Objective To assess the accuracy of three-dimensional electron beam CT angiography (3D-EBCTA) in the detection of intracranial aneurysms. Methods 31 patients with suspected cerebral aneurysms (including 3 post-operative patients) were examined by 3D-EBCTA. Those receiving angiography or surgery acted as controls. Maximum intensity projection (MIP) and shaded surface display (SSD) reconstruction ways were selected. Results 24 aneurysms were found in 23 patients. Of the 31 patients, false positive was noted in 1 patient, and false negative in 2 on 3D-EBCTA. The sensitivity, specificity, accuracy, positive predictive value anal negative predictive value were 92.0%, 88.9%, 91.2%, 95.8% and 80.0% respectively. Conclusion 3D-EBCTA is an noninvasive, rapid, valuable method in diagnosis and screening of patients with suspected aneurysms. The reconstruction modes such as MIP and SSD should be used together to optimise the visualization.
引用
收藏
页码:739 / 742
页数:4
相关论文
共 50 条
  • [41] Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional magnetic resonance angiography
    Arimura, H
    Li, Q
    Korogi, Y
    Hirai, T
    Abe, H
    Yamashita, Y
    Katsuragawa, S
    Ikeda, R
    Doi, K
    ACADEMIC RADIOLOGY, 2004, 11 (10) : 1093 - 1104
  • [42] Three-dimensional reconstructed images after rotational angiography in the evaluation of intracranial aneurysms: Surgical correlation
    Tanoue, S
    Kiyosue, H
    Kenai, H
    Nakamura, T
    Yamashita, M
    Mori, H
    NEUROSURGERY, 2000, 47 (04) : 866 - 871
  • [43] Limitations of three-dimensional reconstructed computerized tomography angiography after clip placement for intracranial aneurysms
    Sagara, Y
    Kiyosue, H
    Hori, Y
    Sainoo, M
    Nagatomi, H
    Mori, H
    JOURNAL OF NEUROSURGERY, 2005, 103 (04) : 656 - 661
  • [44] Preliminary evaluation of volume-rendered three-dimensional display of time-of-flight MR angiography in the diagnosis of intracranial aneurysms
    Tsuchiya, K
    Katase, S
    Yoshino, A
    Hachiya, J
    Yodo, K
    NEURORADIOLOGY, 2001, 43 (08) : 633 - 636
  • [45] Preliminary evaluation of volume-rendered three-dimensional display of time-of-flight MR angiography in the diagnosis of intracranial aneurysms
    K. Tsuchiya
    S. Katase
    A. Yoshino
    J. Hachiya
    K. Yodo
    Neuroradiology, 2001, 43 : 633 - 636
  • [46] Diagnosis of unruptured cerebral aneurysms using magnetic resonance angiography and three-dimensional computed tomographic angiography
    Okuyama, T
    Saito, K
    Hirano, A
    Takahashi, A
    Hashimoto, Y
    Inagaki, T
    NEUROLOGICAL SURGERY, 1997, 25 (12): : 1073 - 1079
  • [47] Depicting cerebral veins by three-dimensional CT angiography before surgical clipping of aneurysms
    Kaminogo, M
    Hayashi, H
    Ishimaru, H
    Morikawa, M
    Kitagawa, N
    Matsuo, Y
    Hayashi, K
    Yoshioka, T
    Shibata, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (01) : 85 - 91
  • [48] Application of three-dimensional CT angiography (3D-CTA) to cerebral aneurysms
    Kato, Y
    Sano, H
    Katada, K
    Ogura, Y
    Hayakawa, M
    Kanaoka, N
    Kanno, T
    SURGICAL NEUROLOGY, 1999, 52 (02): : 113 - 121
  • [49] Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice helical computed tomographic angiography - Comments
    Solomon, RA
    Satow, T
    Hashimoto, N
    Seifert, V
    Beck, J
    Hoh, BL
    Ogilvy, CS
    NEUROSURGERY, 2004, 54 (02) : 340 - 341
  • [50] Effects of three-dimensional angiography on the coiling of cerebral aneurysms
    Albuquerque, FC
    Spetzler, RF
    Zabramski, JM
    McDougall, CG
    NEUROSURGERY, 2002, 51 (03) : 597 - 605