A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope

被引:6
|
作者
Choi, Hyun Young [1 ]
Oh, Young Min [2 ]
Kang, Gu Hyun [1 ]
Kang, Hyunggoo [3 ]
Jang, Yong Soo [1 ]
Kim, Wonhee [1 ]
Kim, Euichung [4 ]
Cho, Young Soon [5 ]
Choi, Hyukjoong [3 ]
Kim, Hyunjong [6 ]
Kim, Gyoung Yong [7 ]
机构
[1] Hallym Univ, Kangnam Sacred Heart Hosp, Coll Med, Dept Emergency Med, Seoul 150950, South Korea
[2] Catholic Univ Korea, Uijeongbu St Marys Hosp, Coll Med, Dept Emergency Med, Uijongbu 480717, South Korea
[3] Hanyang Univ, Coll Med, Dept Emergency Med, Seoul 133791, South Korea
[4] CHA Univ, Sch Med, Dept Emergency Med, Songnam 463712, Gyeonggi Do, South Korea
[5] Soonchunhyang Univ, Bucheon Hosp, Dept Emergency Med, Bucheon 420767, South Korea
[6] Inje Univ, Ilsan Paik Hosp, Dept Emergency Med, Ilsan 411706, South Korea
[7] Gyeonggi Fire Serv Acad, Yongin 449882, South Korea
关键词
TRACHEAL INTUBATION; MANAGEMENT;
D O I
10.1155/2015/961782
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparing Postoperative Sore Throat (POST) Following Intubation using Macintosh Laryngoscope Versus C-MAC® Video Laryngoscope
    Khoo, B. H.
    Yeoh, C. N.
    Lee, C. Y.
    Nadia, M. N.
    Raha, A. R.
    MEDICINE AND HEALTH, 2022, 17 (02): : 36 - 44
  • [22] Comparison of the C-MAC video laryngoscope with direct Macintosh laryngoscopy in the emergency department
    Vassiliadis, John
    Tzannes, Alex
    Hitos, Kerry
    Brimble, Jessica
    Fogg, Toby
    EMERGENCY MEDICINE AUSTRALASIA, 2015, 27 (02) : 119 - 125
  • [23] Comparison of the C-MAC video laryngoscope to a flexible fiberoptic scope for intubation with cervical spine immobilization
    Yumul, Roya
    Elvir-Lazo, Ofelia L.
    White, Paul F.
    Durra, Omar
    Ternian, Alen
    Tamman, Richard
    Naruse, Robert
    Ebba, Hailu
    Yusufali, Taizoon
    Wong, Robert
    Conte, Antonio Hernandez
    Farnad, Shahbaz
    Pham, Christine
    Wender, Ronald H.
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 31 : 46 - 52
  • [24] The Accuracy of Tests Used to Predict Difficult Airway and a Comparison of Macintosh Laryngoscope to Video Laryngoscope for Intubation
    Mingir, Tarkan
    Kitapcioglu, Dilek
    Turgut, Namigar
    Yumru, Cengiz
    KUWAIT MEDICAL JOURNAL, 2015, 47 (03): : 201 - 209
  • [25] Comparison Between McCoy Laryngoscope and C-MAC Video Laryngoscope in Anticipated Difficult Airway: A Prospective Randomised Study
    Garg, Mukul
    Shakya, Raju
    Lyngdoh, Nari Mary
    Pradhan, Debasis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (07)
  • [26] Endotracheal Intubation Using C-MAC Video Laryngoscope vs. Direct Laryngoscope While Wearing Personal Protective Equipment
    Kim, Da Saem
    Jeong, Daun
    Park, Jong Eun
    Lee, Gun Tak
    Shin, Tae Gun
    Chang, Hansol
    Kim, Taerim
    Lee, Se Uk
    Yoon, Hee
    Cha, Won Chul
    Sim, Yong Jin
    Park, Song Yi
    Hwang, Sung Yeon
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (10):
  • [27] Comparison of the C-MAC D-blade video laryngoscope and the McCoy laryngoscope for double-lumen endotracheal tube intubation A prospective randomized controlled study
    Kim, Kyung Mi
    Seo, Kwon Hui
    Kim, You Jung
    John, Hyunji
    Moon, Hyun Soo
    Kim, Namhyun
    Yeon, Nayoung
    MEDICINE, 2022, 101 (45) : E31775
  • [28] Glidescope® video laryngoscope vs. Macintosh direct laryngoscope for the intubation of laryngeal neoplasm patients: a randomized controlled study
    Hu, Bailong
    Zhou, Haiyan
    Wang, Jing
    Li, Yansong
    Luo, Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (09): : 13639 - 13645
  • [29] Comparison of GlideScope video laryngoscope and intubating laryngeal mask airway with direct laryngoscopy for endotracheal intubation
    Cinar, Orhan
    Cevik, Erdem
    Yildirim, Ali Osman
    Yasar, Mehmet
    Kilic, Erden
    Comert, Bilgin
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2011, 18 (02) : 117 - 120
  • [30] Randomized comparison of the Pentax AirWay Scope and Macintosh laryngoscope for tracheal intubation in patients with obstructive sleep apnoea
    Kim, M. K.
    Park, S. W.
    Lee, J. W.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 662 - 666