Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter

被引:6
|
作者
Mace, E. K. [1 ]
Aalseth, C. E. [1 ]
Bonicalzi, R. M. [1 ]
Day, A. R. [1 ]
Hoppe, E. W. [1 ]
Keillor, M. E. [1 ]
Myers, A. W. [1 ]
Overman, C. T. [1 ]
Seifert, A. [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
美国能源部;
关键词
Ultra-low-background; Microdischarge; Proportional counter; Low noise;
D O I
10.1007/s10967-012-2042-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of similar to 30 m water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through similar to 1 m of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 50 条
  • [21] Methods for using argon-39 to age-date groundwater using ultra-low-background proportional counting
    Mace, Emily
    Aalseth, Craig
    Brandenberger, Jill
    Day, Anthony
    Hoppe, Eric
    Humble, Paul
    Keillor, Martin
    Kulongoski, Justin
    Overman, Cory
    Panisko, Mark
    Seifert, Allen
    White, Signe
    Freeburg, Eric Wilcox
    Williams, Richard
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 9 - 12
  • [22] Low-rate signal compression incorporating decimation
    Ramstad, Tor A.
    2006 7TH NORDIC SIGNAL PROCESSING SYMPOSIUM, 2006, : 274 - 277
  • [23] Digital pulse-shape discrimination applied to an ultra-low-background gas-proportional counting system: first results
    C. E. Aalseth
    A. R. Day
    E. S. Fuller
    E. W. Hoppe
    M. E. Keillor
    E. K. Mace
    A. W. Myers
    C. T. Overman
    M. E. Panisko
    A. Seifert
    G. A. Warren
    R. M. Williams
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 823 - 827
  • [24] Digital pulse-shape discrimination applied to an ultra-low-background gas-proportional counting system: first results
    Aalseth, C. E.
    Day, A. R.
    Fuller, E. S.
    Hoppe, E. W.
    Keillor, M. E.
    Mace, E. K.
    Myers, A. W.
    Overman, C. T.
    Panisko, M. E.
    Seifert, A.
    Warren, G. A.
    Williams, R. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) : 823 - 827
  • [25] LOW-BACKGROUND PROPORTIONAL RESONANCE COUNTER FOR MOSSBAUER STUDIES
    MEDVEDEVA, NS
    SOMOV, VN
    KORYTKO, LA
    TOLSTIKOV, AN
    TOSHCHAKOV, EK
    SOZINOV, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (01) : 49 - 52
  • [26] CHARACTERISTICS OF A HIGH-PRESSURE, LOW BACKGROUND PROPORTIONAL COUNTER
    KUZMINOV, VV
    NOVIKOV, VM
    PRITICHENKO, BV
    POMANSKY, AA
    POVINEC, P
    JANIK, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 17 (5-6): : 452 - 453
  • [27] CASCADES: An Ultra-Low-Background Germanium Crystal Array at Pacific Northwest National Laboratory
    Keillor, M. E.
    Aalseth, C. E.
    Day, A. R.
    Erikson, L. E.
    Fast, J. E.
    Glasgow, B. D.
    Hoppe, E. W.
    Hossbach, T. W.
    Hyronimus, B. J.
    Miley, H. S.
    Myers, A. W.
    Seifert, A.
    Stavenger, T. J.
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [28] Background characterization of an ultra-low background liquid scintillation counter
    Erchinger, J. L.
    Orrell, J. L.
    Aalseth, C. E.
    Bernacki, B. E.
    Douglas, M.
    Fuller, E. S.
    Keillor, M. E.
    Marianno, C. M.
    Morley, S. M.
    Mullen, C. A.
    Panisko, M. E.
    Warren, G. A.
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 168 - 170
  • [29] Choosing the amplitude interval for a proportional counter at a low signal level
    P. S. Antsiferov
    Technical Physics, 1998, 43 : 596 - 597
  • [30] Choosing the amplitude interval for a proportional counter at a low signal level
    Antsiferov, PS
    TECHNICAL PHYSICS, 1998, 43 (05) : 596 - 597