
    Krueger, Sven
    Schilling, Christoph
    Grupp, Thomas M.
    Bader, Rainer
    KNEE, 2023, 40 : 152 - 165
  • [27] Intraoperative femoral rotational kinematics are similar in varus and valgus knees during medial pivot total knee arthroplasty
    Yamagami, Ryota
    Inui, Hiroshi
    Taketomi, Shuji
    Kono, Kenichi
    Kawaguchi, Kohei
    Sameshima, Shin
    Kage, Tomofumi
    Arakawa, Takahiro
    Tanaka, Sakae
    CLINICAL BIOMECHANICS, 2023, 101
  • [28] Videofluoroscopic Evaluation of the Influence of a Gradually Reducing Femoral Radius on Joint Kinematics During Daily Activities in Total Knee Arthroplasty
    List, Renate
    Schutz, Pascal
    Angst, Michi
    Ellenberger, Lynn
    Datwyler, Katrin
    Ferguson, Stephen J.
    Von Eisenhart-Rothe, Ruediger
    Schwaller, Christoph
    JOURNAL OF ARTHROPLASTY, 2020, 35 (10): : 3010 - 3030
  • [29] A lateral retinacular release during total knee arthroplasty changes femorotibial kinematics: an in vitro study
    Steinbrueck, Arnd
    Schroeder, Christian
    Woiczinski, Matthias
    Glogaza, Alexander
    Mueller, Peter E.
    Jansson, Volkmar
    Fottner, Andreas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (03) : 401 - 407
  • [30] A lateral retinacular release during total knee arthroplasty changes femorotibial kinematics: an in vitro study
    Arnd Steinbrück
    Christian Schröder
    Matthias Woiczinski
    Alexander Glogaza
    Peter E. Müller
    Volkmar Jansson
    Andreas Fottner
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 401 - 407