Small field electron beam dosimetry using MOSFET detector

被引:18
|
作者
Amin, Md Nurul [1 ]
Heaton, Robert [1 ,2 ]
Norrlinger, Bern [1 ]
Islam, Mohammad K. [1 ,2 ]
机构
[1] Princess Margaret Hosp, Univ Hlth Network, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
来源
关键词
MOSFET; small field dosimetry; electron beams; TOTAL-BODY IRRADIATION; GAFCHROMIC EBT FILM; IN-VIVO DOSIMETRY; SENSITIVITY; DEPENDENCE; ENERGY; IMRT; KV;
D O I
10.1120/jacmp.v12i1.3267
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of d(max), and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becoming filmless in favor of electronic imaging, an alternate and readily available clinical dosimeter needs to be explored. We have studied the performance of MOSFET as a relative dosimeter in small field electron beams. The reproducibility, linearity and sensitivity of a high-sensitivity microMOSFET were investigated for clinical electron beams. In addition, the percent depth doses, output factors and profiles have been measured in a water tank with MOSFET and compared with those measured by an ion chamber for a range of field sizes from 1 cm diameter to 10 cm x 10 cm for 6, 12, 16 and 20 MeV beams. Similar comparative measurements were also performed with MOSFET and films in solid water phantom. The MOSFET sensitivity was found to be practically constant over the range of field sizes investigated. The dose response was found to be linear and reproducible ( within +/- 1% for 100 cGy). An excellent agreement was observed among the central axis depth dose curves measured using MOSFET, film and ion chamber. The output factors measured with MOSFET for small fields agreed to within 3% with those measured by film dosimetry. Overall results indicate that MOSFET can be utilized to perform dosimetry for small field electron beam.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 50 条
  • [1] Small Field Electron Beam Dosimetry Using MOSFET Detector
    Amin, M.
    Heaton, R.
    Norrlinger, B.
    Islam, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] In-Vivo Dosimetry Using a MOSFET Detector in an Anthropomorphic Phantom for Therapeutic Proton Beam
    Kohno, R.
    Hotta, K.
    Matsubara, K.
    Matsuura, T.
    Kameoka, S.
    Nisiho, T.
    Kawashima, M.
    Ogino, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Practical considerations for electron beam small field size dosimetry
    Sharma, SC
    Johnson, MW
    Gossman, MS
    MEDICAL DOSIMETRY, 2005, 30 (02) : 104 - 106
  • [4] Improvement of small-field electron beam dosimetry using Monte Carlo simulation
    Ma, CM
    Mok, E
    Kapur, A
    Findley, D
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 159 - 162
  • [5] Application of a diamond detector for electron beam dosimetry
    Rustgi, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1208 - 1208
  • [6] Characterization of a microSilicon diode detector for small-field photon beam dosimetry
    Akino, Yuichi
    Fujiwara, Masateru
    Okamura, Keita
    Shiomi, Hiroya
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Suzuki, Osamu
    Seo, Yuji
    Tamari, Keisuke
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (03) : 410 - 418
  • [7] Electron Beam Dosimetry Using a 2D Detector Array
    Srivastava, S.
    Das, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] SEMICONDUCTOR DETECTOR DOSIMETRY IN SMALL ELECTRON FIELDS
    RIKNER, G
    GRUSELL, E
    MEDICAL PHYSICS, 1986, 13 (04) : 609 - 609
  • [9] Dosimetry of a Small Field Electron Beam for Innovative Radiotherapy of Small Surface Or Internal Tumors
    Reft, C.
    Lu, Z.
    Noonan, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3411 - 3411
  • [10] Characteristics of microSilicon diode detector for electron beam dosimetry
    Akino, Yuichi
    Das, Indra J.
    Fujiwara, Masateru
    Kaneko, Akari
    Masutani, Takashi
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Suzuki, Osamu
    Seo, Yuji
    Tamari, Keisuke
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1130 - 1138