Visual Strehl Performance of IOL Designs with Extended Depth of Focus

被引:27
|
作者
Arias Gallego, Augusto [1 ,2 ]
Bara, Salvador [3 ]
Jaroszewicz, Zbigniew [4 ]
Kolodziejczyk, Andrzej [5 ]
机构
[1] Inst Tecnol Metropolitano, Res Ctr, Medellin 54954, Colombia
[2] Univ Nacl Colombia, Sch Phys, Medellin, Colombia
[3] Univ Santiago Compostela, EU Opt & Optometria, Area Opt, Galicia, Spain
[4] Inst Natl Telecommun, Inst Appl Opt, Warsaw, Poland
[5] Warsaw Univ Technol, Fac Phys, Warsaw, Poland
关键词
vision; presbyopia; intraocular lens; extended depth of focus; INTRAOCULAR-LENS IMPLANTATION; DIFFRACTIVE ELEMENTS; CATARACT-SURGERY; FOCAL DEPTH; QUALITY; ABERRATION; COMPENSATION; PRESBYOPIA; CONTRAST; METRICS;
D O I
10.1097/OPX.0b013e3182775e1a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The use of monofocal, bifocal, or multifocal intraocular lenses (IOLs) is a common option to restore the refractive power of the eye in aphakic patients after cataract surgery. In this article, we study the predicted performance of two new designs of IOL, both with extended depth of focus: the quartic axicon and the light sword optical element (LSOE). These elements provide continuous focal segments spanning the range of dioptric power required for presbyopia compensation. Methods. The performance analysis is based on the visual Strehl ratio (SR) computed in the spatial frequency domain, a neuro-optical quality metric that takes into account the effects of both the optical transfer function and the neural contrast sensitivity function. Furthermore, the classical SR and compound modulation transfer function were calculated. Some conventional transmittances of commercially available IOLs are also analyzed. Results. The LSOE design has a more homogeneous behavior than other available solutions, providing a more uniform image quality over a significant fraction of the required addition range. Conclusions. The angular average of the visual SR computed in the spatial frequency domain and compound modulation transfer function indicate that both designs of extended depth of focus elements provide better optical quality on the whole addition range, except at the end points, than the discrete focus designs. The LSOE performed better than the quartic axicon in terms of uniformity of image quality within the same range. (Optom Vis Sci 2012; 89: 1702-1707)
引用
收藏
页码:1702 / 1707
页数:6
相关论文
共 50 条
  • [31] Visual performance and positional stability of a capsulorhexis-fixated extended depth-of-focus intraocular lens
    Darian-Smith, Erica
    Versace, Patrick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 179 - 187
  • [32] Visual Performance of Non-Diffractive Extended Depth of Focus and Neutral Aspheric Monofocal Intraocular Lenses
    O'Rourke, Tara
    Pantanelli, Seth
    Bolognia, Olga
    Longenecker, Amy
    Lehman, Erik
    Scruggs, Kathleen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [33] Comparative Evaluation of Visual Performance and Patient Satisfaction following Cataract Surgery: A Retrospective Analysis of an Extended Depth-of-Focus Intraocular Lens and a Diffractive Multifocal Lens with Extended Depth of Focus
    Han, Kwang Eon
    Lee, Ji Eun
    Mizota, Atsushi
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [34] Clinical Outcomes of a Non-Diffractive Extended Depth-of-Focus IOL in Eyes with Mild Glaucoma
    Ferguson, Tanner J.
    Wilson, Caroline W.
    Shafer, Brian M.
    Berdahl, John P.
    Terveen, Daniel C.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 861 - 868
  • [35] Influence of extended depth of focus intraocular lenses on visual field sensitivity
    Takahashi, Makiko
    Yamashiro, Chiemi
    Yoshimoto, Takuya
    Kobayashi, Yuka
    Higashijima, Fumiaki
    Kobayashi, Masaaki
    Hatano, Makoto
    Ohta, Manami
    Nagai, Tomohiko
    Teranishi, Shinichiro
    Suzuki, Katsuyoshi
    Takabatake, Ryu
    Kimura, Kazuhiro
    PLOS ONE, 2020, 15 (09):
  • [36] Visual performance with an extended depth of focus contact lens for myopia control and corneal topography in assessing lens centration
    Rizzo, G. C.
    Borghesi, A.
    Di Vizio, A.
    Zeri, F.
    Ponzini, E.
    Tavazzi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2023, 46 (05):
  • [37] Visual Performance and Patient Satisfaction of Bilaterally Implanted Extended Depth of Focus Intraocular Lens: Outcomes of a Multicenter Registry
    Howes, Frank
    Rementeria-Capelo, Laureano A.
    Poyales, Francisco
    Borovik, Armand
    Khoramnia, Ramin
    Perez-Vives, Caridad
    Nuijts, Rudy M. M. A.
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02)
  • [38] Visual Performance After Unilateral Implantation of an Extended Depth-of-Focus Intraocular Lens in Patients With Unilateral Cataract
    Nowrouzi, Ali
    del Barrio, Jorge L. Alio
    D'Oria, Francesco
    Kamel, Nabil Ragaei
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (08) : 518 - +
  • [39] Clinical Evaluation of Violet Light Filtration and High-Resolution Lathing on a Diffractive Extended Depth of Focus IOL
    Chang, Daniel H.
    Kao, Andrew A.
    Huggins, Laura K.
    Albert, Jacqueline N.
    Whinery, Jacqueline N.
    Camirand, Brittany M.
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (12) : 3135 - 3147
  • [40] Visual performance and binocular vision function in adults wearing prototype extended depth-of-focus contact lenses
    Sha, Jennifer
    Tilia, Daniel
    Amrizal, Hamdy
    Yeotikar, Nisha
    Thomas, Varghese
    Bakaraju, Ravi Chandra