Behavior of MV Lines from 2.5 to 100 kHz

被引:0
|
作者
Langella, R. [1 ]
Nugnes, L. [1 ]
Testa, A. [1 ]
机构
[1] Univ Naples 2, Dipartimento Ingn Informaz, I-81031 Aversa, CE, Italy
关键词
Distribution Generation; Harmonic and Interharmonic Distortion; Equivalent circuits;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The large penetration of distributed generation requires accurate over-head line and cable models in a frequency range much wider than the classical interval, 0-2.5 kHz, used for traditional harmonic and interharmonic penetration studies. In this paper, the results obtained in previous papers by the same authors on the behavior of both over-head and cable MV lines in the frequency range from 0 to 100 kHz are reported. Reference is made to models based on the classical. line equivalent circuits of different complexities. The results of the different models are illustrated in terms of output terminal impedance magnitude; a very simple case study is also presented.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] A Kelvin resistance bridge with the frequency range from dc to 100 khz
    Huang, L.
    Li, Z.
    Zhang, Z.
    Zhao, W.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 554 - +
  • [22] ACTIVE ANTENNAS IN FREQUENCY RANGE FROM 100 KHZ TO 250 MHZ
    FLACHENECKER, G
    LANDSTORFER, F
    LINDENMEIER, H
    NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1971, 24 (05): : 231 - +
  • [23] Setup for Generating an AC Magnetic Field From 3 to 100 kHz
    Ulvr, Michal
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (01)
  • [24] 100 kHz MEMS Vibratory Gyroscope
    Liewald, Jan-Timo
    Kuhlmann, Burkhard
    Balslink, Thorsten
    Traechtler, Martin
    Dienger, Matthias
    Manoli, Yiannos
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2013, 22 (05) : 1115 - 1125
  • [25] Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
    Dobrzynski, Krzysztof
    Lubosny, Zbigniew
    Klucznik, Jacek
    Grala, Janusz
    Falkowski, Dominik
    ENERGIES, 2020, 13 (20)
  • [26] ELECTRICAL RESISTIVITY OF LUNG AT 100 KHZ
    WITSOE, DA
    KINNEN, E
    MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03): : 239 - +
  • [27] Comparison of Patient-Specific Dose From 2.5 MV and 6 MV Imaging Beams Calculated Using a Commercial TPS
    Ferris, W.
    Culberson, W.
    Labby, Z.
    MEDICAL PHYSICS, 2019, 46 (06) : E355 - E356
  • [28] ARRAYS FOR AIRBORNE 100 KHZ ULTRASOUND
    MUNRO, WSH
    WYKES, C
    ULTRASONICS, 1994, 32 (01) : 57 - 64
  • [29] Is There a Dosimetric Advantage of Using 2.5 MV Over 6 MV Photons for Stereotactic Radiosurgery?
    Ding, G.
    Luo, G.
    Price, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E468 - E468
  • [30] A 2.5 kHz magnetostrictive Tonpilz sonar transducer design
    Butler, SC
    SMART STRUCTURES AND MATERIALS 2002: ACTIVE MATERIALS: BEHAVIOR AND MECHANICS, 2002, 4699 : 510 - 521