Comparing the embolic potential of open and closed cell stents during carotid angioplasty and stenting

被引:20
|
作者
Tadros, Rami O. [1 ]
Spyris, Constantinos T. [1 ]
Vouyouka, Ageliki G. [1 ]
Chung, Christine [1 ]
Krishnan, Prakash [1 ]
Arnold, Margaret W. [1 ]
Marin, Michael L. [1 ]
Faries, Peter L. [1 ]
机构
[1] Mt Sinai Sch Med, Dept Vasc Surg, New York, NY 10029 USA
关键词
ENDARTERECTOMY; DESIGN; TRIAL; INTERVENTION; PREVENTION; IMPACT; RISK;
D O I
10.1016/j.jvs.2011.12.077
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: We sought to determine the effects of open (O) and closed (C) cell stents on the size and number of embolic particles generated during carotid artery stenting (CAS) and assess the impact on outcome. Methods: Embolic debris from carotid filters after CAS was analyzed using photomicroscopy and imaging software. Patient comorbidities, preoperative cerebrovascular symptoms, stent type, and outcomes (perioperative major adverse events) were examined. Results: Carotid filters from 173 consecutive CAS procedures (O, 125 and C, 48) were reviewed. The mean age was 70.9 +/- 9.2 years; 58% were men. Mean stenosis was 88.2% +/- 8.1%; 36.6% had neurological symptoms preprocedurally. There was no difference in preoperative symptoms between the two groups (O, 38.7% vs C, 31.3%; P = not significant [NS]). However, closed cell stent use was associated with higher degree of stenosis (O, 87.2% +/- 8.0% vs C, 90.6% +/- 7.8%; P = .01), an older age (O, 70.0 +/- 8.6 years vs C, 73.4 +/- 10.2 years; P = .03), and peripheral arterial disease (21.1% vs 43.5%; P = .01). A larger mean particle size was observed in patients treated with open cell stents compared to closed cell stents (O, 416.5 +/- 335.7 mu m vs C, 301.1 +/- 251.3 mu m; P = .03). There was no significant difference in the total number of particles (O, 13.8 +/- 21.5 vs C, 17.6 +/- 19.9; P = NS), periprocedural stroke (P = NS), and major adverse events between the two groups (P = NS). Conclusions: Open cell stents are associated with a larger mean particle size compared to closed cell stents. No impact on procedural outcomes based on stent type was observed. (J Vasc Surg 2012;56:89-95.)
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [21] Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis
    Ohki, T
    Roubin, GS
    Veith, FJ
    Iyer, SS
    Brady, E
    JOURNAL OF VASCULAR SURGERY, 1999, 30 (06) : 1034 - 1042
  • [22] Association between Plaque Echogenicity and Embolic Material Captured in Filter during Protected Carotid Angioplasty and Stenting
    Giannakopoulos, T. G.
    Moulakakis, K.
    Sfyroeras, G. S.
    Avgerinos, E. D.
    Antonopoulos, C. N.
    Kakisis, J. D.
    Karakitsos, P.
    Brountzos, E. N.
    Liapis, C. D.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (06) : 627 - 631
  • [23] In Reply: Carotid Artery Angioplasty and Stenting Without Distal Embolic Protection Devices
    Binning, Mandy J.
    Veznedaroglu, Erol
    NEUROSURGERY, 2017, 80 (06) : E274 - E274
  • [24] Haemodynamic depression during carotid angioplasty and stenting
    Widecka-Ostrowska, Katarzyna
    Modrzejewski, Andrzej
    Goracy, Jaroslaw
    POLISH JOURNAL OF RADIOLOGY, 2010, 75 (04) : 34 - 37
  • [25] Complication with an embolic protection device during carotid angioplasty
    Cardaioli, P
    Giordan, M
    Panfili, M
    Chioin, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (02) : 234 - 236
  • [26] Distal embolic protection during renal artery angioplasty and stenting
    Edwards, Matthew S.
    Craven, Brandon L.
    Stafford, Jeanette
    Craven, Timothy E.
    Sauve, Kenneth J.
    Ayerdi, Juan
    Geary, Randolph L.
    Hansen, Kimberley J.
    JOURNAL OF VASCULAR SURGERY, 2006, 44 (01) : 128 - 135
  • [27] Randomized clinical trial of open-cell vs closed-cell stents for carotid stenting and effects of stent design on cerebral embolization
    Timaran, Carlos H.
    Rosero, Eric B.
    Higuera, Adriana
    Ilarraza, Adriana
    Modrall, J. Gregory
    Clagett, G. Patrick
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (05) : 1310 - 1316
  • [28] Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis - Discussion
    Ouriel, K
    Ohki, T
    Madden, RE
    Dougherty, MJ
    Ascher, E
    JOURNAL OF VASCULAR SURGERY, 1999, 30 (06) : 1043 - 1044
  • [29] Carotid-artery stenting - Case open or closed?
    Furlan, Anthony J.
    NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (16): : 1726 - 1729
  • [30] Influence of stenting with open-cell stents vs close-cell stents on the outcomes of patients with bilateral carotid stenosis
    Lee, Han-Jui
    Chang, Feng-Chi
    Luo, Chao-Bao
    Guo, Wan-Yuo
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2019, 82 (01) : 66 - 71