Clinical and Histopathologic Review of 18 Explanted Porous Polyethylene Orbital Implants

被引:34
|
作者
Chuo, Jean Y. [2 ,3 ]
Dolman, Peter J. [1 ,2 ,3 ]
Ng, Tony L. [3 ,4 ]
Buffam, Frank V. [2 ,3 ]
White, Valerie A. [2 ,3 ,4 ]
机构
[1] Vancouver Gen Hosp, Dept Ophthalmol, Eye Care Ctr, Sect 1, Vancouver, BC V5Z 3N9, Canada
[2] Vancouver Gen Hosp, Dept Visual Sci, Vancouver, BC V5Z 3N9, Canada
[3] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[4] Vancouver Gen Hosp, Dept Pathol, Vancouver, BC V5Z 3N9, Canada
关键词
CORALLINE HYDROXYAPATITE; ANOPHTHALMIC SOCKET; EXPOSURE; INFECTION; EVISCERATION; ENUCLEATION; COMPLICATIONS; SURGERY; SPHERES; MEDPOR;
D O I
10.1016/j.ophtha.2008.09.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To review the clinical and histopathologic features of porous polyethylene (PP) orbital implants requiring explantation. Design: Case series. Participants: Eighteen explanted PP orbital implants of 18 patients were studied. Methods: The charts and histopathologic findings were reviewed for all patients requiring explantation of PP orbital implants between 1997 and 2006 by 2 oculoplastic surgeons at the University of British Columbia. Main Outcome Measures: Clinical data obtained included patient demographics, the nature of the primary surgery, and the clinical presentation leading to eventual implant removal. The histopathologic data observed included the presence of anterior exposure, area of fibrovascular ingrowth, type of inflammation, and presence and type of bacterial colonies. Results: Nine (50%) of the 18 patients studied were referred from other surgeons. The balance represented 3.2% of all PP implants placed by the 2 surgeons. The procedures for the primary surgery were 12 enucleations (67%), 5 eviscerations (28%), and 1 secondary implant (5%). Clinical findings included anterior implant exposure and discharge in all cases. Histopathologic analysis was performed in all of the implants and showed less than 50% fibrovascular ingrowth in 16 implants (89%) and predominantly acute or mixed inflammation in 15 (83%). Foreign body giant cells were seen adjacent to the implant material in all cases. Bacterial colonies on gram stain were identified in 12 specimens (67%); overall, gram-positive cocci in clusters or chains were found in 10 implants (56%), and gram-negative bacteria were found in 1 (5.5%). Thirteen patients (72%) lived in locations distant from Vancouver, the surgical center. Conclusions: This article presents the largest review of explanted porous polyethylene orbital spheres. The findings suggest that anterior exposure allows bacterial colonization and the development of a heavy inflammatory infiltrate. Poor tissue ingrowth may limit the penetration of topical or systemic antibiotic therapy, leading to the necessity for explantation. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2009;116:349-354 (C) 2009 by the American Academy of Ophthalmology.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 50 条
  • [21] Porous orbital implants in enucleation: A systematic review
    Chalasani, Rajeev
    Poole-Warren, Laura
    Conway, R. Max
    Ben-Nissan, Besini
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (02) : 145 - 155
  • [22] Primary placement of a motility coupling post in porous polyethylene orbital implants
    Rubin, PAD
    Fay, AM
    Remulla, HD
    ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (06) : 826 - 832
  • [23] Reconstruction of Orbital Floor Fractures with Porous Polyethylene Implants: A Prospective Study
    Sai Krishna D.
    Soumadip D.
    Journal of Maxillofacial and Oral Surgery, 2016, 15 (3) : 300 - 307
  • [24] Orbital floor repair using medpor porous polyethylene implants.
    Lupi, E
    Messi, M
    Ascani, G
    Balercia, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U504 - U504
  • [25] Re: 'Long-term surgical outcomes of porous polyethylene orbital implants: a review of 314 cases'
    Kamal, Saurabh
    Bodh, Sonam Angmo
    Goel, Ruchi
    Kumar, Sushil
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (08) : 1153 - 1153
  • [26] Porous orbital implants
    Cleres, B.
    Meyer-Ruesenberg, H. W.
    OPHTHALMOLOGE, 2014, 111 (06): : 572 - 576
  • [27] Orbital reconstruction using custom-made orbital alloplastic porous polyethylene implants.
    Goodman, RL
    Holck, DE
    Ng, JD
    Kikkawa, DO
    Piest, KL
    Otto, R
    Soparkar, CN
    Patrinely, JR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S342 - S342
  • [28] Comparison of Surgical Outcomes of Large Orbital Fractures Reconstructed With Porous Polyethylene Channel and Porous Polyethylene Titan Barrier Implants
    Kim, Chang Yeom
    Jeong, Byung Jin
    Lee, Sang Yeul
    Yoon, Jin Sook
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 28 (03): : 176 - 180
  • [29] Porous Polyethylene Implants in Orbital Blow-Out Fractures and Enophthalmos Reconstruction
    Xu, Jia-jie
    Teng, Li
    Jin, Xiao-lei
    Ji, Ying
    Lu, Jian-jian
    Zhang, Bo
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (03) : 918 - 920
  • [30] Effects and complications of placement of motility coupling post in porous polyethylene orbital implants
    Hong-guang Cui
    Rong-rong Hu
    Hui-yan Li
    Wei Han
    Journal of Zhejiang University SCIENCE B, 2008, 9 : 464 - 469