Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves

被引:12
|
作者
Xuan, Yue [1 ,2 ]
Dvir, Danny [3 ]
Wang, Zhongjie [1 ,2 ]
Ye, Jian [4 ]
Guccione, Julius M. [1 ,2 ]
Ge, Liang [1 ,2 ]
Tseng, Elaine E. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Div Cardiothorac Surg, 500 Parnassus Ave,Suite 405W,Box 0118, San Francisco, CA 94143 USA
[2] San Francisco VA Med Ctr, 500 Parnassus Ave,Suite 405W,Box 0118, San Francisco, CA 94143 USA
[3] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[4] St Pauls Hosp, Dept Surg, Vancouver, BC, Canada
基金
美国国家卫生研究院;
关键词
Transcatheter heart valve; Balloon expandable; Computational simulation; Durability; REPLACEMENT; DURABILITY;
D O I
10.1093/icvts/ivaa037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Transcatheter aortic valve replacement (TAVR) is established therapy for severe aortic stenosis patients with intermediate-, high- and prohibitive-risk for surgery. A significant challenge when expanding TAVR to low-risk and younger patients is the unknown long-term durability. High leaflet stresses have been associated with surgical bioprosthetic valve degeneration. In this study, we examined the impact of changes in valve design across 3 generations of same-sized TAVR devices on stent and leaflet stresses. METHODS: The 26-mm Edwards SAPIEN, 23, 26 and 29mm SAPIEN XT (XT) and 26mm SAPIEN 3 (S3) (n = 1 each) underwent micro-computed tomography (micro-CT) scanning. Dynamic finite element computational simulations of 23-26mm SAPIEN, 23-29mm XT and 23-29mm S3 were performed with physiological loading and micro-CT or scaled geometries. RESULTS: Peak stresses were concentrated in the commissure area and along the bottom of the suture, representing areas most likely to develop structural valve degeneration across TAVR generations. Latest-generation S3 showed greatest 99th percentile principal stress on commissural leaflets for 26 and 29 mm, and increased stresses over XT for 23 mm. Percentage of higher stress areas within the leaflets steadily increased across generations, 3.8%, 3.9% and 5.7%, respectively, for 26mm SAPIEN, XT and S3 with similar trend for 29-mm valves. CONCLUSIONS: Using computational simulations based on high-fidelity modelling of balloon-expandable TAVRs, our study demonstrated that maximum stress areas existed in similar leaflet locations across SAPIEN generations, while the latest model S3 had the highest magnitude for both 26- and 29-mm valves. S3 also had the largest area of higher stresses than other generations, which would be prone to degeneration. Our study coupled with future long-term clinical outcomes >10 years will provide insight on biomechanics of TAVR degeneration.
引用
收藏
页码:879 / 886
页数:8
相关论文
共 50 条
  • [32] Balloon-expandable or self-expandable transcatheter heart valves. Which are best?
    Webb, John
    Wood, David
    Sathananthan, Janarthanan
    Landes, Uri
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1900 - 1902
  • [33] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    VALUE IN HEALTH, 2021, 24 : S68 - S68
  • [34] Clinical Impact of Intraventricular Conduction Abnormalities After Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves
    Miura, Mizuki
    Shirai, Shinichi
    Uemura, Yukari
    Hayashi, Masaomi
    Takiguchi, Hiroshi
    Ito, Shinya
    Yano, Mariko
    Kawaguchi, Tomohiro
    Morinaga, Takashi
    Isotani, Akihiro
    Kakumoto, Shinichi
    Seo, Katsuhiro
    Arai, Yoshio
    Sakaguchi, Genichi
    Ando, Kenji
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 123 (02): : 297 - 305
  • [35] Prevention and Management of Transcatheter Balloon-Expandable Aortic Valve Malposition
    Al Ali, Abdullah M.
    Altwegg, Lukas
    Horlick, Eric M.
    Feindel, Christopher
    Thompson, Christopher R.
    Cheung, Anson
    Carere, Ronald G.
    Humphries, Karin
    Ye, Jian
    Masson, Jean-Bernard
    Webb, John G.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 573 - 578
  • [36] Transcatheter Aortic Valve Implantation Using the Slow Balloon Inflation Technique: Making Balloon-Expandable Valves Partially Repositionable
    Mok, Michael
    Dumont, Eric
    Doyle, Daniel
    Rodes-Cabau, Josep
    JOURNAL OF CARDIAC SURGERY, 2012, 27 (05) : 546 - 548
  • [37] Self-expanding vs. balloon-expandable transcatheter heart valves in small aortic annuli
    Kornyeva, Anastasiya
    Burri, Melchior
    Lange, Ruediger
    Ruge, Hendrik
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [38] BALLOON-EXPANDABLE INTRAVASCULAR STENT
    PALMAZ, JC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) : 1263 - 1269
  • [39] Very Late Migration of Balloon-Expandable Transcatheter Aortic Valve
    Kalra, Ankur
    Avenatti, Eleonora
    Chinnadurai, Ponraj
    Reardon, Michael J.
    Kleiman, Neal S.
    Little, Stephen H.
    Barker, Colin M.
    JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (04): : E28 - E30
  • [40] Short-Term outcomes using contemporary balloon-expandable valves in transcatheter aortic valve implantation
    Medranda, G.