Visual Strehl Performance of IOL Designs with Extended Depth of Focus

被引:27
|
作者
Arias Gallego, Augusto [1 ,2 ]
Bara, Salvador [3 ]
Jaroszewicz, Zbigniew [4 ]
Kolodziejczyk, Andrzej [5 ]
机构
[1] Inst Tecnol Metropolitano, Res Ctr, Medellin 54954, Colombia
[2] Univ Nacl Colombia, Sch Phys, Medellin, Colombia
[3] Univ Santiago Compostela, EU Opt & Optometria, Area Opt, Galicia, Spain
[4] Inst Natl Telecommun, Inst Appl Opt, Warsaw, Poland
[5] Warsaw Univ Technol, Fac Phys, Warsaw, Poland
关键词
vision; presbyopia; intraocular lens; extended depth of focus; INTRAOCULAR-LENS IMPLANTATION; DIFFRACTIVE ELEMENTS; CATARACT-SURGERY; FOCAL DEPTH; QUALITY; ABERRATION; COMPENSATION; PRESBYOPIA; CONTRAST; METRICS;
D O I
10.1097/OPX.0b013e3182775e1a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The use of monofocal, bifocal, or multifocal intraocular lenses (IOLs) is a common option to restore the refractive power of the eye in aphakic patients after cataract surgery. In this article, we study the predicted performance of two new designs of IOL, both with extended depth of focus: the quartic axicon and the light sword optical element (LSOE). These elements provide continuous focal segments spanning the range of dioptric power required for presbyopia compensation. Methods. The performance analysis is based on the visual Strehl ratio (SR) computed in the spatial frequency domain, a neuro-optical quality metric that takes into account the effects of both the optical transfer function and the neural contrast sensitivity function. Furthermore, the classical SR and compound modulation transfer function were calculated. Some conventional transmittances of commercially available IOLs are also analyzed. Results. The LSOE design has a more homogeneous behavior than other available solutions, providing a more uniform image quality over a significant fraction of the required addition range. Conclusions. The angular average of the visual SR computed in the spatial frequency domain and compound modulation transfer function indicate that both designs of extended depth of focus elements provide better optical quality on the whole addition range, except at the end points, than the discrete focus designs. The LSOE performed better than the quartic axicon in terms of uniformity of image quality within the same range. (Optom Vis Sci 2012; 89: 1702-1707)
引用
收藏
页码:1702 / 1707
页数:6
相关论文
共 50 条
  • [41] Clinical evaluation of tolerance to residual refractive errors following implantation with a refractive extended depth of focus (EDF) IOL
    Vilupuru, Srividhya
    Alarcon, Aixa
    Tsai, Linda
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [42] Comparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens
    Moshirfar, Majid
    Ellis, James
    Beesley, Daniel
    McCabe, Shannon E.
    Lewis, Adam
    Jnr, William B. West
    Ronquillo, Yasmyne
    Snr, Phillip Hoopes
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 3051 - 3063
  • [43] Extended Depth of Focus Versus Monofocal IOLs: Objective and Subjective Visual Outcomes
    Pedrotti, Emilio
    Chierego, Chiara
    Talli, Pietro Maria
    Selvi, Federico
    Galzignato, Alice
    Neri, Enrico
    Barosco, Guido
    Montresor, Andrea
    Rodella, Anna
    Marchini, Giorgio
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (04) : 214 - +
  • [44] Visual outcomes of binocular implantation of a new extended depth of focus intraocular lens
    Sinha, Rajesh
    Sahay, Pranita
    Saxena, Rohit
    Kalra, Nidhi
    Gupta, Vinay
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (10) : 2111 - 2116
  • [45] Visual Performance, Subjective Satisfaction and Quality of Life Effect of a New Refractive Intraocular Lens with Central Extended Depth of Focus
    Gillmann, Kevin
    Mermoud, Andre
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (04) : 384 - 390
  • [46] Visual performance of prototype extended depth-of-focus contact lenses against contact lenses used for myopia control
    Diec, Jennie
    Sha, Jennifer
    Tilia, Daniel
    Jong, Monica
    Yeotikar, Nisha Shirish
    Thomas, Varghese
    Bakaraju, Ravi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [47] Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses
    Zhang, Yu
    Zhang, Jiaqing
    Liang, Chen
    Xu, Yifan
    Wu, Jiaying
    Wu, Junming
    Zhang, Yifan
    Jin, Aixia
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [48] Preoperative estimation of visual performance with IOL
    Kusel, R
    Rassow, B
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 215 (02) : 127 - 131
  • [49] Effect of Violet Light-Filtering and Manufacturing Improvements in an Extended Depth-of-Focus Intraocular Lens on Visual Performance
    van der Mooren, Marrie
    Alarcon, Aixa
    Sanchez, Mark D. Jenkins
    Chang, Daniel H.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 701 - 709
  • [50] Prediction accuracy of IOL calculation formulas using the ASCRS online calculator for a diffractive extended depth-of-focus IOL after myopic laser in situ keratomileusis
    Lwowski, Christoph
    Pawlowicz, Katarzyna
    Hinzelmann, Lisa
    Adas, Mahmoud
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (09): : 1240 - 1246