Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter

被引:6
|
作者
Mace, E. K. [1 ]
Aalseth, C. E. [1 ]
Bonicalzi, R. M. [1 ]
Day, A. R. [1 ]
Hoppe, E. W. [1 ]
Keillor, M. E. [1 ]
Myers, A. W. [1 ]
Overman, C. T. [1 ]
Seifert, A. [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
美国能源部;
关键词
Ultra-low-background; Microdischarge; Proportional counter; Low noise;
D O I
10.1007/s10967-012-2042-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of similar to 30 m water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through similar to 1 m of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 50 条
  • [31] LOW-BACKGROUND PROPORTIONAL RESONANCE COUNTER FOR MOSSBAUER STUDIES.
    Medvedeva, N.S.
    Somov, V.N.
    Korytko, L.A.
    Tolstikov, A.N.
    Toshchakov, E.K.
    Sozinov, V.A.
    Instruments and experimental techniques New York, 1981, 24 (1 pt 1): : 49 - 52
  • [32] REPORT ON THE DEVELOPMENT OF A LOW BACKGROUND PROPORTIONAL COUNTER FOR MONITORING PLUTONIUM IN THE LUNG
    LEAKE, JW
    SMITH, A
    TURNER, MJL
    WHITE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (03): : 589 - 596
  • [33] Rapid signal acquisition for low-rate carrier-based ultra-wideband impulse radio
    Fujiwara, R
    Shida, M
    Maeki, A
    Mizugaki, K
    Kokubo, M
    Miyazaki, M
    2005 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), VOLS 1-6, CONFERENCE PROCEEDINGS, 2005, : 4497 - 4500
  • [34] Signal processing for cochlear implants and low-rate speech coding
    Loizou, PC
    2000 IEEE WORKSHOP ON SPEECH CODING, PROCEEDINGS: MEETING THE CHALLENGES OF THE NEW MILLENNIUM, 2000, : 68 - 68
  • [35] A large HPGe detector for the non-destructive radioassay of an ultra-low-background counting facility
    Fechner, M.
    Henson, C.
    Gaffiot, J.
    Lasserre, T.
    Letourneau, A.
    Lhuillier, D.
    Mention, G.
    Mueller, Th A.
    Queval, R.
    Svoboda, R.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (07) : 1033 - 1038
  • [36] Design and construction of a low-background, internal-source proportional counter
    Craig E. Aalseth
    Anthony R. Day
    Eric W. Hoppe
    Todd W. Hossbach
    Brian J. Hyronimus
    Martin E. Keillor
    Kevin E. Litke
    Esther E. Mintzer
    Allen Seifert
    Glen A. Warren
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 233 - 237
  • [37] Shielding concepts for low-background proportional counter arrays in surface laboratories
    Aalseth, C. E.
    Humble, P. H.
    Mace, E. K.
    Orrell, J. L.
    Seifert, A.
    Williams, R. M.
    APPLIED RADIATION AND ISOTOPES, 2016, 108 : 92 - 99
  • [38] Design and construction of a low-background, internal-source proportional counter
    Aalseth, Craig E.
    Day, Anthony R.
    Hoppe, Eric W.
    Hossbach, Todd W.
    Hyronimus, Brian J.
    Keillor, Martin E.
    Litke, Kevin E.
    Mintzer, Esther E.
    Seifert, Allen
    Warren, Glen A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (01) : 233 - 237
  • [39] Low-rate TCP-targeted denial of service attacks and counter strategies
    Kuzmanovic, Aleksandar
    Knightly, Edward W.
    IEEE-ACM TRANSACTIONS ON NETWORKING, 2006, 14 (04) : 683 - 696
  • [40] Indigenous Design and Development of Gated Photon Counter for Low-Rate Photon Regime
    Rashtrapriya Kumar Kapri
    Parag Sharma
    P. K. Dubey
    MAPAN, 2021, 36 : 59 - 66