Tapered double cantilever beam test used as a practical adhesion test for metal/adhesive/metal systems

被引:11
|
作者
Meiller, M [1 ]
Roche, AA [1 ]
Sautereau, H [1 ]
机构
[1] Inst Natl Sci Appl, Mat Macromol Lab, CNRS, UMR 5627, F-69621 Villeurbanne, France
关键词
practical adhesion; critical strain energy release rate; tapered double cantilever beam test; adhesional failure; epoxy-amine adhesive; rubber-modified adhesive;
D O I
10.1163/156856199X01009
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To quantify the practical adhesion between an epoxy-amine adhesive (DGEBA + IPD) and a titanium alloy (Ti6Al4V), a tapered double cantilever beam (TDCB) test was used. The critical strain energy release rate (G(Ic)) was evaluated. An appropriate size of the sample allows the fracture to propagate within the adhesive/metal interfacial region. The crosshead speed, the joint thickness, and the adhesive formulation all influence the experimental results. For low crosshead displacement speeds (< 1 mm min(-1)), the crack speed was controlled by the crosshead displacement. For higher crosshead displacement speeds, the crack propagation was controlled by the interfacial region critical strain energy release rate. By adding a reactive liquid rubber (ETBN 13) to the initial adhesive formulation, an increase in the critical strain energy release rate was observed.
引用
收藏
页码:773 / 788
页数:16
相关论文
共 50 条
  • [41] Beam Adjustment with Double Subwavelength Metal Slits Surrounded by Tapered Dielectric Gratings
    Zou Da-Qing
    Jiang Jian-Li
    Li Xiang-Yin
    CHINESE PHYSICS LETTERS, 2010, 27 (01)
  • [42] Study on quality evaluation test for adhesion of adhesives used for post - Installed adhesive anchor
    Sato K.
    Akiyama T.
    Hamasaki H.
    Journal of Structural and Construction Engineering, 2019, 84 (759): : 587 - 595
  • [43] An enhanced beam-theory model of the asymmetric double cantilever beam (ADCB) test for composite laminates
    Bennati, Stefano
    Colleluori, Massimiliano
    Corigliano, Domenico
    Valvo, Paolo S.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2009, 69 (11-12) : 1735 - 1745
  • [44] Guided Double Cantilever Beam test method for intermediate and high loading rates in composites
    Medina, S. A.
    Gonzalez, E. V.
    Blanco, N.
    Pernas-Sanchez, J.
    Artero-Guerrero, J. A.
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2023, 264
  • [45] MODIFIED DOUBLE-CANTILEVER BEAM TEST FOR SULFIDE STRESS CRACKING OF TUBULAR STEELS
    ASTAFJEV, VI
    SHMELEV, PS
    TETJUEVA, TV
    CORROSION, 1994, 50 (12) : 947 - 952
  • [46] Small-specimen double-cantilever-beam test applicable to monoliths and joints
    De With, G., 1600, Pharmacotherapy Publications Inc. (72):
  • [47] Application of the blister test to adhesion energy measurements in metal/ceramic film-on-substrate systems
    Dupeux, M
    Bosseboeuf, A
    INTERFACIAL SCIENCE IN CERAMIC JOINING, 1998, 58 : 319 - 327
  • [48] INTERFACE FRACTURE TOUGHNESS ASSESSMENT OF SOLDER JOINTS USING DOUBLE CANTILEVER BEAM TEST
    Loo, Shane Zhi Yuan
    Lee, Puay Cheng
    Lim, Zan Xuan
    Yantara, Natalia
    Tee, Tong Yan
    Tan, Cher Ming
    Chen, Zhong
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2010, 24 (1-2): : 164 - 174
  • [49] CONSTANT-K1 DOUBLE-CANTILEVER-BEAM TEST FOR CERAMIC MATERIALS
    NICHOLSON, PS
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1990, 73 (06) : 1800 - 1802