Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves

被引:12
|
作者
Xuan, Yue [1 ,2 ]
Dvir, Danny [3 ]
Wang, Zhongjie [1 ,2 ]
Ye, Jian [4 ]
Guccione, Julius M. [1 ,2 ]
Ge, Liang [1 ,2 ]
Tseng, Elaine E. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Div Cardiothorac Surg, 500 Parnassus Ave,Suite 405W,Box 0118, San Francisco, CA 94143 USA
[2] San Francisco VA Med Ctr, 500 Parnassus Ave,Suite 405W,Box 0118, San Francisco, CA 94143 USA
[3] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[4] St Pauls Hosp, Dept Surg, Vancouver, BC, Canada
基金
美国国家卫生研究院;
关键词
Transcatheter heart valve; Balloon expandable; Computational simulation; Durability; REPLACEMENT; DURABILITY;
D O I
10.1093/icvts/ivaa037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Transcatheter aortic valve replacement (TAVR) is established therapy for severe aortic stenosis patients with intermediate-, high- and prohibitive-risk for surgery. A significant challenge when expanding TAVR to low-risk and younger patients is the unknown long-term durability. High leaflet stresses have been associated with surgical bioprosthetic valve degeneration. In this study, we examined the impact of changes in valve design across 3 generations of same-sized TAVR devices on stent and leaflet stresses. METHODS: The 26-mm Edwards SAPIEN, 23, 26 and 29mm SAPIEN XT (XT) and 26mm SAPIEN 3 (S3) (n = 1 each) underwent micro-computed tomography (micro-CT) scanning. Dynamic finite element computational simulations of 23-26mm SAPIEN, 23-29mm XT and 23-29mm S3 were performed with physiological loading and micro-CT or scaled geometries. RESULTS: Peak stresses were concentrated in the commissure area and along the bottom of the suture, representing areas most likely to develop structural valve degeneration across TAVR generations. Latest-generation S3 showed greatest 99th percentile principal stress on commissural leaflets for 26 and 29 mm, and increased stresses over XT for 23 mm. Percentage of higher stress areas within the leaflets steadily increased across generations, 3.8%, 3.9% and 5.7%, respectively, for 26mm SAPIEN, XT and S3 with similar trend for 29-mm valves. CONCLUSIONS: Using computational simulations based on high-fidelity modelling of balloon-expandable TAVRs, our study demonstrated that maximum stress areas existed in similar leaflet locations across SAPIEN generations, while the latest model S3 had the highest magnitude for both 26- and 29-mm valves. S3 also had the largest area of higher stresses than other generations, which would be prone to degeneration. Our study coupled with future long-term clinical outcomes >10 years will provide insight on biomechanics of TAVR degeneration.
引用
收藏
页码:879 / 886
页数:8
相关论文
共 50 条
  • [41] LONG-TERM OUTCOMES OF BALLOON-EXPANDABLE VERSUS SELF-EXPANDING TRANSCATHETER AORTIC VALVES
    Patail, Haris
    Kompella, Ritika
    Bihag, Zade
    Haider, Jawad
    Lorenz, David P.
    Piccirillo, Bryan
    Azemi, Talhat
    Hoover, Nicole
    Hagberg, Robert
    Mather, Jeffrey
    Hashim, Sabet
    McKay, Raymond G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 974 - 974
  • [42] BALLOON-EXPANDABLE STENT OCCLUDER
    MOSS, JG
    LABORDE, JC
    CLEM, MF
    RIVERA, FJ
    ENCARNACION, CE
    LUTZ, JD
    RADIOLOGY, 1992, 185 : 134 - 134
  • [43] A BALLOON-EXPANDABLE INTRAVASCULAR STENT FOR OBLITERATING EXPERIMENTAL AORTIC DISSECTION
    TRENT, MS
    PARSONNET, V
    SHOENFELD, R
    BRENER, BJ
    EISENBUD, DE
    NOVICK, AS
    CAMPBELL, AY
    FERRARARYAN, M
    VILLANUEVA, A
    JOURNAL OF VASCULAR SURGERY, 1990, 11 (05) : 707 - 717
  • [44] Quantitative Angiographic Assessment of Aortic Regurgitation after Transcatheter Aortic Valve Implantation among Three Balloon-Expandable Valves
    Kawashima, Hideyuki
    Wang, Rutao
    Mylotte, Darren
    Jagielak, Dariusz
    De Marco, Frederico
    Ielasi, Alfonso
    Onuma, Yoshinobu
    den Heijer, Peter
    Terkelsen, Christian Juhl
    Wijns, William
    Serruys, Patrick W.
    Soliman, Osama
    GLOBAL HEART, 2021, 16 (01)
  • [45] Self-Expandable vs Balloon-Expandable Valves in Patients With Small Annuli Undergoing Transfemoral Transcatheter Aortic Valve Implantation
    Hemelrijk, Kimberley
    Aarts, Hugo
    van Nieuwkerk, Astrid
    Broeze, Gijs
    Ruiz Quevedo, Valeriano
    Tchetche, Didier
    Sandoli, Fabio
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    D'Onofrio, Augusto
    Ribichini, Flavio
    Rocio, Huv
    Dumonteil, Nicolas
    Abizaid, Alexandre
    Sartori, Samantha
    d'Errigo, Paola
    Tarantini, Giuseppe
    del Sole, Paolo Alberto
    Orvin, Katia
    Pagnesi, Matteo
    Cruz Gonzalez, Ignacio
    Nombela-Franco, Luis
    Dangas, George
    Mehran, Roxana
    Voskuil, Michiel
    Delewi, Ronak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B396 - B397
  • [46] CLINICAL AND HEMODYNAMIC PERFORMANCE COMPARING BALLOON-EXPANDABLE AND SELF-EXPANDABLE TRANSCATHETER HEART VALVES IN PATIENTS WITH SMALL AORTIC ANNULI
    Moras, Errol C.
    Zaid, Syed
    Gandhi, Kruti Dhaval
    Khan, Safi
    Atkins, Marvin
    Reardon, Michael J.
    Kleiman, Neil
    Goel, Sachin S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 975 - 975
  • [47] Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Montone, Rocco A.
    Testa, Luca
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 235 - 236
  • [48] Comparison of latest generation transfemoral self-expandable and balloon-expandable transcatheter heart valves
    Schaefer, Andreas
    Linder, Matthias
    Seiffert, Moritz
    Schoen, Gerhard
    Deuschl, Florian
    Schofer, Niklas
    Schneeberger, Yvonne
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Schaefer, Ulrich
    Conradi, Lenard
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (06) : 905 - 911
  • [49] Comparison of balloon-expandable valves versus self-expandable valves in high-risk patients undergoing transcatheter aortic valve replacement for severe aortic stenosis
    Chang, Hsiao-Huang
    Chen, I-Ming
    Chen, Po-Lin
    Hsu, Tsui-Lieh
    Lin, Su-Man
    Chen, Ying-Hwa
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2015, 78 (06) : 331 - 338
  • [50] Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves
    Schaefer, Andreas
    Treede, Hendrik
    Seiffert, Moritz
    Deuschl, Florian
    Schofer, Niklas
    Schneeberger, Yvonne
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Schaefer, Ulrich
    Conradi, Lenard
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11