Three-dimensional electron beam CT angiography in the diagnosis of intracranial aneurysms

被引:0
|
作者
Chen, S [1 ]
Shen, TZ [1 ]
Chen, XR [1 ]
机构
[1] Shanghai Med Univ, Dept Radiol, Huashan Hosp, Shanghai 200040, Peoples R China
关键词
three-dimensional electron beam; CT; angiography; intracranial aneurysms;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To assess the accuracy of three-dimensional electron beam CT angiography (3D-EBCTA) in the detection of intracranial aneurysms. Methods 31 patients with suspected cerebral aneurysms (including 3 post-operative patients) were examined by 3D-EBCTA. Those receiving angiography or surgery acted as controls. Maximum intensity projection (MIP) and shaded surface display (SSD) reconstruction ways were selected. Results 24 aneurysms were found in 23 patients. Of the 31 patients, false positive was noted in 1 patient, and false negative in 2 on 3D-EBCTA. The sensitivity, specificity, accuracy, positive predictive value anal negative predictive value were 92.0%, 88.9%, 91.2%, 95.8% and 80.0% respectively. Conclusion 3D-EBCTA is an noninvasive, rapid, valuable method in diagnosis and screening of patients with suspected aneurysms. The reconstruction modes such as MIP and SSD should be used together to optimise the visualization.
引用
收藏
页码:739 / 742
页数:4
相关论文
共 50 条
  • [31] Hepatic artery aneurysms: Evaluation using three-dimensional spiral CT angiography
    Howling, SJ
    Gordon, H
    McArthur, T
    Hatfield, A
    Lees, WR
    CLINICAL RADIOLOGY, 1997, 52 (03) : 227 - 230
  • [32] Sub-millimeter three-dimensional CT angiography in the detection of cerebral aneurysms
    Katada, K
    Hayakawa, M
    Takeshita, G
    Ogura, Y
    Kato, R
    Koga, S
    RADIOLOGY, 1998, 209P : 156 - 156
  • [33] Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice helical computed tomographic angiography
    Kangasniemi, M
    Mäkelä, T
    Koskinen, S
    Porras, M
    Poussa, K
    Hernesniemi, J
    NEUROSURGERY, 2004, 54 (02) : 336 - 340
  • [34] Accuracy assessment of CT angiography for three-dimensional measurement of intracranial aneurysm geometry
    Sato, Y
    Quets, JP
    Sickels, WJ
    Traynalis, VC
    Loftus, CM
    Follett, KA
    RADIOLOGY, 1997, 205 : 163 - 163
  • [35] Electron-beam CT angiography with three-dimensional reconstruction in the evaluation of coronary artery bypass grafts
    Dai, RP
    Zhang, SX
    Lu, B
    Cao, C
    He, S
    Bai, H
    Jing, BL
    ACADEMIC RADIOLOGY, 1998, 5 (12) : 863 - 867
  • [36] Three-dimensional digital subtraction angiography vs two-dimensional digital subtraction angiography for detection of ruptured intracranial aneurysms:: a study of 86 aneurysms
    Kawashima, M
    Kitahara, T
    Soma, K
    Fujii, K
    NEUROLOGY INDIA, 2005, 53 (03) : 287 - 289
  • [37] The effects of image quality on three-dimensional electron beam coronary angiography
    Lu, B
    Hamid, B
    Mao, S
    Zhuang, N
    Yamamoto, H
    Liu, SCK
    Budoff, MJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 495A - 495A
  • [38] Gadolinium-enhanced three-dimensional electron beam coronary angiography
    Budoff, MJ
    Lu, B
    Mao, SS
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) : 879 - 879
  • [39] Assessment of the Risk of Rupture of Intracranial Aneurysms using Three-dimensional Cerebral Digital Subtraction Angiography
    Yu, J.
    Wu, Q.
    Ma, F-Q
    Xu, J.
    Zhang, J-M
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2010, 38 (05) : 1785 - 1794
  • [40] Three-dimensional volume rendering for magnetic resonance angiography in the screening and preoperative workup of intracranial aneurysms
    Maeder, PP
    Meuli, RA
    deTribolet, N
    JOURNAL OF NEUROSURGERY, 1996, 85 (06) : 1050 - 1055