Thermoacoustic dosimetry of electron beam in extra field

被引:0
|
作者
Kalinichenko, AI
Kresnin, YA
Popov, GF
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The theoretical basis is elaborated for thermoacoustic dosimetry of electron beam by one-dimensional (1-D) thin target TT) in extra thermal and electromagnetic fields. The basic equation joining the deposited energy distribution to the stress wave amplitude in the cast when the generation coefficient is function of temperature and coordinate in material permits realizing nonlinear thermoacoustic dosimetry with regulated sensitivity. Some variants of joint employment of the thermoacoustic dosimeter and electromagnetic scanner/splitter are considered. The first variant consists in beam scanning along 1-D dosimeter body to create the moving thermoacoustic source. This regime may be used for dosimetry of long beams. The second variant consists in spectral decomposition of the beam in electromagnetic field before its directing to the dosimeter. Principle of operation for some thermoelastic dosimeters on the base of 1-D TTs is considered.
引用
收藏
页码:923 / 926
页数:4
相关论文
共 50 条
  • [1] CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY
    Nemtanu, M. R.
    Oproiu, C.
    Brasoveanu, M.
    Oane, M.
    ROMANIAN JOURNAL OF PHYSICS, 2009, 54 (7-8): : 613 - 617
  • [2] Small field electron beam dosimetry using MOSFET detector
    Amin, Md Nurul
    Heaton, Robert
    Norrlinger, Bern
    Islam, Mohammad K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (01): : 50 - 57
  • [3] Small Field Electron Beam Dosimetry Using MOSFET Detector
    Amin, M.
    Heaton, R.
    Norrlinger, B.
    Islam, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Polymer gel dosimetry of an electron beam in the presence of a magnetic field
    Vandecasteele, J.
    De Deene, Y.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [5] Practical considerations for electron beam small field size dosimetry
    Sharma, SC
    Johnson, MW
    Gossman, MS
    MEDICAL DOSIMETRY, 2005, 30 (02) : 104 - 106
  • [6] EXTRA-CAMERAL VOLUME EFFECTS IN IONIZATION CHAMBERS FOR ELECTRON-BEAM DOSIMETRY
    WILLIAMS, PC
    JORDAN, TJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (03): : 277 - 279
  • [7] Non-disturbing thermoacoustic dosimetry of electron and bremsstrahlung beams
    Kalinichenko, AI
    Popov, GF
    RADIATION PHYSICS AND CHEMISTRY, 2002, 63 (3-6) : 755 - 758
  • [8] PULSED ELECTRON BEAM DOSIMETRY
    OSWALD, RB
    EISEN, HA
    CONRAD, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (06) : 229 - &
  • [9] Characterizes of Microdetectors in Electron Beam Dosimetry
    Das, I.
    Andersen, A.
    Akino, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3477 - 3477
  • [10] Practical Aspects of Electron Beam Dosimetry
    Gerbi, B.
    MEDICAL PHYSICS, 2009, 36 (06)