Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

被引:39
|
作者
Fuchs, Andreas [1 ]
Kuhl, J. Tobias [1 ]
Chen, Marcus Y. [2 ]
Helquist, Steffen [1 ]
Razeto, Marco [3 ]
Arakita, Kazumasa [4 ]
Steveson, Chloe [4 ]
Arai, Andrew E. [2 ]
Kofoed, Klaus F. [1 ,5 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Cardiol, DK-2100 Copenhagen, Denmark
[2] NHLBI, NIH, Bethesda, MD 20892 USA
[3] Toshiba Med Visualizat Syst Europe, Edinburgh, Midlothian, Scotland
[4] Toshiba Med Syst Corp, Otawara, Japan
[5] Univ Copenhagen, Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
关键词
Coronary; Subtraction; CT; CCTA; Angiography; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.jcct.2015.03.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis severity leading to false-positive results. In a pilot study, we tested the feasibility of a new coronary calcium image subtraction algorithm in relation to reader confidence and diagnostic accuracy. Methods: Forty-three patients underwent clinically indicated ICA and CCTA using a 320-detector row CT. Median Agatston score was 510. Two data sets were reconstructed: a conventional CCTA (CCTA(conv)) and a subtracted CCTA (CCTA(sub)), where calcifications detected on noncontrast images were subtracted from the CCTA. Reader confidence and concordance with ICA for identification of >50% stenosis were recorded. We defined target segments on CCTA(conv), as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTA(sub) was assessed. No approval from the ethics committee was required according to Danish law. Results: A total of 76 target segments were identified. The use of coronary calcium image subtraction improved the reader confidence in 66% of these segments. In target segments, specificity (86% vs 65%; P < .01) and positive predictive value (71% vs 51%, P = .03) were improved using CCTA(sub) compared to CCTA(conv), without loss in negative predictive value. Conclusions: Our initial experience with coronary calcium image subtraction suggests that it is feasible and could lead to an improvement in reader confidence and diagnostic accuracy for identification of significant coronary artery disease. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:393 / 398
页数:6
相关论文
共 50 条
  • [21] The evolution and investigation of native coronary arteries in patients after coronary stent implantation: a study by 320-detector CT angiography
    Yu-Hsiang Juan
    Yu-Chieh Huang
    Zhonghua Sun
    I-Chang Hsieh
    Wen-Hui Chan
    Chun-Chi Chen
    Kuo-Chun Hung
    Ming-Shien Wen
    Yung-Liang Wan
    The International Journal of Cardiovascular Imaging, 2014, 30 : 13 - 24
  • [22] Influence of hemodynamic parameters on coronary artery attenuation with 320-detector coronary CT angiography
    Tomizawa, Nobuo
    Komatsu, Shuhei
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : 230 - 233
  • [23] VALIDATION OF ISOTROPIC CORONARY ARTERY CALCIUM MEASUREMENTS USING 320-DETECTOR ROW CT AGAINST INTRAVASCULAR ULTRASOUND WITH RADIOFREQUENCY BACKSCATTER
    Dhungel, Abinashi
    Qian, Zhen
    Rinehart, Sarah
    Bhatt, Kunal
    Odeh, Wassim
    Figueroa, Jesus Gustavo Vazquez
    Weeks, Michael
    Voros, Szilard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E165 - E165
  • [24] 320-detector row CT coronary angiography: effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure
    Sun, G.
    Li, M.
    Jiang, X-S
    Li, L.
    Peng, Z-H
    Li, G-Y
    Xu, L.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : E388 - E394
  • [25] Noninvasive Evaluation of Cerebral Arteriovenous Malformations by 4D-CT Angiography using 320-detector row CT
    Tajiri, Hiroyuki
    Jin, Lee
    Tsukiyama, Toshitaka
    Suzuki, Yumiko
    STROKE, 2013, 44 (02)
  • [26] Noninvasive Evaluation of Cerebral Arteriovenous Malformations by 4D-CT Angiography using 320-detector Row CT
    Tajiri, H.
    Lee, J.
    Tsukiyama, T.
    Suzuki, Y.
    Sekine, S.
    Shimizu, T.
    Ohiwa, T.
    Kurata, T.
    Mitsuoka, K.
    Kinoshita, D.
    Uzuki, D.
    Yoshida, I.
    Tanabe, K.
    Koizumi, M.
    CEREBROVASCULAR DISEASES, 2013, 35 : 390 - 390
  • [27] Fully Automated 3D-Coronary Endothelial Shear Stress Based on 320-Detector Row CT Angiography
    Rybicki, F.
    Mitsouras, D.
    Nallamshetty, L.
    Coskun, A.
    Feldman, C.
    Stone, P.
    Steigner, M.
    Chatzizisis, Y.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [28] Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner
    Einstein, Andrew J.
    Elliston, Carl D.
    Arai, Andrew E.
    Chen, Marcus Y.
    Mather, Richard
    Pearson, Gregory D. N.
    DeLaPaz, Robert L.
    Nickoloff, Edward
    Dutta, Ajoy
    Brenner, David J.
    RADIOLOGY, 2010, 254 (03) : 698 - 706
  • [29] Body Size-Adapted Dose of Contrast Material and Scanning Protocol in 320-Detector Row CT Coronary Angiography
    Tatsugami, Fuminari
    Matsuki, Mitsuru
    Nakai, Go
    Inada, Yuki
    Kanazawa, Shuji
    Takeda, Yoshihiro
    Morita, Hideaki
    Takada, Haruhiko
    Yoshikawa, Shushi
    Fukumura, Katsunori
    Narumi, Yoshifumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) : 475 - 479
  • [30] Cerebral Aneurysms: Accuracy of 320-Detector Row Nonsubtracted and Subtracted Volumetric CT Angiography for Diagnosis
    Chen, Wenhua
    Xing, Wei
    Peng, Ya
    He, Zhongming
    Wang, Caoye
    Wang, Qi
    RADIOLOGY, 2013, 269 (03) : 841 - 849