Non enzymatic hydrogen peroxide detection at ruthenium oxide-gold nano particle-Nafion modified electrode

被引:28
|
作者
Anjalidevi, C. [1 ]
Dharuman, V. [1 ]
Narayanan, J. Shankara [1 ]
机构
[1] Alagappa Univ, Dept Bioelect & Biosensors, Mol Elect Lab, Karaikkudi 630003, Tamil Nadu, India
来源
关键词
Hydrogen peroxide; RuO2; AuNP; Non-enzymatic; Electrochemical; Nafion; ELECTROCATALYTIC OXIDATION; NANOPARTICLES; SENSOR; NANOSTRUCTURES; FABRICATION; GLUCOSE; FILM;
D O I
10.1016/j.snb.2013.03.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrated non-enzymatic detection of hydrogen peroxide (H2O2) at ruthenium oxide gold nano particle (RuO2-AuNP)-Nafion modified glassy carbon electrode in phosphate buffer. Porous RuO2 is embedded in the Nafion matrix, and the AuNPs are deposited by electrochemical reduction of tetrachloroaurate. The efficient interaction between RuO2 and AuNP, and the higher crystallinity of the RuO2-AuNP is proven by the appearance of (1 1 1) and (2 2 0) planes in the X-ray diffraction pattern of the RuO2-AuNPs that are found in addition to the (1 0 2) and (2 1 1) planes in the patterns of pure RuO2. Increased fractions (atomic percents) of Ru and Au are confirmed in energy dispersive X-ray spectroscopy. High-resolution scanning electron microscopy and atomic force microscopy (AFM) indicate the controlled deposition of the AuNPs on the RuO2 nanoparticles protruding the Nafion film. The composite reduces the H2O2 at -0.14V (vs. Ag/AgCl). The composite behavior is compared with the Nafion-AuNP and Nafion-RuO2 composites. Examination of solution pH and H2O2 concentration revealed enzyme mimetic behavior of the Nafion-RuO2-AuNP and showed 20 times higher Michaelis-Menten kinetic constant K-M (10.1 mM) than the previously reported MnO2 based non-enzymatic H2O2 sensor. The composite is highly selective in presence of potential interferences such as ascorbic acid, uric acid, catechol and dopamine. The sensors showed a dynamic range of 0.1 nM to 30 mM per liter with the lowest detection limit 0.1 x 10(-9) M. The method is used to determine the concentration of H2O2 in an antiseptic solution. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 263
页数:8
相关论文
共 50 条
  • [11] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [12] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    Microchimica Acta, 2014, 181 : 1463 - 1470
  • [13] Immobilized horseradish peroxidase on Nafion-cysteine modified gold electrode as a biosensor for hydrogen peroxide
    Ghourchian, Hedayatollah
    Hong, Jun
    Hamidi, Faezeh
    CLINICAL BIOCHEMISTRY, 2011, 44 (13) : S96 - S96
  • [14] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Cong Zhang
    Haohai Jiang
    Rui Ma
    Yanyan Zhang
    Qiang Chen
    Ionics, 2017, 23 : 1309 - 1317
  • [15] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Zhang, Cong
    Jiang, Haohai
    Ma, Rui
    Zhang, Yanyan
    Chen, Qiang
    IONICS, 2017, 23 (05) : 1309 - 1317
  • [16] MWCNT-cysteamine-Nafion modified gold electrode based on myoglobin for determination of hydrogen peroxide and nitrite
    Canbay, Erhan
    Sahin, Berika
    Kiran, Muge
    Akyilmaz, Erol
    BIOELECTROCHEMISTRY, 2015, 101 : 126 - 131
  • [17] Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor
    Priya, C.
    Sivasankari, G.
    Narayanan, S. Sriman
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 : 90 - 96
  • [18] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [19] Ruthenium/rhodium modified gold electrodes for the amperometric detection of hydrogen peroxide at low potentials
    Janasek, Dirk
    Vastarella, Walter
    Spohn, Uwe
    Teuscher, Nico
    Heilmann, Andreas
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (7-8) : 1267 - 1273
  • [20] Ruthenium/rhodium modified gold electrodes for the amperometric detection of hydrogen peroxide at low potentials
    Dirk Janasek
    Walter Vastarella
    Uwe Spohn
    Nico Teuscher
    Andreas Heilmann
    Analytical and Bioanalytical Chemistry, 2002, 374 : 1267 - 1273