An amperometric biosensor using Prussian blue modified electrode

被引:1
|
作者
Yi, In-Je [1 ]
Kim, Ju-Ho
Kang, C. J.
Park, Jaehyun
Kim, Yong-Sang
机构
[1] Myongji Univ, Dept Elect Engn, Gyeonggido 449728, South Korea
[2] Myongji Univ, Dept Phys, Gyeonggido 449728, South Korea
来源
关键词
Prussian blue; capillary electrophoresis; electrochemical detector;
D O I
10.4028/www.scientific.net/MSF.510-511.746
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The performances of an electrochemical detector (ECD) using Prussian blue (PB) modified indium tin oxide (ITO) electrode were investigated. PB is one of the well-known catalytic materials. PB offers electrocatalytic reaction between electrode and analytes (dopamine and catechol). We optimized the PB film thickness that would catalyze redox reaction efficiently using surface topography from atomic force microscopy (AFM). Capillary electrophoresis (CE) and amperometric method were used to separate and detect the testing analytes. The results showed that the PB film could serve as an excellent mediator, which catalyzes electron transfer. We measured electropherograms for the testing analytes consisting of catechol and dopamine with their concentrations of 100 wM and 10 mu M, respectively.
引用
收藏
页码:746 / 749
页数:4
相关论文
共 50 条
  • [21] Development of an amperometric glucose biosensor based on the immobilization of glucose oxidase in an ormosil-PVA matrix onto a Prussian Blue modified electrode
    Chen HaiLing
    Zhao Li
    Chen Xi
    Zhuang ZhiXia
    Wang XiaoRu
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 2009, 52 (08): : 1128 - 1135
  • [22] Development of an amperometric glucose biosensor based on the immobilization of glucose oxidase in an ormosil-PVA matrix onto a Prussian Blue modified electrode
    HaiLing Chen
    Li Zhao
    Xi Chen
    ZhiXia Zhuang
    XiaoRu Wang
    Science in China Series B: Chemistry, 2009, 52 : 1128 - 1135
  • [23] Reagentless Amperometric Pyruvate Biosensor Based on a Prussian Blue- and Enzyme Nanoparticle-Modified Screen-Printed Carbon Electrode
    Thirumalai, Dinakaran
    Kim, Seonghye
    Kim, Suhkmann
    Chang, Seung-Cheol
    ACS OMEGA, 2020, 5 (46): : 30123 - 30129
  • [24] Development of an amperometric glucose biosensor based on the immobilization of glucose oxidase in an ormosil-PVA matrix onto a Prussian Blue modified electrode
    CHEN HaiLing1
    2 State Key Laboratory of Marine Environmental Science
    Science in China(Series B:Chemistry), 2009, (08) : 1128 - 1135
  • [25] Amperometric biosensor based on Prussian Blue nanoparticle-modified screen-printed electrode for estimation of glucose-6-phosphate
    Banerjee, Suchanda
    Sarkar, Priyabrata
    Turner, Anthony P. F.
    ANALYTICAL BIOCHEMISTRY, 2013, 439 (02) : 194 - 200
  • [26] An amperometric glucose biosensor based on poly(o-aminophenol) and Prussian blue films at platinum electrode
    Pan, DW
    Chen, JH
    Nie, LH
    Tao, WY
    Yao, SZ
    ANALYTICAL BIOCHEMISTRY, 2004, 324 (01) : 115 - 122
  • [27] Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode
    De Oliveira, MF
    Saczk, AA
    Neto, JAG
    Roldan, PS
    Stradiotto, NR
    SENSORS, 2003, 3 (09): : 371 - 380
  • [28] Flow injection amperometric determination of persulfate in cosmetic products using a Prussian Blue film-modified electrode
    De Oliveira, Marcelo F.
    Saczk, Adelir A.
    Neto, Jose A. Gomes
    Roldan, Paulo S.
    Stradiotto, Nelson R.
    Sensors, 2003, 3 (09) : 371 - 380
  • [29] Acetylcholinesterase biosensor based on prussian blue-modified electrode for detecting organophosphorous pesticides
    Sun, Xia
    Wang, Xiangyou
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (12): : 2611 - 2614
  • [30] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)