An amperometric biosensor using Prussian blue modified electrode

被引:1
|
作者
Yi, In-Je [1 ]
Kim, Ju-Ho
Kang, C. J.
Park, Jaehyun
Kim, Yong-Sang
机构
[1] Myongji Univ, Dept Elect Engn, Gyeonggido 449728, South Korea
[2] Myongji Univ, Dept Phys, Gyeonggido 449728, South Korea
来源
关键词
Prussian blue; capillary electrophoresis; electrochemical detector;
D O I
10.4028/www.scientific.net/MSF.510-511.746
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The performances of an electrochemical detector (ECD) using Prussian blue (PB) modified indium tin oxide (ITO) electrode were investigated. PB is one of the well-known catalytic materials. PB offers electrocatalytic reaction between electrode and analytes (dopamine and catechol). We optimized the PB film thickness that would catalyze redox reaction efficiently using surface topography from atomic force microscopy (AFM). Capillary electrophoresis (CE) and amperometric method were used to separate and detect the testing analytes. The results showed that the PB film could serve as an excellent mediator, which catalyzes electron transfer. We measured electropherograms for the testing analytes consisting of catechol and dopamine with their concentrations of 100 wM and 10 mu M, respectively.
引用
收藏
页码:746 / 749
页数:4
相关论文
共 50 条
  • [1] An amperometric cholesterol biosensor based on cholesterol oxidase immobilized in polypyrrole on a Prussian blue modified electrode
    Li, JP
    Peng, TZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 669 - 673
  • [2] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [3] Amperometric glucose biosensor with high sensitivity based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Zhang, Yannan
    Jin, Wanqin
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7490 - 7494
  • [4] Cholesterol biosensor based on platinium electrode modified by Prussian blue
    Wu, XQ
    Guo, XM
    Wang, R
    Zhang, ZR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (11) : 1273 - 1275
  • [5] A Prussian Blue Modified Electrode Based Amperometric Sensor for Lactate Determination
    Kuntawong, Parnpim
    Lertanantawong, Benchaporn
    Promptmas, Chamras
    2022 14TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2022), 2022,
  • [6] PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE
    KARYAKIN, AA
    GITELMACHER, OV
    KARYAKINA, EE
    ANALYTICAL CHEMISTRY, 1995, 67 (14) : 2419 - 2423
  • [7] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [8] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Ertek, Bensu
    Vu, Dai Long
    Cervenka, Libor
    Dilgin, Yusuf
    ANALYTICAL SCIENCES, 2012, 28 (11) : 1075 - 1080
  • [9] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Bensu Ertek
    Dai Long Vu
    Libor Červenka
    Yusuf Dilgin
    Analytical Sciences, 2012, 28 : 1075 - 1080
  • [10] Amperometric biosensor based on Prussian Blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    Rejeb, Ines Ben
    Arduini, Fabiana
    Amine, Aziz
    Gargouri, Mohamed
    Palleschi, Giuseppe
    ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 1 - 8