Maximizing Protection by Minimizing Arcing Times in Medium-Voltage Systems

被引:22
|
作者
Kay, John A. [1 ]
Kumpulainen, Lauri [2 ]
机构
[1] Rockwell Automat, Cambridge, ON N1R 5X1, Canada
[2] Oy Merinova Ab, Vaasa 65101, Finland
关键词
Arc eliminator; arc fault; arc flash; arc-flash mitigation; current-limiting fuses; forest products; incident energy; pressure wave; FUSES;
D O I
10.1109/TIA.2013.2255253
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Arcing faults in the forest product industries are real risks that often lead to severe injuries and fires. From an economic point of view, the consequences due to direct and indirect costs can be extremely high as well. There are various opportunities to prevent arcing faults, but faults cannot be totally eliminated. This is why several approaches to mitigate the consequences of arcing faults have been introduced, particularly in the last decade. Several manufacturers have started to produce arc-flash protection relays based on optical detection of light energy from an arc event. In most applications, the light information is confirmed by overcurrent information before a trip command is initiated to an upstream current-breaking device. The tripping of a circuit breaker, for instance, occurs in only a few milliseconds. In most cases, this seems to be the state-of-the-art technology leading to very reasonable incident energy levels. However, it is essential to be able to minimize not only the thermal impact but also the pressure wave. This paper investigates technology aimed at maximizing the protection for the pressure wave.
引用
收藏
页码:1920 / 1927
页数:8
相关论文
共 50 条
  • [11] Challenges in Protection of Converter Dominated Medium-Voltage Microgrids
    Mohanty, Rabindra
    Chen, Peiyuan
    Le Anh Tuan
    Narula, Anant
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [12] Improving Relay Protection Levels in Medium-Voltage Switchgear
    Catlett, Raymond
    Martin, Donald
    Wilson, Robert A.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (03) : 1630 - 1638
  • [13] Model-Based General Arcing Fault Detection in Medium-Voltage Distribution Lines
    Zhang, Wenhai
    Jing, Yindi
    Xiao, Xianyong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (05) : 2231 - 2241
  • [14] Modeling of Medium-voltage Overland Systems.
    Messager, P.
    Electricite de France, Bulletin de la Direction des Etudes et Recherches, Serie B: Reseaux Electriques, Materiels Electriques, 1980, (02): : 25 - 53
  • [15] How to design medium-voltage distribution systems
    Mohammed, Taha
    Magsipoc, Robert
    Consulting-Specifying Engineer, 2023, 60 (05): : 42 - 47
  • [16] Power cable fired by transient arcing below the action value of relay protection: An analysis of a medium-voltage cable joint breakdown fault
    Hu, Ran
    Liu, Gang
    Huang, Chenglong
    Xu, Zhifeng
    Zhou, Wenqing
    ENGINEERING FAILURE ANALYSIS, 2023, 145
  • [17] Comparative Amplitude Grounding Protection of Medium-Voltage Lines.
    Rabiega, R.
    1600, (50):
  • [18] A new wireless communication platform for medium-voltage protection and control
    Thonet, G
    Deck, BR
    WFCS 2004: IEEE INTERNATIONAL WORKSHOP ON FACTORY COMMUNICATION SYSTEMS, PROCEEDINGS, 2004, : 335 - 338
  • [19] Combined Protection and Control Equipment for Applications in the Medium-Voltage Area
    Dobriceanu, M.
    Bitoleanu, A.
    Popescu, M.
    Subtirelu, E.
    Enache, S.
    2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2008, : 860 - 865
  • [20] Strategies for mitigating the effects of internal arcing faults in medium-voltage metal-enclosed switchgear
    Wactor, M
    Olsen, TW
    Ball, CJ
    Lemmerman, DJ
    Puckett, RJ
    Zawadzki, J
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 323 - 328