Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter

被引:6
|
作者
Mace, E. K. [1 ]
Aalseth, C. E. [1 ]
Bonicalzi, R. M. [1 ]
Day, A. R. [1 ]
Hoppe, E. W. [1 ]
Keillor, M. E. [1 ]
Myers, A. W. [1 ]
Overman, C. T. [1 ]
Seifert, A. [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
美国能源部;
关键词
Ultra-low-background; Microdischarge; Proportional counter; Low noise;
D O I
10.1007/s10967-012-2042-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of similar to 30 m water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through similar to 1 m of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 50 条
  • [1] Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter
    E. K. Mace
    C. E. Aalseth
    R. M. Bonicalzi
    A. R. Day
    E. W. Hoppe
    M. E. Keillor
    A. W. Myers
    C. T. Overman
    A. Seifert
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 753 - 758
  • [2] Simulations of electron avalanches in an ultra-low-background proportional counter
    Robinson, John W.
    Aalseth, Craig
    Dion, Michael P.
    Overman, Cory
    Seifert, Allen
    VanDevender, Brent
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 810 : 37 - 43
  • [3] Calibration of an Ultra-Low-Background Proportional Counter for Measuring 37Ar
    Seifert, A.
    Aalseth, C. E.
    Bonicalzi, R. M.
    Bowyer, T. W.
    Day, A. R.
    Fuller, E. S.
    Haas, D. A.
    Hayes, J. C.
    Hoppe, E. W.
    Humble, P. H.
    Keillor, M. E.
    LaFerriere, B. D.
    Mace, E. K.
    McIntyre, J. I.
    Merriman, J. H.
    Miley, H. S.
    Myers, A. W.
    Orrell, J. L.
    Overman, C. T.
    Panisko, M. E.
    Williams, R. M.
    LOW RADIOACTIVITY TECHNIQUES 2013 (LRT 2013), 2013, 1549 : 26 - 29
  • [4] Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting
    Mace, Emily
    Aalseth, Craig
    Alexander, Tom
    Back, Henning
    Day, Anthony
    Hoppe, Eric
    Keillor, Martin
    Moran, Jim
    Overman, Cory
    Panisko, Mark
    Seifert, Allen
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 171 - 174
  • [5] An ultra-low-background detector for axion searches
    Aune, S.
    Dafni, T.
    Fanourakis, G.
    Ribas, E. Ferrer
    Galan Lacarra, J.
    Geralis, T.
    Giomataris, I.
    Iguaz, F. J.
    Irastorza, I. G.
    Kousouris, K.
    Morales, J.
    Mols, J. P.
    Papaevangelou, T.
    Ruz, J.
    Tomas, A.
    Vafeiadis, T.
    FOURTH SYMPOSIUM ON LARGE TPCS FOR LOW ENERGY RARE EVENT DETECTION, 2009, 179
  • [6] First results of a simultaneous measurement of tritium and 14C in an ultra-low-background proportional counter for environmental sources of methane
    Mace, E. K.
    Aalseth, C. E.
    Day, A. R.
    Hoppe, E. W.
    Keillor, M. E.
    Moran, J. J.
    Panisko, M. E.
    Seifert, A.
    Tatishvili, G.
    Williams, R. M.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 155 : 122 - 129
  • [7] ULTRA-LOW-BACKGROUND APPARATUS WITH GERMANIUM SHIELDING
    POPEKO, LA
    LERBIN, AV
    CHERNYI, AV
    BAKHLANOV, SV
    MURATOVA, VN
    SHISHKINA, GA
    KLAPDOR, HV
    JETP LETTERS, 1989, 50 (05) : 247 - 250
  • [8] The design, construction, and initial characterization of an ultra-low-background gas-proportional counting system
    Seifert, A.
    Aalseth, C. E.
    Day, A. R.
    Fuller, E. S.
    Hoppe, E. W.
    Keillor, M. E.
    Mace, E. K.
    Overman, C. T.
    Warren, G. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) : 915 - 921
  • [9] The design, construction, and initial characterization of an ultra-low-background gas-proportional counting system
    A. Seifert
    C. E. Aalseth
    A. R. Day
    E. S. Fuller
    E. W. Hoppe
    M. E. Keillor
    E. K. Mace
    C. T. Overman
    G. A. Warren
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 915 - 921
  • [10] Ultra-low-background copper production and clean fabrication
    Aalseth, CE
    Brodzinski, RL
    Farmer, OT
    Hoppe, EW
    Hossbach, TW
    Miley, HS
    Reeves, JH
    Topical Workshop on Low Radioactivity Techniques, 2005, 785 : 170 - 176