A Systematic Analysis of IMRT QA Results

被引:0
|
作者
Su, Zhong [2 ]
Fox, Christopher [2 ]
Li, Haisen [2 ]
Jin, Hosang [3 ]
Chung, Heeteak [3 ]
Yang, Huey [2 ]
Li, Jonathan [2 ]
Liu, Chihray [2 ]
Palta, Jatinder [2 ]
Kim, Siyong [1 ,2 ]
机构
[1] Univ Florida, 2000 SW Archer Rd, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
关键词
IMRT; QA; Diode Array; Multi-leaf Collimator;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A commercial 2-D diode array (Mapcheck, Sun Nuclear) has been used for IMRT plan QA at the University of Florida. By retrospectively reviewing the QA data we have systematically evaluated factors that influence quantitative differences between calculation and measurement. For each field, a planar dose was calculated using Philips Pinnacle treatment planning system (TPS) at 10 cm depth, 100 cm SAD in solid water with normal incidence of the gantry and Mapcheck measurement was performed as planned. Absolute dose comparison was made between the calculated and measured with a 3 % and 3 mm criteria. A threshold was set at 10 % of normalization point dose. The pass rates were categorized into the versions of the TPS and IMRT delivery system. We also analyzed the outliers to see if we could a priori predict the differences between measured and calculated using a recently introduced dose uncertainty model (Medical Physics 2005, pp 1747). A total of 417 plans with 2210 beams were analyzed; 57.4 % of all beams had pass rates of at least 95 %; 36.2 % were between 85 % and 95 %; 6.4 % were below 85 %. The pass rate correlated strongly with the accuracy of beam modeling in TPS. With explicit modeling of MLC (e.g., MLC leaf-end and leaf-side effects), the TPS showed a better pass rate (60.3 % vs. 52.7 % in percent of having more than 95 % pass rate). The failure rate increased with the complexity of intensity-modulation. It also increased with the larger uncertainty of MLC beam model. In conclusion, the accuracy of IMRT delivery is strongly correlated to the accuracy of MLC beam model in TPS. The pass rate for patient specific QA is strongly influenced by the complexity of the intensity modulation in a field.
引用
收藏
页码:1815 / +
页数:2
相关论文
共 50 条
  • [21] Action levels for IMRT QA
    Palta, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2157 - 2157
  • [22] QA of IMRT - the American practice
    Ezzell, G
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S123 - S123
  • [23] MC based QA of IMRT
    Spezi, E
    Lewis, DG
    Millin, AE
    Cuffin, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S46 - S46
  • [24] IMRT: QA - What is enough?
    Low, D
    Kinsey, C
    LoSasso, T
    Salter, B
    MEDICAL PHYSICS, 2003, 30 (06) : 1434 - 1434
  • [25] Emerging Frontiers in IMRT QA
    Siebers, J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [26] Multi-institutional retrospective analysis of IMRT QA measurements
    Sontag, M
    Chen, X
    Qin, L
    Ottino, F
    Chen, H
    Li, F
    Loper, A
    Komanduri, K
    Lalonde, R
    Yue, N
    Heron, D
    Huq, M
    MEDICAL PHYSICS, 2005, 32 (06) : 1985 - 1986
  • [27] Analysis of the correlation between MLC file parameters and IMRT QA
    Kirk, M
    Chu, J
    Zhang, Y
    MEDICAL PHYSICS, 2005, 32 (06) : 1980 - 1980
  • [28] Explainable Machine Learning IMRT QA Triage Prediction Models for Selective IMRT QA Measurement
    Adam, D. P.
    He, K.
    Peng, Y.
    Hooshangnejad, H.
    Farjam, R.
    Ding, K.
    Qin, A.
    Shen, B.
    Miles, D. A.
    Huang, E.
    Atkins, G.
    Marsh, I. R.
    Bell, L.
    Su, L.
    Kania, N. R.
    Jia, X.
    Liu, A.
    Han-Oh, S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7670 - 7670
  • [29] Effects of spatial resolution and noise on gamma analysis for IMRT QA
    Huang, Jessie Y.
    Pulliam, Kiley B.
    McKenzie, Elizabeth M.
    Followill, David S.
    Kry, Stephen F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 93 - 104
  • [30] Process control analysis of IMRT QA: implications for clinical trials
    Pawlicki, Todd
    Yoo, Sua
    Court, Laurence E.
    McMillan, Sharon K.
    Rice, Roger K.
    Russell, J. Donald
    Pacyniak, John M.
    Woo, Milton K.
    Basran, Parminder S.
    Boyer, Arthur L.
    Bonilla, Claribel
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (18): : 5193 - 5205