Non enzymatic hydrogen peroxide detection at ruthenium oxide-gold nano particle-Nafion modified electrode

被引:28
|
作者
Anjalidevi, C. [1 ]
Dharuman, V. [1 ]
Narayanan, J. Shankara [1 ]
机构
[1] Alagappa Univ, Dept Bioelect & Biosensors, Mol Elect Lab, Karaikkudi 630003, Tamil Nadu, India
来源
关键词
Hydrogen peroxide; RuO2; AuNP; Non-enzymatic; Electrochemical; Nafion; ELECTROCATALYTIC OXIDATION; NANOPARTICLES; SENSOR; NANOSTRUCTURES; FABRICATION; GLUCOSE; FILM;
D O I
10.1016/j.snb.2013.03.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrated non-enzymatic detection of hydrogen peroxide (H2O2) at ruthenium oxide gold nano particle (RuO2-AuNP)-Nafion modified glassy carbon electrode in phosphate buffer. Porous RuO2 is embedded in the Nafion matrix, and the AuNPs are deposited by electrochemical reduction of tetrachloroaurate. The efficient interaction between RuO2 and AuNP, and the higher crystallinity of the RuO2-AuNP is proven by the appearance of (1 1 1) and (2 2 0) planes in the X-ray diffraction pattern of the RuO2-AuNPs that are found in addition to the (1 0 2) and (2 1 1) planes in the patterns of pure RuO2. Increased fractions (atomic percents) of Ru and Au are confirmed in energy dispersive X-ray spectroscopy. High-resolution scanning electron microscopy and atomic force microscopy (AFM) indicate the controlled deposition of the AuNPs on the RuO2 nanoparticles protruding the Nafion film. The composite reduces the H2O2 at -0.14V (vs. Ag/AgCl). The composite behavior is compared with the Nafion-AuNP and Nafion-RuO2 composites. Examination of solution pH and H2O2 concentration revealed enzyme mimetic behavior of the Nafion-RuO2-AuNP and showed 20 times higher Michaelis-Menten kinetic constant K-M (10.1 mM) than the previously reported MnO2 based non-enzymatic H2O2 sensor. The composite is highly selective in presence of potential interferences such as ascorbic acid, uric acid, catechol and dopamine. The sensors showed a dynamic range of 0.1 nM to 30 mM per liter with the lowest detection limit 0.1 x 10(-9) M. The method is used to determine the concentration of H2O2 in an antiseptic solution. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 263
页数:8
相关论文
共 50 条
  • [1] Ruthenium oxide hexacyanoferrate modified electrode for hydrogen peroxide detection
    Paixao, Thiago R. L. C.
    Bertotti, Mauro
    ELECTROANALYSIS, 2008, 20 (15) : 1671 - 1677
  • [2] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Chandrasekaran Priya
    Sriraman Anuja
    Mani Devendiran
    Rajendran Suresh Babu
    Sangilimuthu Sriman Narayanan
    Ionics, 2024, 30 : 2869 - 2880
  • [3] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Priya, Chandrasekaran
    Anuja, Sriraman
    Devendiran, Mani
    Babu, Rajendran Suresh
    Narayanan, Sangilimuthu Sriman
    IONICS, 2024, 30 (05) : 2869 - 2880
  • [4] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Yan, Zhongke
    Zhao, Jianwei
    Qin, Lirong
    Mu, Fan
    Wang, Ping
    Feng, Xining
    MICROCHIMICA ACTA, 2013, 180 (1-2) : 145 - 150
  • [5] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Zhongke Yan
    Jianwei Zhao
    Lirong Qin
    Fan Mu
    Ping Wang
    Xining Feng
    Microchimica Acta, 2013, 180 : 145 - 150
  • [6] Nafion/Polypyrrole Blends for Non Enzymatic Detection of Hydrogen Peroxide
    Arena, A.
    Scandurra, G.
    Ciofi, C.
    Saitta, G.
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS II, 2013, 543 : 255 - 260
  • [7] Graphene oxide-gold nanozyme for highly sensitive electrochemical detection of hydrogen peroxide
    Jin, Ga Hyun
    Ko, Euna
    Kim, Min Ki
    Tran, Van-Khue
    Son, Seong Eun
    Geng, Yanfang
    Hur, Won
    Seong, Gi Hun
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 274 : 201 - 209
  • [8] Electrosynthesis of gold nanoparticles/porous GaN electrode for non-enzymatic hydrogen peroxide detection
    Zhang, Miao-Rong
    Chen, Xue-Qing
    Pan, Ge-Bo
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 142 - 147
  • [9] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    Chemical Papers, 2014, 68 : 435 - 441
  • [10] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441