A Systematic Analysis of IMRT QA Results

被引:0
|
作者
Su, Zhong [2 ]
Fox, Christopher [2 ]
Li, Haisen [2 ]
Jin, Hosang [3 ]
Chung, Heeteak [3 ]
Yang, Huey [2 ]
Li, Jonathan [2 ]
Liu, Chihray [2 ]
Palta, Jatinder [2 ]
Kim, Siyong [1 ,2 ]
机构
[1] Univ Florida, 2000 SW Archer Rd, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 | 2007年 / 14卷
关键词
IMRT; QA; Diode Array; Multi-leaf Collimator;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A commercial 2-D diode array (Mapcheck, Sun Nuclear) has been used for IMRT plan QA at the University of Florida. By retrospectively reviewing the QA data we have systematically evaluated factors that influence quantitative differences between calculation and measurement. For each field, a planar dose was calculated using Philips Pinnacle treatment planning system (TPS) at 10 cm depth, 100 cm SAD in solid water with normal incidence of the gantry and Mapcheck measurement was performed as planned. Absolute dose comparison was made between the calculated and measured with a 3 % and 3 mm criteria. A threshold was set at 10 % of normalization point dose. The pass rates were categorized into the versions of the TPS and IMRT delivery system. We also analyzed the outliers to see if we could a priori predict the differences between measured and calculated using a recently introduced dose uncertainty model (Medical Physics 2005, pp 1747). A total of 417 plans with 2210 beams were analyzed; 57.4 % of all beams had pass rates of at least 95 %; 36.2 % were between 85 % and 95 %; 6.4 % were below 85 %. The pass rate correlated strongly with the accuracy of beam modeling in TPS. With explicit modeling of MLC (e.g., MLC leaf-end and leaf-side effects), the TPS showed a better pass rate (60.3 % vs. 52.7 % in percent of having more than 95 % pass rate). The failure rate increased with the complexity of intensity-modulation. It also increased with the larger uncertainty of MLC beam model. In conclusion, the accuracy of IMRT delivery is strongly correlated to the accuracy of MLC beam model in TPS. The pass rate for patient specific QA is strongly influenced by the complexity of the intensity modulation in a field.
引用
收藏
页码:1815 / +
页数:2
相关论文
共 50 条
  • [31] A National QA Audit of QA Systems Used for IMRT and VMAT Patient QA
    Seravalli, E.
    Houweling, A.
    Van Gellekom, M.
    Kaas, J.
    Kuik, M.
    Loeff, E.
    Raaben, T.
    De Pooter, J.
    de Vries, W.
    Van de Kamer, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3342 - 3342
  • [32] The Utilization of a Head-And-Neck IMRT QA Benchmark to Identify the Cause of Individual Imrt Qa Failure
    Gao, Z.
    Cheng, C.
    Wu, G.
    Li, M.
    MEDICAL PHYSICS, 2011, 38 (06) : 3542 - U43
  • [33] QA for linacs and MLC used for IMRT
    Xia, P.
    MEDICAL PHYSICS, 2007, 34 (06) : 2539 - 2539
  • [34] Patient-based QA for IMRT
    Verellen, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1836 - 1837
  • [35] On the new metrics for IMRT QA verification
    Garcia-Romero, Alejandro
    Hernandez-Vitoria, Araceli
    Millan-Cebrian, Esther
    Alba-Escorihuela, Veronica
    Serrano-Zabaleta, Sonia
    Ortega-Pardina, Pablo
    MEDICAL PHYSICS, 2016, 43 (11) : 6058 - 6071
  • [36] Closing the Loop On Virtual IMRT QA
    Valdes, G.
    Scheuermann, R.
    Y, H. C.
    Olszanski, A.
    Bellerive, M.
    Solberg, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3192 - 3192
  • [37] A national QA audit for IMRT and VMAT
    Seravalli, E.
    Houweling, A. C.
    Van Gellekom, M. P. R.
    Kaas, J.
    Kuik, M.
    Loeff, E.
    Raaben, T. A.
    De Pooter, J. A.
    De Vries, J. H. W.
    Van de Kamer, J. B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S852 - S853
  • [38] Breaking bad IMRT QA practice
    Stojadinovic, Strahinja
    Ouyang, Luo
    Gu, Xuejun
    Pompos, Arnold
    Bao, Qinan
    Solberg, Timothy D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 154 - 165
  • [39] Development of a piratical IMRT QA system
    Cho, S
    Yi, B
    Ahn, S
    Kim, J
    Kwon, S
    Choi, E
    MEDICAL PHYSICS, 2002, 29 (06) : 1264 - 1264
  • [40] A diode array device for QA of IMRT
    Sorensen, S
    Hugo, G
    Tenn, S
    Agazaryan, N
    Ullrich, W
    MEDICAL PHYSICS, 2003, 30 (06) : 1351 - 1351