Optimising fluorescein diacetate sputum smear microscopy for assessing patients with pulmonary tuberculosis

被引:3
|
作者
Datta, Sumona [1 ,2 ,3 ]
Alvarado, Keren [2 ]
Gilman, Robert H. [4 ]
Valencia, Teresa [2 ]
Aparicio, Christian [2 ]
Ramos, Eric S. [2 ]
Montoya, Rosario [2 ,3 ]
Evans, Carlton A. [1 ,2 ,3 ]
机构
[1] Imperial Coll London, Wellcome Trust Ctr Global Hlth Res, Infect Dis & Immun, London, England
[2] Univ Peruana Cayetano Heredia, Lab Res & Dev, IFHAD Innovat Hlth & Dev, Lima, Peru
[3] Asociac Benefica Prisma, IPSYD, Lima, Peru
[4] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Int Hlth, Baltimore, MD USA
来源
PLOS ONE | 2019年 / 14卷 / 04期
基金
英国惠康基金; 比尔及梅琳达.盖茨基金会; 美国国家卫生研究院;
关键词
DIAGNOSIS; INFECTIOUSNESS;
D O I
10.1371/journal.pone.0214131
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings. Methods and results Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4 degrees C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy. Conclusions We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Sensitivity of direct versus concentrated sputum smear microscopy in HIV-infected patients suspected of having pulmonary tuberculosis
    Cattamanchi, Adithya
    Dowdy, David W.
    Davis, J. Lucian
    Worodria, William
    Yoo, Samuel
    Joloba, Moses
    Matovu, John
    Hopewell, Philip C.
    Huang, Laurence
    BMC INFECTIOUS DISEASES, 2009, 9
  • [32] Sensitivity of direct versus concentrated sputum smear microscopy in HIV-infected patients suspected of having pulmonary tuberculosis
    Adithya Cattamanchi
    David W Dowdy
    J Lucian Davis
    William Worodria
    Samuel Yoo
    Moses Joloba
    John Matovu
    Philip C Hopewell
    Laurence Huang
    BMC Infectious Diseases, 9
  • [33] Sputum smear-positive pulmonary tuberculosis: Is sputum smear examination required to discontinue airborne precautions?
    Argemi, X.
    Albrecht, M.
    Hansmann, Y.
    Jaulhac, B.
    Koebel, C.
    Schramm, F.
    MEDECINE ET MALADIES INFECTIEUSES, 2015, 45 (10): : 411 - 413
  • [34] Sputum Smear Grading: A Factor To Predict Treatment Outcome In New Sputum Smear Positive Pulmonary Tuberculosis
    Chopra, V.
    Mascarenhas, D. G.
    Chahal, A. S.
    Mahi, K.
    Kansal, A. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [35] Time to Sputum Smear Conversion in Smear-Positive Pulmonary Tuberculosis Patients and Factors for Delayed Conversion
    Azarkar, Zohreh
    Sharifzadeh, Gholamreza
    Ebrahimzadeh, Azade
    Olumi, Saeeid
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2016, 41 (01) : 44 - 47
  • [36] Evaluation of autofocus functions of conventional sputum smear microscopy for tuberculosis
    Kimura Junior, Almir
    Costa, Marly G. F.
    Costa Filho, Cicero F. F.
    Fujimoto, Luciana B. M.
    Salem, Julia
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3041 - 3044
  • [37] Same day sputum smear microscopy approach with modified ZN staining for the diagnosis of pulmonary tuberculosis in a microscopy centre at Rajahmundry
    Chandra, T. J.
    Raj, R. S.
    Sharma, Y. V.
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 32 (02) : 153 - 156
  • [38] Sputum smears for diagnosis of smear-positive pulmonary tuberculosis
    Harries, AD
    Kamenya, A
    Subramanyam, VR
    Salaniponi, FM
    Nyangulu, DS
    LANCET, 1996, 347 (9004): : 834 - 835
  • [39] Role of Sputum Smear in Predicting Culture Results in Pulmonary Tuberculosis
    Sajid, Mansoor Ud Din
    Siddique, Muhammad
    Rehman, Abdur
    Yaqoob, Muhammad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2014, 8 (01): : 60 - 62
  • [40] Comparison of yield in sputum smear microscopy from specimens collected at different times in the diagnosis of pulmonary tuberculosis
    Kudzawu, S.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2012, 17 : 23 - 23