Usability of Absorber-lined Shielded Environment for Low-frequency Magnetic Field Measurement

被引:0
|
作者
Kawai, Kazuma [1 ]
Nagakusa, Seiji [1 ]
Murasato, Kazutaka [1 ]
Naoi, Takashi [1 ]
Iida, Michihira [1 ]
Nakamura, Katsumi [1 ]
机构
[1] DENSO Corp, Engn R&D Ctr, 1-1 Showa Cho, Kariya, Aichi, Japan
关键词
automobile; magnetic field; measuremente; absorber-lined shielded environment; shielded room; outdoor test site; radio wave absorber;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses the results of a study the authors conducted to clarify the usability of an absorber-lined shielded environment (ALSE) as a 150 kHz and lower frequency magnetic field measurement environment using the mirror image method. The magnetic field strength at a measurement point obtained from the mirror image method almost agreed with the measured value and the value obtained by a 3D electromagnetic field analysis, confirming that the mirror image method is effective for estimating the magnetic field strength at a specific measurement point. It was also confirmed that the usability of ALSE for magnetic field measurement depends largely on the distance of the magnetic field source and measurement point from the six walls of the ALSE. The study confirmed that, if the distance between the magnetic field source and measurement point is 1 m or less and they are 1 m or more from the ALSE's wall surfaces, the value measured in an ALSE that can be used to measure electromagnetic emissions from components does not differ by more than 3 dB from the value measured at an outdoor test site (OTS) for automobile evaluation.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Magnetic properties of ferromagnetic cores in a low-frequency uniform field
    Sandovskii, VA
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2005, 41 (10) : 666 - 673
  • [42] LOW-FREQUENCY FIBER OPTIC MAGNETIC-FIELD SENSORS
    NADERREZVANI, N
    CLAUS, RO
    SARRAFZADEH, AK
    OPTICAL ENGINEERING, 1992, 31 (01) : 23 - 27
  • [43] MAGNETIC FIELD INFLUENCE ON LOW-FREQUENCY OSCILLATIONS OF GUNN DIODES
    GOLDBERG, YA
    LEVINSHTEIN, ME
    NASLEDOV, DN
    PHYSICA STATUS SOLIDI, 1968, 29 (02): : K103 - +
  • [44] ACTION OF A LOW-FREQUENCY MAGNETIC-FIELD ON THE MYOCARDIUM CONTRACTILITY
    PIRUZIAN, LA
    KSHUTASHVILI, TS
    NAKIPOVA, OV
    LAZAREV, AV
    KUZNETSOV, AN
    DOKLADY AKADEMII NAUK SSSR, 1983, 270 (06): : 1486 - 1488
  • [45] Suppression of low-frequency interferences in the induction sensor of magnetic field
    Sklyar, Rostyslav
    MEASUREMENT, 2006, 39 (07) : 634 - 642
  • [46] Analysis and test of EM shielding for low-frequency magnetic field
    Zhu Yichao
    Gao Cheng
    Shi Lihua
    Zhou Bihua
    2007 4TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY PROCEEDING: EMC 2007, 2007, : 345 - 349
  • [47] MEASUREMENT OF LOW-FREQUENCY ABSORPTION
    DAVERN, WA
    APPLIED ACOUSTICS, 1987, 21 (01) : 1 - 11
  • [48] Quantification of Low Frequency Magnetic Field in Living Environment
    Mizuno, Yukio
    Tanaka, Kenji
    Naito, Katsuhiko
    10TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2011, : 811 - 815
  • [49] Frequency resonance effect of neurons under low-frequency weak magnetic field
    Azanza, Maria J.
    del Moral, A.
    Bruzon, R. N. Perez
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 310 (02) : 2865 - 2867
  • [50] Harmonic and radio frequency generation in superconducting films by low-frequency magnetic field
    Tinchev, SS
    Lykov, A
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (03): : L10 - L12