Optimising fluorescein diacetate sputum smear microscopy for assessing patients with pulmonary tuberculosis

被引:3
|
作者
Datta, Sumona [1 ,2 ,3 ]
Alvarado, Keren [2 ]
Gilman, Robert H. [4 ]
Valencia, Teresa [2 ]
Aparicio, Christian [2 ]
Ramos, Eric S. [2 ]
Montoya, Rosario [2 ,3 ]
Evans, Carlton A. [1 ,2 ,3 ]
机构
[1] Imperial Coll London, Wellcome Trust Ctr Global Hlth Res, Infect Dis & Immun, London, England
[2] Univ Peruana Cayetano Heredia, Lab Res & Dev, IFHAD Innovat Hlth & Dev, Lima, Peru
[3] Asociac Benefica Prisma, IPSYD, Lima, Peru
[4] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Int Hlth, Baltimore, MD USA
来源
PLOS ONE | 2019年 / 14卷 / 04期
基金
英国惠康基金; 比尔及梅琳达.盖茨基金会; 美国国家卫生研究院;
关键词
DIAGNOSIS; INFECTIOUSNESS;
D O I
10.1371/journal.pone.0214131
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings. Methods and results Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4 degrees C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy. Conclusions We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Determinants of sputum smear nonconversion in smear-positive pulmonary tuberculosis patients in Suriname, 2010-2015
    Commiesie, Eric
    Stijnberg, Deborah
    Marin, Diana
    Perez, Freddy
    Sanchez, Mauro
    REVISTA PANAMERICANA DE SALUD PUBLICA-PAN AMERICAN JOURNAL OF PUBLIC HEALTH, 2019, 43
  • [42] Induced sputum in the diagnosis of smear-negative pulmonary tuberculosis
    Nguyen, Minh Sang
    Phan, Thu Phuong
    RESPIROLOGY, 2023, 28 : 377 - 377
  • [43] In Pulmonary Tuberculosis Direct Smear Sputum Is a Prognostic Factor for Cure
    Leon-Abarca, J. A.
    Accinelli Tanaka, R. A.
    Lopez, M.
    Ascarza, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [44] Same-day sputum smear microscopy for the diagnosis of pulmonary tuberculosis: direct vs. concentrated sputum smear (vol 20, pg 247, 2016)
    Chandra, T. J.
    Selvaraj, R.
    Sharma, Y. V.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2016, 20 (04) : 568 - 568
  • [45] EFFECTS OF HOUSEHOLD BLEACH ON SPUTUM SMEAR MICROSCOPY TO CONCENTRATE ACID FAST BACILLI FOR THE DIAGNOSIS OF PULMONARY TUBERCULOSIS
    Rasool, G.
    Riaz, M.
    Mahmood, Z.
    Mohy-Ud-Din, R.
    Akhtar, J.
    Javed, I.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2018, 32 (03): : 607 - 611
  • [46] Implications of post-bronchoscopy sputum smear in pulmonary tuberculosis
    Thomas, Benjamin S.
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2012, 44 (12) : 1005 - 1006
  • [48] Factors Influencing Sputum Smear Conversion among Smear Positive Pulmonary Tuberculosis Patients in Kandahar City, Afghanistan
    Stanikzai, Muhammad Haroon
    Bairwa, Mohan
    Wasiq, Abdul Wahed
    Gupta, Shiv Dutt
    Akbari, Khalid
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (10)
  • [49] Time between sputum examination and treatment in patients with smear-negative pulmonary tuberculosis
    Salaniponi, FML
    Gausi, F
    Kwanjana, JH
    Harries, AD
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2000, 4 (06) : 581 - 583
  • [50] The diagnosis of smear-negative pulmonary tuberculosis: the practice of sputum smear examination in Malawi
    Harries, AD
    Nyirenda, TE
    Banerjee, A
    Boeree, MJ
    Salaniponi, FML
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 1999, 3 (10) : 896 - 900