A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope

被引:6
|
作者
Choi, Hyun Young [1 ]
Oh, Young Min [2 ]
Kang, Gu Hyun [1 ]
Kang, Hyunggoo [3 ]
Jang, Yong Soo [1 ]
Kim, Wonhee [1 ]
Kim, Euichung [4 ]
Cho, Young Soon [5 ]
Choi, Hyukjoong [3 ]
Kim, Hyunjong [6 ]
Kim, Gyoung Yong [7 ]
机构
[1] Hallym Univ, Kangnam Sacred Heart Hosp, Coll Med, Dept Emergency Med, Seoul 150950, South Korea
[2] Catholic Univ Korea, Uijeongbu St Marys Hosp, Coll Med, Dept Emergency Med, Uijongbu 480717, South Korea
[3] Hanyang Univ, Coll Med, Dept Emergency Med, Seoul 133791, South Korea
[4] CHA Univ, Sch Med, Dept Emergency Med, Songnam 463712, Gyeonggi Do, South Korea
[5] Soonchunhyang Univ, Bucheon Hosp, Dept Emergency Med, Bucheon 420767, South Korea
[6] Inje Univ, Ilsan Paik Hosp, Dept Emergency Med, Ilsan 411706, South Korea
[7] Gyeonggi Fire Serv Acad, Yongin 449882, South Korea
关键词
TRACHEAL INTUBATION; MANAGEMENT;
D O I
10.1155/2015/961782
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of the Success of Two Techniques for the Endotracheal Intubation with C-MAC Video Laryngoscope Miller Blade in Children: A Prospective Randomized Study
    Sinha, Renu
    Sharma, Ankur
    Ray, Bikash Ranjan
    Pandey, Ravinder Kumar
    Darlong, Vanlalnghka
    Punj, Jyotsna
    Chandralekha, Chandralekha
    Upadhyay, Ashish Datt
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2016, 2016
  • [42] Comparison of Macintosh, McCoy, and Glidescope video laryngoscope for intubation in morbidly obese patients: Randomized controlled trial
    Nandakumar, Keerthi P.
    Bhalla, Amar P.
    Pandey, Ravindra Kumar
    Baidya, Dalim Kumar
    Subramaniam, Rajeshwari
    Kashyap, Lokesh
    SAUDI JOURNAL OF ANAESTHESIA, 2018, 12 (03) : 433 - 439
  • [43] Endotracheal tube introducer-assisted intubation with the GlideScope video laryngoscope
    Conklin, Lori D.
    Cox, William S.
    Blank, Randal S.
    JOURNAL OF CLINICAL ANESTHESIA, 2010, 22 (04) : 303 - 305
  • [44] Randomized comparison of the airway scope and the macintosh laryngoscope for the tracheal intubation in manikin study
    Yuasa, Haruyuki
    Yokoyama, Hiroyuki
    Yonemoto, Naohiro
    Kada, Akiko
    Kasahara, Yoichiro
    Koga, Yoshihisa
    Nonogi, Hiroshi
    CIRCULATION, 2007, 116 (16) : 944 - 944
  • [45] Influence of clinical experience of the Macintosh laryngoscope on performance with the Pentax-AWS Airway Scope®, a rigid video-laryngoscope, by paramedics in Japan
    Kohei Ota
    Takuma Sadamori
    Shinji Kusunoki
    Tadatsugu Otani
    Tomoko Tamura
    Kazunobu Une
    Yoshiko Kida
    Junji Itai
    Yasumasa Iwasaki
    Nobuyuki Hirohashi
    Masakazu Nakao
    Koichi Tanigawa
    Journal of Anesthesia, 2015, 29 : 672 - 677
  • [46] Comparison of LMA CTrach and Video Laryngoscope in Endotracheal Intubation
    Gumus, Nevzat
    Dilek, Ahmet
    Ulger, Fatma
    Koksal, Ersin
    Cetinoglu, Erhan Cetin
    Ozkan, Fatih
    Guldogus, Fuat
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2014, 42 (05) : 251 - 256
  • [47] Comparison of King Vision video laryngoscope (channeled blade) with Macintosh laryngoscope for tracheal intubation using armored endotracheal tubes
    Reena
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (03) : 359 - 362
  • [48] A Comparison of the Effectiveness of the McCoy Laryngoscope and the C-MAC D-Blade Video Laryngoscope in Obese Patients
    Lee, Jung-Min
    Lee, Soo-Kyung
    Jang, Minsoo
    Oh, Minho
    Park, Eun-Young
    MEDICINA-LITHUANIA, 2024, 60 (08):
  • [49] C-MAC Video Laryngoscope versus Conventional Direct Laryngoscopy for Endotracheal Intubation During Cardiopulmonary Resuscitation
    Min, Byeong Chul
    Park, Jong Eun
    Lee, Gun Tak
    Kim, Tae Rim
    Yoon, Hee
    Cha, Won Chul
    Shin, Tae Gun
    Song, Keun Jeong
    Park, Minsu
    Han, Heewon
    Hwang, Sung Yeon
    MEDICINA-LITHUANIA, 2019, 55 (06):
  • [50] Learning curve and performance in simulated difficult airway for the novel C-MAC® video-stylet and C-MAC® Macintosh video laryngoscope: A prospective randomized manikin trial
    Pius, James
    Noppens, Ruediger R.
    PLOS ONE, 2020, 15 (11):