An amperometric biosensor using Prussian blue modified electrode

被引:1
|
作者
Yi, In-Je [1 ]
Kim, Ju-Ho
Kang, C. J.
Park, Jaehyun
Kim, Yong-Sang
机构
[1] Myongji Univ, Dept Elect Engn, Gyeonggido 449728, South Korea
[2] Myongji Univ, Dept Phys, Gyeonggido 449728, South Korea
来源
关键词
Prussian blue; capillary electrophoresis; electrochemical detector;
D O I
10.4028/www.scientific.net/MSF.510-511.746
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The performances of an electrochemical detector (ECD) using Prussian blue (PB) modified indium tin oxide (ITO) electrode were investigated. PB is one of the well-known catalytic materials. PB offers electrocatalytic reaction between electrode and analytes (dopamine and catechol). We optimized the PB film thickness that would catalyze redox reaction efficiently using surface topography from atomic force microscopy (AFM). Capillary electrophoresis (CE) and amperometric method were used to separate and detect the testing analytes. The results showed that the PB film could serve as an excellent mediator, which catalyzes electron transfer. We measured electropherograms for the testing analytes consisting of catechol and dopamine with their concentrations of 100 wM and 10 mu M, respectively.
引用
收藏
页码:746 / 749
页数:4
相关论文
共 50 条
  • [41] Flow injection amperometric determination of pyridoxine at a Prussian blue nanoparticle-modified carbon ceramic electrode
    Razmi, H.
    Mohammad-Rezaei, R.
    ELECTROCHIMICA ACTA, 2010, 55 (05) : 1814 - 1819
  • [42] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a β-type zeolite modified electrode
    Liu, BH
    Liu, ZJ
    Chen, DD
    Kong, JL
    Deng, JQ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (06): : 539 - 544
  • [43] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a carbon nanotubes modified electrode
    Xu, JZ
    Zhu, JJ
    Wu, Q
    Hu, Z
    Chen, HY
    ELECTROANALYSIS, 2003, 15 (03) : 219 - 224
  • [44] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a β-type zeolite modified electrode
    Baohong Liu
    Zhenjiu Liu
    Dandan Chen
    Jilie Kong
    Jiaqi Deng
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 539 - 544
  • [45] Enhanced amperometric detection of bisphenol-A on sensitive Prussian blue modified indium tin oxide electrode
    Ha, Kon
    Yi, In-Je
    Joo, Gi-sung
    Lee, Hyun-Ho
    Kang, C. J.
    Kim, Yong-Sang
    JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2008, 11 (01) : 55 - 59
  • [46] A novel and improved surfactant-modified Prussian Blue electrode for amperometric detection of free chlorine in water
    Salazar, Pedro
    Martin, Miriam
    Garcia-Garcia, Francisco J.
    Luis Gonzalez-Mora, Jose
    Gonzalez-Elipe, Agustin R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 116 - 123
  • [47] Enhanced amperometric detection of bisphenol-A on sensitive Prussian Blue modified indium tin oxide electrode
    Dept. of Nano Science and Eng., Myongji Univ., Gyeonggi 449-728, Korea, Republic of
    不详
    J. New Mater. Electrochem. Syst., 2008, 1 (55-59):
  • [48] AMPEROMETRIC DETECTION OF CATECHOLAMINES WITH LIQUID-CHROMATOGRAPHY AT A NOVELLY CONSTRUCTED PRUSSIAN BLUE CHEMICALLY MODIFIED ELECTRODE
    ZHOU, JX
    WANG, E
    TALANTA, 1992, 39 (03) : 235 - 242
  • [49] Polyaniline/Prussian-Blue-Based Amperometric Biosensor for Detection of Uric Acid
    Thakur, Bhawana
    Sawant, Shilpa N.
    CHEMPLUSCHEM, 2013, 78 (02): : 166 - 174
  • [50] Electrochemical biosensor based on reduced graphene oxide modified electrode with Prussian blue and poly(toluidine blue O) coating
    Bai, Xiaoyun
    Chen, Guihua
    Shiu, Kwok-Keung
    ELECTROCHIMICA ACTA, 2013, 89 : 454 - 460