Flow-injection chemiluminescence and electrogenerated chemiluminescence determination of escitalopram oxalate in tablet form

被引:9
|
作者
Alarfaj, Nawal A. [1 ]
Aly, Fatma A. [1 ]
Al-Qahtany, Abeer A. [1 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11495, Saudi Arabia
关键词
flow-injection chemiluminescence; flow-injection electrogenerated chemiluminescence; escitalopram oxalate; cerium(IV); tris(2; 2'-bipyridyl) ruthenium(II); tablets; CHROMATOGRAPHY; CITALOPRAM; CLONAZEPAM; METABOLITES; PLASMA;
D O I
10.1002/bio.2372
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid, simple and highly sensitive flow-injection (FI) chemiluminescence (CL) and flow-injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'-bipyridyl)ruthenium(II) (Ru(bipy)32+). Various experimental parameters affecting CL intensity were carefully studied and optimised. The method enabled the determination of 0.001-50 mu g/mL of ESC in bulk form with a correlation coefficient r=0.9999. The limit of detection (LOD) was 0.01ng/mL (S/N=3). The ECL method was based on the ECL reaction of Ru(bipy)32+ with the drug in an acidic medium, permitting the determination of ESC in the range of 0.00001-70 mu g/mL with r=0.9999 and LOD of 1 x 10-4ng/mL. The proposed methods were applied to the determination of ESC in commercial tablets. The results were compared statistically with those obtained from a published method using t- and F-tests. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:84 / 92
页数:9
相关论文
共 50 条
  • [31] A Flow-Injection Chemiluminescence Determination of Formaldehyde in Textiles
    Kanwal, Shamsa
    Ma, Qiang
    Fu, Xiaohong
    Yuan, Pingfan
    Su, Xingguang
    SPECTROSCOPY LETTERS, 2010, 43 (02) : 84 - 90
  • [32] Determination of diethylstilboestrol by flow-injection chemiluminescence immunoassay
    Wang, S.
    Li, L.
    Liang, Y.
    Zhao, Y.
    LUMINESCENCE, 2008, 23 (02) : 100 - 100
  • [33] Flow-injection chemiluminescence determination of quinine using on-line electrogenerated cobalt(III) as oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    TALANTA, 2000, 51 (03) : 515 - 521
  • [34] The investigation of a new flow-injection analysis electrogenerated chemiluminescence method and the determination of S2-
    Zheng, XW
    Zhang, ZJ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1999, 20 (02): : 209 - 213
  • [35] Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO- as oxidant
    Zheng, XW
    Zhang, ZJ
    ANALYST, 1999, 124 (05) : 763 - 766
  • [36] Flow-injection chemiluminescence determination of hydrazine using on-line electrogenerated BrO- as the oxidant
    Li, BX
    Zhang, ZJ
    Zheng, XW
    Xu, CL
    CHEMIA ANALITYCZNA, 2000, 45 (05): : 709 - 717
  • [37] Flow-injection chemiluminescence determination of captopril using on-line electrogenerated silver(II) as the oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    MICROCHEMICAL JOURNAL, 2001, 70 (02) : 85 - 91
  • [38] Flow-injection chemiluminescence determination of sulfite using on-line electrogenerated silver(II) as the oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    ANALYTICA CHIMICA ACTA, 2001, 432 (02) : 311 - 316
  • [39] Flow injection chemiluminescence determination of adreson with electrogenerated manganese QID
    Chen, XN
    Zhang, CX
    Lü, JR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (09) : 1126 - 1128
  • [40] Chemiluminescence flow-injection immunoassays
    Gübitz, G
    Schmid, MG
    Silviaeh, H
    Aboul-Enein, HY
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (03) : 167 - 174