A Systematic Analysis of IMRT QA Results

被引:0
|
作者
Su, Zhong [2 ]
Fox, Christopher [2 ]
Li, Haisen [2 ]
Jin, Hosang [3 ]
Chung, Heeteak [3 ]
Yang, Huey [2 ]
Li, Jonathan [2 ]
Liu, Chihray [2 ]
Palta, Jatinder [2 ]
Kim, Siyong [1 ,2 ]
机构
[1] Univ Florida, 2000 SW Archer Rd, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
关键词
IMRT; QA; Diode Array; Multi-leaf Collimator;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A commercial 2-D diode array (Mapcheck, Sun Nuclear) has been used for IMRT plan QA at the University of Florida. By retrospectively reviewing the QA data we have systematically evaluated factors that influence quantitative differences between calculation and measurement. For each field, a planar dose was calculated using Philips Pinnacle treatment planning system (TPS) at 10 cm depth, 100 cm SAD in solid water with normal incidence of the gantry and Mapcheck measurement was performed as planned. Absolute dose comparison was made between the calculated and measured with a 3 % and 3 mm criteria. A threshold was set at 10 % of normalization point dose. The pass rates were categorized into the versions of the TPS and IMRT delivery system. We also analyzed the outliers to see if we could a priori predict the differences between measured and calculated using a recently introduced dose uncertainty model (Medical Physics 2005, pp 1747). A total of 417 plans with 2210 beams were analyzed; 57.4 % of all beams had pass rates of at least 95 %; 36.2 % were between 85 % and 95 %; 6.4 % were below 85 %. The pass rate correlated strongly with the accuracy of beam modeling in TPS. With explicit modeling of MLC (e.g., MLC leaf-end and leaf-side effects), the TPS showed a better pass rate (60.3 % vs. 52.7 % in percent of having more than 95 % pass rate). The failure rate increased with the complexity of intensity-modulation. It also increased with the larger uncertainty of MLC beam model. In conclusion, the accuracy of IMRT delivery is strongly correlated to the accuracy of MLC beam model in TPS. The pass rate for patient specific QA is strongly influenced by the complexity of the intensity modulation in a field.
引用
收藏
页码:1815 / +
页数:2
相关论文
共 50 条
  • [1] A systematic analysis of patient specific IMRT QA data
    Su, Z.
    Jin, H.
    Fox, C.
    Li, H.
    Lynch, B.
    Yang, C.
    Li, J.
    Liu, C.
    Palta, J.
    Kim, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2291 - 2291
  • [2] Analysis of the results of QA for individual IMRT treatment plans
    Lliso, F.
    Perez-Calatayud, J.
    Carmona, V.
    Gimeno, J.
    Ballester, F.
    Gonzalez, V.
    Granero, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S184 - S184
  • [3] A survey on planar IMRT QA analysis
    Nelms, Benjamin E.
    Simon, Jeff A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 76 - 90
  • [4] Results of a national audit of IMRT and VMAT patient QA
    Seravalli, E.
    Houweling, A. C.
    Van Gellekom, M. P. R.
    Kaas, J.
    Kuik, M.
    Loeff, E. A.
    Raaben, T. A.
    De Pooter, J. A.
    De Vries, J. H. W.
    Van de Kamer, J. B.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S259 - S260
  • [5] A Novel Method for Further Analysis of IMRT QA
    Lawrence, M.
    Cullip, T.
    Potter, L.
    Lian, J.
    Wang, S.
    Xu, Z.
    Deschesne, K.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3233 - +
  • [6] IMRT patient QA
    Ramsey, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2270 - 2270
  • [7] Tools for IMRT QA
    Dogan, N
    MEDICAL PHYSICS, 2005, 32 (06) : 2117 - 2117
  • [8] MC as QA for IMRT
    Francescon, P
    Cora, S
    Chiovati, P
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S46 - S46
  • [9] A New 3D Gamma Analysis Algorithm for Better VMAT/IMRT QA Results
    Cao, D.
    Ye, J.
    Shepard, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 334 - 334
  • [10] Use of dose gradient maps for IMRT QA analysis
    Moran, JM
    Radawski, J
    Fraass, BA
    MEDICAL PHYSICS, 2003, 30 (06) : 1396 - 1396