Usability of Absorber-lined Shielded Environment for Low-frequency Magnetic Field Measurement

被引:0
|
作者
Kawai, Kazuma [1 ]
Nagakusa, Seiji [1 ]
Murasato, Kazutaka [1 ]
Naoi, Takashi [1 ]
Iida, Michihira [1 ]
Nakamura, Katsumi [1 ]
机构
[1] DENSO Corp, Engn R&D Ctr, 1-1 Showa Cho, Kariya, Aichi, Japan
关键词
automobile; magnetic field; measuremente; absorber-lined shielded environment; shielded room; outdoor test site; radio wave absorber;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses the results of a study the authors conducted to clarify the usability of an absorber-lined shielded environment (ALSE) as a 150 kHz and lower frequency magnetic field measurement environment using the mirror image method. The magnetic field strength at a measurement point obtained from the mirror image method almost agreed with the measured value and the value obtained by a 3D electromagnetic field analysis, confirming that the mirror image method is effective for estimating the magnetic field strength at a specific measurement point. It was also confirmed that the usability of ALSE for magnetic field measurement depends largely on the distance of the magnetic field source and measurement point from the six walls of the ALSE. The study confirmed that, if the distance between the magnetic field source and measurement point is 1 m or less and they are 1 m or more from the ALSE's wall surfaces, the value measured in an ALSE that can be used to measure electromagnetic emissions from components does not differ by more than 3 dB from the value measured at an outdoor test site (OTS) for automobile evaluation.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] VIBRATIONAL NOISE CANCELING TECHNIQUE FOR LOW-FREQUENCY, LOW-LEVEL MAGNETIC-FIELD MEASUREMENT
    SASADA, I
    YAMAUCHI, T
    IEEE TRANSACTIONS ON MAGNETICS, 1995, 31 (06) : 3406 - 3408
  • [12] Cell-cycle kinetics of friend erythroleukemia cells in a magnetically shielded room and in a low-frequency/low-intensity magnetic field
    Eremenko, T
    Esposito, C
    Pasquarelli, A
    Pasquali, E
    Volpe, P
    BIOELECTROMAGNETICS, 1997, 18 (01) : 58 - 66
  • [13] Low-frequency magnetic field in DC railway substations
    Mariscotti, A
    Pozzobon, P
    IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2004, 53 (01) : 192 - 198
  • [14] Low-frequency magnetic field detection for metal sensing
    Kiwa, Toshihiko
    Kawata, Tomoaki
    Tsukada, Keiji
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2007, 25 (1-4) : 447 - 451
  • [15] PROPAGATION OF LOW-FREQUENCY ELECTROSTATIC WAVES IN A MAGNETIC FIELD
    JOYCE, G
    DORY, RA
    PHYSICS OF FLUIDS, 1970, 13 (04) : 1017 - &
  • [16] PENETRATION OF LOW-FREQUENCY MAGNETIC-FIELD IN CADMIUM
    MACINNES, WM
    PROBST, PA
    COLLET, B
    HUGUENIN, R
    HELVETICA PHYSICA ACTA, 1975, 48 (04): : 435 - 435
  • [17] LOW-FREQUENCY ELECTROSTATIC WAVES IN A MAGNETIC FIELD WITH COLLISIONS
    OHNUMA, T
    HATTA, Y
    TSUZI, N
    KIZIMA, Y
    PHYSICS LETTERS A, 1970, A 32 (07) : 500 - &
  • [18] Low-frequency magnetic field effect on cytoskeleton and chromatin
    Kroupova, Jana
    Bartova, Eva
    Fojt, Lukas
    Strasak, Ludek
    Kozubek, Stanislav
    Vetterl, Vladimir
    BIOELECTROCHEMISTRY, 2007, 70 (01) : 96 - 100
  • [19] METHOD OF TESTING AND QUALIFYING SHIELDED LOW-FREQUENCY CABLES
    OSVATH, P
    KEZDI, G
    ZOLTAN, I
    PERIODICA POLYTECHNICA-ELECTRICAL ENGINEERING, 1976, 20 (04): : 417 - 432
  • [20] MODEL OF LOW-FREQUENCY SOUND PROPAGATION IN A LINED DUCT
    STAROBINSKII, RN
    YUDIN, EY
    SOVIET PHYSICS ACOUSTICS-USSR, 1972, 18 (01): : 91 - +