Behavior of MV Lines from 2.5 to 100 kHz

被引:0
|
作者
Langella, R. [1 ]
Nugnes, L. [1 ]
Testa, A. [1 ]
机构
[1] Univ Naples 2, Dipartimento Ingn Informaz, I-81031 Aversa, CE, Italy
关键词
Distribution Generation; Harmonic and Interharmonic Distortion; Equivalent circuits;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The large penetration of distributed generation requires accurate over-head line and cable models in a frequency range much wider than the classical interval, 0-2.5 kHz, used for traditional harmonic and interharmonic penetration studies. In this paper, the results obtained in previous papers by the same authors on the behavior of both over-head and cable MV lines in the frequency range from 0 to 100 kHz are reported. Reference is made to models based on the classical. line equivalent circuits of different complexities. The results of the different models are illustrated in terms of output terminal impedance magnitude; a very simple case study is also presented.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A new method to extend the current ranges from 10 mA to 100 A at frequencies up to 100 kHz
    Pan, Xianlin
    Zhang, Jiangtao
    Song, Ying
    Shi, Zhaomin
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [32] Effect of Body Positions and Movements in a Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz
    Lucev, Zeljka
    Krois, Igor
    Cifrek, Mario
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 2791 - 2795
  • [33] 100-mV polarization criterion
    Dearing, B.M.
    Materials Performance, 1994, 33 (09): : 23 - 27
  • [34] Characteristics of 2.5 MV beam and imaging dose to patients
    Ding, George X.
    Munro, Peter
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 541 - 547
  • [35] Image Quality Comparison and Dose Quantification for 2.5 MV
    Stowe, M.
    DiCostanzo, D.
    Ayan, A.
    Woollard, J.
    Gupta, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3265 - 3265
  • [36] Dosimetrical Characteristics of a 2.5 MV Megavoltage Photon Beam
    Anamalayil, S.
    Liu, H.
    Kim, M.
    Zhu, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3408 - 3408
  • [37] ANODE SPUTTERING CHARACTERISTICS OF BERKELEY 2.5 MV SOURCE
    GAVIN, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (02) : 1008 - 1012
  • [38] Characterization of a 2.5 MV inline portal imaging beam
    Grafe, James L.
    Owen, Jennifer
    Villarreal-Barajas, J. Eduardo
    Khan, Rao F. H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 222 - 234
  • [40] AMBIENT NOISE MEASUREMENTS FROM 100 HZ TO 80 KHZ IN AN ALASKAN FJORD
    MCCONNELL, SO
    SCHILT, MP
    DWORSKI, JG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (04): : 1990 - 2003