Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry

被引:275
|
作者
Kohlhaas, M
Boehm, AG
Spoerl, E
Pürsten, A
Grein, HJ
Pillunat, LE
机构
[1] Univ Carl Gustav Carus, Dept Ophthalmol, Dresden, Germany
[2] Univ Appl Sci, Dept Optometry, Jena, Germany
关键词
D O I
10.1001/archopht.124.4.471
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the effect of central corneal thickness (CCT), corneal curvature, and axial length on applanation tonometry in an in vivo study. Methods: In a masked, prospective clinical trial, we examined 125 eyes of 125 patients scheduled for cataract surgery. Corneal curvature was measured by means of keratometry and axial length by A-scan ultrasonography. By cannulating the anterior chamber before surgery, intraocular pressure (IOP) was set to 20, 35, and 50 mm Hg in a closed system by means of a water column. After measuring thickness, the IOP was measured with an applanation tonometer. Pearson product moment correlations and multiple linear regression analyses were performed, and significance levels were evaluated by the paired, 2-tailed t test. Results: The difference between measured and real IOP was significantly dependent (P < 001) on CCT. The associations between IOP and corneal curvature or IOP and axial length were not statistically significant (P=. 31). The association between IOP reading and CCT is shown in the "Dresdner correction table," which illustrates an approximately 1-mm Hg correction for every 25-mu m deviation from a CCT of 550 mu m. The correction values were positive as thickness decreased and negative as thickness increased. Conclusions: Central corneal thickness significantly affects IOP readings obtained by applanation tonometry according to the Goldmann principle. A correction of IOP readings by considering CCT according to the Dresdner correction table ight be helpful for determining an accurate IOP value.
引用
收藏
页码:471 / 476
页数:6
相关论文
共 50 条
  • [21] Central corneal thickness changes after Goldmann applanation tonometry and gonioscopy
    Evangelista, JA
    Oakman, JH
    Johnson, DL
    Tao, JP
    Trespalacios, R
    Hitch, AD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [22] Correlation Between Goldmann Applanation Tonometry and Rebound Tonometry in Relation to Central Corneal Thickness
    Brandtner, H.
    Hitzl, W.
    Strohmaier, C.
    Abri, S.
    Wintersteller, C.
    Hohensinn, M.
    Ruckhofer, J.
    Stoiber, J.
    Grabner, G.
    Reitsamer, H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [23] THE EFFECT OF CORNEAL HYDRATION ON APPLANATION TONOMETRY AND CORNEAL TOPOGRAPHY
    SMALL, RH
    SIMON, G
    BEN, QS
    PAREL, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 733 - 733
  • [24] Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonomet
    Francis, Brian A.
    Hsieh, Amy
    Lai, Mei-Ying
    Chopra, Vikas
    Pena, Fernando
    Azen, Stanley
    Varma, Rohit
    OPHTHALMOLOGY, 2007, 114 (01) : 20 - 26
  • [25] Comparison of central corneal thickness, corneal curvature and axial length values in pseudoexfoliation cases with or without cataract
    Okumus, Seydi
    Tatar, M. Gurkan
    Gungor, Kivanc
    Bekir, Necdet
    EUROPEAN JOURNAL OF THERAPEUTICS, 2011, 17 (03): : 137 - 140
  • [26] Effects of corneal thickness, curvature, astigmatism and direction of gaze on Goldmann applanation tonometry readings
    Rask, G
    Behndig, A
    OPHTHALMIC RESEARCH, 2006, 38 (01) : 49 - 55
  • [27] Effect of central corneal thickness on Goldmann applanation tonometry measures - a different result with different pachymeters
    Doughty, Michael J.
    Jonuscheit, Sven
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (11) : 1603 - 1610
  • [28] Effect of central corneal thickness on Goldmann applanation tonometry measures—a different result with different pachymeters
    Michael J. Doughty
    Sven Jonuscheit
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1603 - 1610
  • [29] Effect of central corneal thickness on dynamic contour tonometry and goldmann applanation tonometry in primary open-angle glaucoma
    Grieshaber, Matthias C.
    Schoetzau, Andreas
    Zawinka, Claudia
    Flammer, Josef
    Orgul, Selim
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (06) : 740 - 744
  • [30] Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length
    Chen, Mei-Ju
    Liu, Yin-Tzu
    Tsai, Chia-Chen
    Chen, Yen-Cheng
    Chou, Ching-Kuang
    Lee, Shu-Mei
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (03) : 133 - 137