Non enzymatic hydrogen peroxide detection at ruthenium oxide-gold nano particle-Nafion modified electrode

被引:28
|
作者
Anjalidevi, C. [1 ]
Dharuman, V. [1 ]
Narayanan, J. Shankara [1 ]
机构
[1] Alagappa Univ, Dept Bioelect & Biosensors, Mol Elect Lab, Karaikkudi 630003, Tamil Nadu, India
来源
关键词
Hydrogen peroxide; RuO2; AuNP; Non-enzymatic; Electrochemical; Nafion; ELECTROCATALYTIC OXIDATION; NANOPARTICLES; SENSOR; NANOSTRUCTURES; FABRICATION; GLUCOSE; FILM;
D O I
10.1016/j.snb.2013.03.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrated non-enzymatic detection of hydrogen peroxide (H2O2) at ruthenium oxide gold nano particle (RuO2-AuNP)-Nafion modified glassy carbon electrode in phosphate buffer. Porous RuO2 is embedded in the Nafion matrix, and the AuNPs are deposited by electrochemical reduction of tetrachloroaurate. The efficient interaction between RuO2 and AuNP, and the higher crystallinity of the RuO2-AuNP is proven by the appearance of (1 1 1) and (2 2 0) planes in the X-ray diffraction pattern of the RuO2-AuNPs that are found in addition to the (1 0 2) and (2 1 1) planes in the patterns of pure RuO2. Increased fractions (atomic percents) of Ru and Au are confirmed in energy dispersive X-ray spectroscopy. High-resolution scanning electron microscopy and atomic force microscopy (AFM) indicate the controlled deposition of the AuNPs on the RuO2 nanoparticles protruding the Nafion film. The composite reduces the H2O2 at -0.14V (vs. Ag/AgCl). The composite behavior is compared with the Nafion-AuNP and Nafion-RuO2 composites. Examination of solution pH and H2O2 concentration revealed enzyme mimetic behavior of the Nafion-RuO2-AuNP and showed 20 times higher Michaelis-Menten kinetic constant K-M (10.1 mM) than the previously reported MnO2 based non-enzymatic H2O2 sensor. The composite is highly selective in presence of potential interferences such as ascorbic acid, uric acid, catechol and dopamine. The sensors showed a dynamic range of 0.1 nM to 30 mM per liter with the lowest detection limit 0.1 x 10(-9) M. The method is used to determine the concentration of H2O2 in an antiseptic solution. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 263
页数:8
相关论文
共 50 条
  • [41] A hydrogen peroxide biosensor based on nano-Au/PAMAM dendrimer/cystamine modified gold electrode
    Liu, ZM
    Yang, Y
    Wang, H
    Liu, YL
    Shen, GL
    Yu, RQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01) : 394 - 400
  • [42] Non-enzymatic electrochemical sensing of glucose and hydrogen peroxide using a bis(acetylacetonato) oxovanadium(IV) complex modified gold electrode
    Barman, Koushik
    Jasimuddin, Sk
    RSC ADVANCES, 2016, 6 (25) : 20800 - 20806
  • [43] Non-enzymatic amperometric detection of hydrogen peroxide in human blood serum samples using a modified silver nanowire electrode
    Thirumalraj, Balamurugan
    Zhao, Duo-Han
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 470 : 117 - 122
  • [44] N-Hydroxysuccinimide crosslinked graphene oxide-gold nanoflower modified SPE electrode for sensitive detection of chloramphenicol antibiotic
    Ali, M. R.
    Bacchu, M. S.
    Al-Mamun, M. R.
    Ahommed, M. S.
    Aly, M. Aly Saad
    Khan, M. Z. H.
    RSC ADVANCES, 2021, 11 (26) : 15565 - 15572
  • [45] Electrosynthesis of bismuth nanodendrites/gallium nitride electrode for non-enzymatic hydrogen peroxide detection
    Jiang, Qing-Mei
    Zhang, Miao-Rong
    Luo, Li-Qiang
    Pan, Ge-Bo
    TALANTA, 2017, 171 : 250 - 254
  • [46] Polyethylenimine-bridged graphene oxide-gold film on glassy carbon electrode and its electrocatalytic activity toward nitrite and hydrogen peroxide
    Yuan, Baiqing
    Xu, Chunying
    Liu, Lin
    Shi, Yunfeng
    Li, Sujuan
    Zhang, Renchun
    Zhang, Daojun
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 55 - 61
  • [47] Gold Nano Particle and Reduced Graphene Oxide Composite Modified Carbon Paste Electrode for the Ultra Trace Detection of Arsenic (III)
    Sahoo, Srikant
    Sahoo, Prasanta Kumar
    Satpati, Ashis Kumar
    ELECTROANALYSIS, 2017, 29 (05) : 1400 - 1409
  • [48] A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 398 - 406
  • [49] Electrochemical performance of ruthenium nanoparticles decorated on nitride carbon for non-enzymatic detection of hydrogen peroxide
    Cheng, Xia
    Xu, Caili
    Chen, Qian
    Wang, Yi
    Zhang, Yun
    Fan, Guangyin
    ANALYST, 2019, 144 (22) : 6706 - 6711
  • [50] Synthesis, characterization of copper oxide-gold nanoalloys and their peroxidase-like activity towards colorimetric detection of hydrogen peroxide and glucose
    Mvango, Sindisiwe
    Mashazi, Philani
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 96 : 814 - 823