Maximizing Protection by Minimizing Arcing Times in Medium-Voltage Systems

被引:22
|
作者
Kay, John A. [1 ]
Kumpulainen, Lauri [2 ]
机构
[1] Rockwell Automat, Cambridge, ON N1R 5X1, Canada
[2] Oy Merinova Ab, Vaasa 65101, Finland
关键词
Arc eliminator; arc fault; arc flash; arc-flash mitigation; current-limiting fuses; forest products; incident energy; pressure wave; FUSES;
D O I
10.1109/TIA.2013.2255253
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Arcing faults in the forest product industries are real risks that often lead to severe injuries and fires. From an economic point of view, the consequences due to direct and indirect costs can be extremely high as well. There are various opportunities to prevent arcing faults, but faults cannot be totally eliminated. This is why several approaches to mitigate the consequences of arcing faults have been introduced, particularly in the last decade. Several manufacturers have started to produce arc-flash protection relays based on optical detection of light energy from an arc event. In most applications, the light information is confirmed by overcurrent information before a trip command is initiated to an upstream current-breaking device. The tripping of a circuit breaker, for instance, occurs in only a few milliseconds. In most cases, this seems to be the state-of-the-art technology leading to very reasonable incident energy levels. However, it is essential to be able to minimize not only the thermal impact but also the pressure wave. This paper investigates technology aimed at maximizing the protection for the pressure wave.
引用
收藏
页码:1920 / 1927
页数:8
相关论文
共 50 条
  • [21] Problems Associated with the Protection of a Medium-Voltage Urban Network.
    Thevenaz, R.
    Bulletin de l'Association Suisse des Electriciens, 1975, 66 (23): : 1298 - 1303
  • [22] MEDIUM-VOLTAGE DRIVES
    Hiller, Marc
    Sommer, Rainer
    Beuermann, Max
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2010, 16 (02) : 22 - 30
  • [23] Optimal Selection and Location of BESS Systems in Medium-Voltage Rural Distribution Networks for Minimizing Greenhouse Gas Emissions
    Montoya, Oscar Danilo
    Gil-Gonzalez, Walter
    Hernandez, Jesus C.
    ELECTRONICS, 2020, 9 (12) : 1 - 15
  • [24] COMPACT STATIONS INCREASE CAPACITY OF MEDIUM-VOLTAGE SYSTEMS
    ZINK, H
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1973, 25 (20): : 551 - &
  • [25] Resonance Overvoltages in Medium-Voltage Multilevel Drive Systems
    Endrejat, Frieder
    Pillay, Pragasen
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (04) : 1199 - 1209
  • [26] AUTOMATION AND CONTROL SYSTEMS FOR MEDIUM-VOLTAGE SUBSTATIONS.
    Kopainsky, J.
    Ungrad, H.
    Vector (Electrical Engineering), 1985, : 16 - 17
  • [27] Medium-voltage power conversion systems in the next generation
    Akagi, Hirofumi
    Inoue, Shigenori
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 23 - +
  • [28] VACUUM CIRCUIT-BREAKERS IN MEDIUM-VOLTAGE SYSTEMS
    FINK, H
    VAKUUM-TECHNIK, 1987, 36 (04): : 118 - 125
  • [29] FAULT INDICATORS OF PARTIAL DISCHARGES IN MEDIUM-VOLTAGE SYSTEMS
    Hamacek, Stefan
    Misak, Stanislav
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2013, 11 (04) : 284 - 289
  • [30] CALCULATING THE MAXIMUM TRANSMISSION CAPACITY OF MEDIUM-VOLTAGE SYSTEMS
    HAUSDORF, D
    ENERGIETECHNIK, 1979, 29 (08): : 309 - 313