Enhancing performance of a miniaturized surface plasmon resonance sensor in the reflectance detection mode using a waveguide-coupled bimetallic chip

被引:9
|
作者
Lee, Yeon Kyung [1 ]
Jang, Dae Ho [2 ]
Lee, Kyeong-Seok [3 ]
Kim, Won Mok [3 ]
Sohn, Young-Soo [1 ]
机构
[1] Catholic Univ Daegu, Dept Biomed Engn, Gyongsan 712702, Gyeongbuk, South Korea
[2] Sungkyunkwan Univ, Bio Lab, KDmedia Inc, Suwon 440746, South Korea
[3] Korea Inst Sci & Technol, Elect Mat Res Ctr, Seoul 136791, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Waveguide-coupled bimetallic chip; Miniaturized SPR sensor; Intensity measurement; Low molecular weight biomolecule; OPTICAL BIOSENSORS; HIGH-SENSITIVITY; FIXED-ANGLE; SPR SENSORS; FILM; ENHANCEMENT; RESOLUTION;
D O I
10.1186/1556-276X-8-344
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The characteristics of a waveguide-coupled bimetallic (WcBiM) chip in a miniaturized surface plasmon resonance (SPR) sensor and its detection capability for a low molecular weight biomolecule were investigated. The configuration of the WcBiM chip was gold (Au)/waveguide (ZnS-SiO2)/silver (Ag). In the intensity measurement mode, the sensitivity could be improved by reducing the full width at half maximum (FWHM) of the reflectance curve. The FWHM of the WcBiM chip is narrower than that of the Au chip, which suggests that the slope of the reflectance curve for the WcBiM chip is steeper. In order to generate enhanced resolution, the reflectance should be monitored at the specific angle where the slope is the steepest in the reflectance curve. For the detection of biotin that is a low molecular weight biomolecule, streptavidin was formed on the SPR sensor chip surface. The response of the SPR to biotin at various concentrations was then acquired. The sensitivities of the WcBiM chip and the Au chip were 0.0052%/(ng/ml) and 0.0021%/(ng/ml), respectively. The limit of detection of the biotin concentration for both the WcBiM and Au chips was calculated. The values were 2.87 ng/ml for the WcBiM chip and 16.63 ng/ml for the Au chip. Enhancement of the sensitivity in the intensity detection mode was achieved using the WcBiM chip compared with the Au chip. Therefore, sufficient sensitivity for the detection of a disease-related biomarker is attainable with the WcBiM chip in the intensity measurement mode using a miniaturized SPR sensor.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [41] Simultaneous Detection of Ammonia and Water Vapors Using Surface Plasmon Resonance Waveguide Sensor
    Komai, Ryo
    Honda, Hiroki
    Baba, Akira
    Shinbo, Kazunari
    Kato, Keizo
    Kaneko, Futao
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 284 - 286
  • [42] Lossy mode resonance surface plasmon resonance sensor for malaria detection
    Singh, Bhupinder
    Dixit, Amit
    Dua, Piyush
    JOURNAL OF OPTICS-INDIA, 2024, 53 (5): : 4466 - 4476
  • [43] Surface Plasmon Field-Enhanced Raman Scattering Based on Evanescent Field Excitation of Waveguide-Coupled Surface Plasmon Resonance Configuration
    Zhang, Haitao
    Geng, Yijia
    Xu, Shuping
    Xu, Weiqing
    Tian, Yu
    Yu, Jie
    Deng, Wenyuan
    Yu, Bo
    Liu, Yu
    JOURNAL OF PHYSICAL CHEMISTRY C, 2020, 124 (02): : 1640 - 1645
  • [44] Detection of porphyrin using a short peptide immobilized on a surface plasmon resonance sensor chip
    Nakamura, C
    Inuyama, Y
    Shirai, K
    Sugimoto, N
    Miyake, J
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12): : 1095 - 1100
  • [45] Analysis of bimolecular interactions using a miniaturized surface plasmon resonance sensor
    Whelan, RJ
    Wohland, T
    Neumann, L
    Huang, B
    Kobilka, BK
    Zare, RN
    ANALYTICAL CHEMISTRY, 2002, 74 (17) : 4570 - 4576
  • [46] A miniaturized germanium-doped silicon dioxide-based surface plasmon resonance waveguide sensor for immunoassay detection
    Huang, Jhen-Gang
    Lee, Chen-Lung
    Lin, Hsueh-Min
    Chuang, Tsung-Liang
    Wang, Way-Seen
    Juang, Rong-Huey
    Wang, Ching-Ho
    Lee, Chih Kung
    Lin, Shi-Ming
    Lin, Chii-Wann
    BIOSENSORS & BIOELECTRONICS, 2006, 22 (04): : 519 - 525
  • [47] Parametric study on the bimetallic waveguide coupled surface plasmon resonance sensors in comparison with other configurations
    Lee, Kyeong-Seok
    Lee, Taek Sung
    Kim, Inho
    Kim, Won Mok
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (12)
  • [48] Fabrication and metrology of an electro-optic polymer light modulator based on waveguide-coupled surface plasmon resonance
    Chyou, JJ
    Chu, CS
    Shih, ZH
    Lin, CY
    Chen, SJ
    Shu, FC
    OPTICAL ENGINEERING, 2005, 44 (03) : 1 - 7
  • [49] Silicon carbide based surface plasmon resonance waveguide sensor with a bimetallic layer for improved sensitivity
    Du, Wei
    Zhao, Feng
    MATERIALS LETTERS, 2017, 186 : 224 - 226
  • [50] High efficiency electro-optic polymer light modulator based on waveguide-coupled surface plasmon resonance
    Chyou, JJ
    Chu, CS
    Shih, ZH
    Lin, CY
    Huang, KT
    Chen, SJ
    Shu, SF
    PLASMONICS: METALLIC NANOSTRUCTURES AND THEIR OPTICAL PROPERTIES, 2003, 5221 : 197 - 206