Reference value of perimeter-derived diameter assessed by three-dimensional transesophageal echocardiography in left atrial appendage occluder size selection

被引:4
|
作者
Kong, Dehong [1 ,2 ,3 ]
Jiang, Yingying [1 ,2 ,3 ]
Zhang, Xiaochun [2 ]
Jin, Qinchun [2 ]
Dong, Lili [1 ,2 ,3 ]
Zhou, Daxin [2 ]
Shu, Xianhong [1 ,2 ,3 ]
Pan, Cuizhen [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Echocardiog, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Cardiovasc Dis, Shanghai, Peoples R China
[3] Shanghai Inst Med Imaging, Shanghai, Peoples R China
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2020年 / 37卷 / 11期
基金
中国国家自然科学基金;
关键词
left atrial appendage closure; three-dimensional transesophageal echocardiography; transcatheter device; COMPUTED-TOMOGRAPHY; CT ANGIOGRAPHY; CLOSURE; FIBRILLATION; STROKE; PREVENTION; WARFARIN; OUTCOMES; ANATOMY; IMPACT;
D O I
10.1111/echo.14705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of this study was to investigate the utility of perimeter-derived diameter (PDD) measured by three-dimensional (3D) transesophageal echocardiography (TEE) in predicting the size of left atrial appendage (LAA) occluder. Methods and results Left atrial appendage landing zone diameter (LZD) was measured by two-dimensional (2D) TEE, 3DTEE, and digital subtraction angiography (DSA) as LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD, LZD-DSAmax, respectively, before and during transcatheter LAA closure with Watchman devices in 100 patients. A difference of one or more device size intervals between the predicted size and the size actually implanted was defined as mismatching. Seventy-eight patients were followed up by TEE to obtain occluder compression ratio. The correlation between LZD and the final implanted occluder size was 0.559, 0.641, 0.754, 0.760, 0.782, and 0.848 for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively (P < .001). Matching ratio between the size predicted by retrospective measurements of LZD and the device size actually implanted was 65%, 57%, 66%, 63%, 70%, and 83% for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively. There was no significant difference in LZD value, matching ratio, and compression ratio between the patients with eccentric and noneccentric LAA landing zone (P > .05). Compression ratio of the mismatching subjects was higher than that in the matching subjects when evaluated by LZD-2Dmean, LZD-3Dmean, and LZD-PDD (P < .05). Conclusions Landing zone diameter derived from LAA perimeter measured by preprocedure 3DTEE showed reference value for LAA occluder size selection, providing superior correlation and matching ratio with the final implanted size and indicating the adjustment of oversizing.
引用
收藏
页码:1828 / 1837
页数:10
相关论文
共 50 条
  • [21] Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography
    Chen Ou-di
    Wu Wei-chun
    Jiang Yong
    Xiao Ming-hu
    Wang Hao
    CHINESE MEDICAL JOURNAL, 2012, 125 (19) : 3416 - 3420
  • [22] Real-Time Three-Dimensional Transesophageal Echocardiography of the Left Atrial Appendage: Initial Experience in the Clinical Setting
    Shah, Sanjiv J.
    Bardo, Dianna M. E.
    Sugeng, Lissa
    Weinert, Lynn
    Lodato, Joseph A.
    Knight, Bradley P.
    Lopez, John J.
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) : 1362 - 1368
  • [23] Role of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Percutaneous Epicardial Closure of the Left Atrial Appendage
    Joshi, Deepak
    Mazimba, Sula
    Kay, G. Neal
    Nanda, Navin C.
    Fan, Pohoey
    Schlotter, Florian
    Venkataraman, Rajesh
    Dumaswala, Bhavin
    Dumaswala, Komal
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (10): : 1256 - 1260
  • [24] Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography
    CHEN Ou-di
    WU Wei-chun
    JIANG Yong
    XIAO Ming-hu
    WANG Hao
    中华医学杂志(英文版), 2012, (19) : 3416 - 3420
  • [25] Real Time Three-Dimensional Transesophageal Echocardiography-Guided Placement of Left Atrial Appendage Occlusion Device
    Brinkman, Vincent
    Kalbfleisch, Steven
    Auseon, Alex
    Pu, Min
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (07): : 855 - 858
  • [26] Unknown Left Atrial Appendage Mass! Real-time Three-dimensional Transesophageal Echocardiography Helps in Identification
    Tewari, Prabhat
    Dixit, Aanchal
    Soori, Rashmi
    ANNALS OF CARDIAC ANAESTHESIA, 2018, 21 (01) : 97 - 98
  • [27] Left atrial appendage geometry and function using transesophageal three-dimensional echocardiography in atrial fibrillation: a new approach to characterize left atrial thrombogenic milieu
    Soulat-Dufour, L.
    Simon, T.
    Lang, S.
    Ederhy, S.
    Adavane-Scheuble, S.
    Chauvet-Droit, M.
    Capderou, E.
    Arnaud, C.
    Addetia, K.
    Lang, R.
    Scheuble, A.
    Hammoudi, N.
    Beraud, A.
    Boccara, F.
    Cohen, A.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [28] CHANGES OF LEFT ATRIAL APPENDAGE ORIFICE FOLLOWING PERCUTANEOUS LEFT ATRIAL APPENDAGE CLOSURE USING THREE-DIMENSIONAL ECHOCARDIOGRAPHY
    Ortiz-Leon, Xochitl
    Posada, Edith
    Chen, Wanwen
    Bregasi, Alda
    Crandall, Ian
    Pereira, Jason
    Miranda, Juan Betuel Ivey
    Akar, Joseph
    Lin, Ben A.
    McNamara, Robert
    Freeman, James
    Curtis, Jeptha P.
    Arias-Godinez, Jose Antonio
    Sugeng, Lissa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1708 - 1708
  • [29] Validation study of new left atrial appendage closure device measurement by two-dimensional and three-dimensional transesophageal echocardiography
    Ono, Sachiyo
    Maruo, Takeshi
    Kubo, Shunsuke
    Kadota, Kazushige
    JOURNAL OF ECHOCARDIOGRAPHY, 2024, 22 (01) : 16 - 24
  • [30] Validation study of new left atrial appendage closure device measurement by two-dimensional and three-dimensional transesophageal echocardiography
    Sachiyo Ono
    Takeshi Maruo
    Shunsuke Kubo
    Kazushige Kadota
    Journal of Echocardiography, 2024, 22 : 16 - 24