Liquid chromatography-tandem mass spectrometric assay for sorafenib and sorafenib-glucuronide in mouse plasma and liver homogenate and identification of the glucuronide metabolite

被引:34
|
作者
Sparidans, Rolf W. [1 ]
Vlaming, Maria L. H. [2 ]
Lagas, Jurjen S. [2 ]
Schinkel, Afred H. [2 ]
Schellens, Jan H. M. [1 ,2 ]
Beijnen, Jos H. [1 ,2 ,3 ]
机构
[1] Univ Utrecht, Fac Sci, Dept Pharmaceut Sci, Sect Biomed Anal,Div Drug Toxicol, NL-3584 CA Utrecht, Netherlands
[2] Netherlands Canc Inst, Dept Med Oncol & Expt Therapy, NL-1066 CX Amsterdam, Netherlands
[3] Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1066 EC Amsterdam, Netherlands
关键词
Sorafenib; Sorafenib-glucuronide; LC/MS/MS; Mouse plasma; Mouse liver homogenate; RAF KINASE INHIBITOR; CARCINOMA; VALIDATION; DRUG;
D O I
10.1016/j.jchromb.2008.12.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The first bioanalytical assay for the simultaneous determination of sorafenib and sorafenib-glucuronide in mouse plasma and liver homogenate was developed and validated. In addition, the structure of the glucuronide metabolite was elucidated. The quantitative assay started with addition of isotopically labeled internal standards to a 20 mu l sample volume and protein precipitation with acetonitrile, the supernatant was diluted with water and injected into the chromatographic system. A polar embed-ded reversed-phase column with gradient elution using formic acid in water-acetonitrile was used. The eluate was transferred into an electrospray interface with positive ionization and the analytes were detected and quantified using triple quadrupole mass spectrometry. The assay was validated in the ranges 10-5000 ng/ml for sorafenib and 1-500 ng/ml for sorafenib-glucuronide, the lowest levels of these ranges (10 and 1 ng/ml) being the lower limits of quantification (LLQ). Within day precisions were 2-8%, between day precisions 2-10% (both excluded the LLQ level of the glucuronide) and accuracies were between 89% and 106%. Both analytes were chemically stable under all relevant conditions. The assay was successfully applied in pilot in vivo pharmacokinetic studies with sorafenib in mice. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass spectrometric assay with a novel method of quantitation for the simultaneous determination of bulaquine and its metabolite, primaquine, in monkey plasma
    Nitin, M
    Rajanikanth, M
    Lal, J
    Madhusudanan, KP
    Gupta, RC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (02): : 253 - 263
  • [42] Validation of a sequential extraction and liquid chromatography-tandem mass spectrometric method for determination of dihydrotestosterone, androstanediol and androstanediol-glucuronide in prostate tissues
    Adomat, Hans H.
    Bains, Onkar S.
    Lubieniecka, Joanna M.
    Gleave, Martin E.
    Guns, Emma S.
    Grigliatti, Thomas A.
    Reid, Ronald E.
    Riggs, K. Wayne
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 84 - 95
  • [43] Simultaneous determination of thienorphine and its active metabolite thienorphine-glucuronide in rat plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic studies
    Kong, Qi
    Qiao, Jianzhong
    Wang, Xiaoying
    Yuan, Shulan
    Zhang, Zhenqing
    Gong, Zehui
    Ruan, Jinxiu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (01): : 52 - 61
  • [44] A flexible and high throughput liquid chromatography-tandem mass spectrometric assay for the quantitation of telcagepant in human plasma
    Du, Lihong
    Miller-Stein, Cynthia M.
    Valesky, Robert J.
    Martucci, Ashley N.
    Woolf, Eric J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15): : 1465 - 1471
  • [45] Liquid chromatography-tandem mass spectrometric assay for determination of unstable arecoline in rat plasma and its application
    Pan, Hong
    Huang, Linyan
    Li, Yi
    Zhou, Xumei
    Lu, Yuanfu
    Shi, Fuguo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1070 : 112 - 116
  • [46] Liquid chromatography-tandem mass spectrometric assay for eltrombopag in 50 μL of human plasma: A pharmacokinetic study
    Maddela, Rambabu
    Gajula, Ramakrishna
    Pilli, Nageswara Rao
    Siddiraju, Sridhar
    Maddela, Srinubabu
    Makula, Ajitha
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 68 - 73
  • [47] Liquid chromatography-tandem mass spectrometric assay for the nucleoside reverse transcriptase inhibitor emtricitabine in human plasma
    Sparidans, Rolf W.
    Prins, Jan M.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 621 - 627
  • [48] Liquid chromatography-tandem mass spectrometric assay for the determination of vaccarin in rat plasma: application to a pharmacokinetic study
    Yang, Guilin
    Zhang, Nan
    Wang, Tiance
    Zhang, Shudong
    Xu, Rihao
    Zhu, Zhicheng
    Liu, Kexiang
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (12) : 1789 - 1794
  • [49] Development of a method to measure plasma sorafenib concentration by liquid chromatography tandem mass spectrometry
    Vidali, M.
    Bagnati, M.
    Albertario, M.
    Atzeni, N.
    Scarano, D.
    Castellina, V
    Viano, I
    Colangelo, D.
    Bellomo, G.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 553 - 553
  • [50] DEVELOPMENT OF A METHOD TO MEASURE PLASMA SORAFENIB CONCENTRATION BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY
    Vidali, M.
    Bagnati, M.
    Albertario, M.
    Atzeni, N.
    Scarano, D.
    Castellina, V.
    Viano, I.
    Colangelo, D.
    Bellomo, G.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S802 - S802