Liquid chromatography-tandem mass spectrometric assay for sorafenib and sorafenib-glucuronide in mouse plasma and liver homogenate and identification of the glucuronide metabolite

被引:34
|
作者
Sparidans, Rolf W. [1 ]
Vlaming, Maria L. H. [2 ]
Lagas, Jurjen S. [2 ]
Schinkel, Afred H. [2 ]
Schellens, Jan H. M. [1 ,2 ]
Beijnen, Jos H. [1 ,2 ,3 ]
机构
[1] Univ Utrecht, Fac Sci, Dept Pharmaceut Sci, Sect Biomed Anal,Div Drug Toxicol, NL-3584 CA Utrecht, Netherlands
[2] Netherlands Canc Inst, Dept Med Oncol & Expt Therapy, NL-1066 CX Amsterdam, Netherlands
[3] Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1066 EC Amsterdam, Netherlands
关键词
Sorafenib; Sorafenib-glucuronide; LC/MS/MS; Mouse plasma; Mouse liver homogenate; RAF KINASE INHIBITOR; CARCINOMA; VALIDATION; DRUG;
D O I
10.1016/j.jchromb.2008.12.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The first bioanalytical assay for the simultaneous determination of sorafenib and sorafenib-glucuronide in mouse plasma and liver homogenate was developed and validated. In addition, the structure of the glucuronide metabolite was elucidated. The quantitative assay started with addition of isotopically labeled internal standards to a 20 mu l sample volume and protein precipitation with acetonitrile, the supernatant was diluted with water and injected into the chromatographic system. A polar embed-ded reversed-phase column with gradient elution using formic acid in water-acetonitrile was used. The eluate was transferred into an electrospray interface with positive ionization and the analytes were detected and quantified using triple quadrupole mass spectrometry. The assay was validated in the ranges 10-5000 ng/ml for sorafenib and 1-500 ng/ml for sorafenib-glucuronide, the lowest levels of these ranges (10 and 1 ng/ml) being the lower limits of quantification (LLQ). Within day precisions were 2-8%, between day precisions 2-10% (both excluded the LLQ level of the glucuronide) and accuracies were between 89% and 106%. Both analytes were chemically stable under all relevant conditions. The assay was successfully applied in pilot in vivo pharmacokinetic studies with sorafenib in mice. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [31] Validation of a Liquid Chromatography-Tandem Mass Spectrometric Assay for Quantitative Analysis of Lenvatinib in Human Plasma
    Ogawa-Morita, Tomoko
    Sano, Yoshiyuki
    Okano, Tomoka
    Fujii, Hirofumi
    Tahara, Makoto
    Yamaguchi, Masakazu
    Minami, Hironobu
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 2017
  • [32] Validation of a rapid liquid chromatography-tandem mass spectrometric assay for the determination of octreotide plasma concentrations
    Capron, Arnaud
    Destree, Jennifer
    Maiter, Dominique
    Wallemacq, Pierre
    CLINICAL BIOCHEMISTRY, 2014, 47 (1-2) : 139 - 141
  • [33] Elimination of matrix effects in urine for determination of ethyl glucuronide by liquid chromatography-tandem mass spectrometry
    Kul, Aykut
    Sagirli, Olcay
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (23)
  • [34] Ethyl glucuronide determination in meconium and hair by hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Tarcomnicu, Isabela
    van Nuijs, Alexander L. N.
    Aerts, Katrien
    De Doncker, Mireille
    Covaci, Adrian
    Neels, Hugo
    FORENSIC SCIENCE INTERNATIONAL, 2010, 196 (1-3) : 121 - 127
  • [35] Sensitive detection of 3′-hydroxy-stanozolol glucuronide by liquid chromatography-tandem mass spectrometry
    Tudela, E.
    Deventer, K.
    Van Eenoo, P.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1292 : 195 - 200
  • [36] Determination of salbutamol and salbutamol glucuronide in human urine by means of liquid chromatography-tandem mass spectrometry
    Mareck, Ute
    Guddat, Sven
    Schwenke, Anne
    Beuck, Simon
    Geyer, Hans
    Flenker, Ulrich
    Elers, Jimmi
    Backer, Vibeke
    Thevis, Mario
    Schaenzer, Wilhelm
    DRUG TESTING AND ANALYSIS, 2011, 3 (11-12) : 820 - 827
  • [37] Determination of ethyl glucuronide in human hair by hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Yaldiz, Fadile
    Daglioglu, Nebile
    Hilal, Ahmet
    Keten, Alper
    Gulmen, Mete Korkut
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2013, 20 (07) : 799 - 802
  • [38] A liquid chromatography-tandem mass spectrometric method for quantification of curcuminoids in cell medium and mouse plasma
    Saradhi, U. V. R. Vijaya
    Ling, Yonghua
    Wang, Jiang
    Chiu, Ming
    Schwartz, Eric B.
    Fuchs, James R.
    Chan, Kenneth K.
    Liu, Zhongfa
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (30): : 3045 - 3051
  • [39] Liquid chromatography-tandem mass spectrometric analysis of stobadine in human plasma
    Abdel-Hamid, ME
    Novotny, L
    Stankovicova, M
    Benes, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 383 - 393
  • [40] A rapid and sensitive method for determination of sorafenib in human plasma using a liquid chromatography/tandem mass spectrometry assay
    Zhao, Ming
    Rudek, Michelle A.
    He, Ping
    Hafner, Frank-Thorsten
    Radtke, Martin
    Wright, John J.
    Smith, B. Douglas
    Messersmith, Wells A.
    Hidalgo, Manuel
    Baker, Sharyn D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 1 - 7