Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

被引:39
|
作者
Fuchs, Andreas [1 ]
Kuhl, J. Tobias [1 ]
Chen, Marcus Y. [2 ]
Helquist, Steffen [1 ]
Razeto, Marco [3 ]
Arakita, Kazumasa [4 ]
Steveson, Chloe [4 ]
Arai, Andrew E. [2 ]
Kofoed, Klaus F. [1 ,5 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Cardiol, DK-2100 Copenhagen, Denmark
[2] NHLBI, NIH, Bethesda, MD 20892 USA
[3] Toshiba Med Visualizat Syst Europe, Edinburgh, Midlothian, Scotland
[4] Toshiba Med Syst Corp, Otawara, Japan
[5] Univ Copenhagen, Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
关键词
Coronary; Subtraction; CT; CCTA; Angiography; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.jcct.2015.03.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis severity leading to false-positive results. In a pilot study, we tested the feasibility of a new coronary calcium image subtraction algorithm in relation to reader confidence and diagnostic accuracy. Methods: Forty-three patients underwent clinically indicated ICA and CCTA using a 320-detector row CT. Median Agatston score was 510. Two data sets were reconstructed: a conventional CCTA (CCTA(conv)) and a subtracted CCTA (CCTA(sub)), where calcifications detected on noncontrast images were subtracted from the CCTA. Reader confidence and concordance with ICA for identification of >50% stenosis were recorded. We defined target segments on CCTA(conv), as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTA(sub) was assessed. No approval from the ethics committee was required according to Danish law. Results: A total of 76 target segments were identified. The use of coronary calcium image subtraction improved the reader confidence in 66% of these segments. In target segments, specificity (86% vs 65%; P < .01) and positive predictive value (71% vs 51%, P = .03) were improved using CCTA(sub) compared to CCTA(conv), without loss in negative predictive value. Conclusions: Our initial experience with coronary calcium image subtraction suggests that it is feasible and could lead to an improvement in reader confidence and diagnostic accuracy for identification of significant coronary artery disease. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:393 / 398
页数:6
相关论文
共 50 条
  • [41] Transluminal attenuation gradient on 320-detector row CT (TAG320) adds incremental value to coronary angiography for detection of functionally significant stenosis
    Wong, D. T. L.
    Ko, B. S.
    Cameron, J. D.
    Nerlekar, N.
    Leung, M. C. H.
    Malaiapan, Y.
    Crossett, M.
    Leong, D. P.
    Meredith, I. T.
    Seneviratne, S. K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S2 - S2
  • [42] Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner
    Tomizawa, Nobuo
    Maeda, Eriko
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (07): : 1613 - 1618
  • [43] Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner
    Nobuo Tomizawa
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Shigeru Kiryu
    Kuni Ohtomo
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1613 - 1618
  • [44] Diagnostic value of four-dimensional CT angiography in arterial erectile dysfunction using 320-detector row dynamic volume CT
    Xu, Cheng-Cheng
    Ruan, Xin-Zhong
    Tang, Yi-Fan
    Pan, Jiao-Hai
    Wang, Guo-Yao
    Huang, Qiu-Li
    BIOSCIENCE REPORTS, 2017, 37
  • [45] Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
    Tomizawa, Nobuo
    Komatsu, Shuhei
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01): : 139 - 146
  • [46] Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
    Nobuo Tomizawa
    Shuhei Komatsu
    Masaaki Akahane
    Rumiko Torigoe
    Shigeru Kiryu
    Kuni Ohtomo
    The International Journal of Cardiovascular Imaging, 2012, 28 : 139 - 146
  • [47] Feasibility of Low-volume Injections of Contrast Material with a Body Weight-Adapted Iodine-Dose Protocol in 320-Detector Row Coronary CT Angiography
    Tatsugami, Fuminari
    Matsuki, Mitsuru
    Inada, Yuki
    Kanazawa, Shuji
    Nakai, Go
    Takeda, Yoshihiro
    Morita, Hideaki
    Takada, Haruhiko
    Ashida, Kenji
    Yoshikawa, Shushi
    Fukumura, Katsunori
    Narumi, Yoshifumi
    ACADEMIC RADIOLOGY, 2010, 17 (02) : 207 - 211
  • [48] Comparison of Standard- and Low-Tube Voltage 320-Detector Row Volume CT Angiography in Detection of Intracranial Aneurysms with Digital Subtraction Angiography as Gold Standard
    Sun, Gang
    Ding, Juan
    Lu, Yang
    Li, Min
    Li, Li
    Li, Guo-ying
    Zhang, Xu-ping
    ACADEMIC RADIOLOGY, 2012, 19 (03) : 281 - 288
  • [49] Clinical indications and utilization of 320-detector row CT in 2500 outpatients
    Tabibian, Benjamin
    Roach, Cayce J.
    Hanson, Eric H.
    Wynn, Brad L.
    Orrison, William W., Jr.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2011, 35 (04) : 266 - 274
  • [50] Radiation Dose of Second-Generation 320-Detector Row CT
    Qian, Xue-jiang
    RADIOLOGY, 2013, 268 (03) : 927 - 928