Small field electron beam dosimetry using MOSFET detector

被引:18
|
作者
Amin, Md Nurul [1 ]
Heaton, Robert [1 ,2 ]
Norrlinger, Bern [1 ]
Islam, Mohammad K. [1 ,2 ]
机构
[1] Princess Margaret Hosp, Univ Hlth Network, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
来源
关键词
MOSFET; small field dosimetry; electron beams; TOTAL-BODY IRRADIATION; GAFCHROMIC EBT FILM; IN-VIVO DOSIMETRY; SENSITIVITY; DEPENDENCE; ENERGY; IMRT; KV;
D O I
10.1120/jacmp.v12i1.3267
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of d(max), and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becoming filmless in favor of electronic imaging, an alternate and readily available clinical dosimeter needs to be explored. We have studied the performance of MOSFET as a relative dosimeter in small field electron beams. The reproducibility, linearity and sensitivity of a high-sensitivity microMOSFET were investigated for clinical electron beams. In addition, the percent depth doses, output factors and profiles have been measured in a water tank with MOSFET and compared with those measured by an ion chamber for a range of field sizes from 1 cm diameter to 10 cm x 10 cm for 6, 12, 16 and 20 MeV beams. Similar comparative measurements were also performed with MOSFET and films in solid water phantom. The MOSFET sensitivity was found to be practically constant over the range of field sizes investigated. The dose response was found to be linear and reproducible ( within +/- 1% for 100 cGy). An excellent agreement was observed among the central axis depth dose curves measured using MOSFET, film and ion chamber. The output factors measured with MOSFET for small fields agreed to within 3% with those measured by film dosimetry. Overall results indicate that MOSFET can be utilized to perform dosimetry for small field electron beam.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 50 条
  • [21] The influence of detector size relative to field size in small-field photon-beam dosimetry using synthetic diamond crystals as sensors
    Ade, N.
    Nam, T. L.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 113 : 6 - 13
  • [22] Small Electron Field Surface Dosimetry Using Solid State Detectors
    Tanny, S.
    Gautam, B.
    Pearson, D.
    Parsai, E.
    MEDICAL PHYSICS, 2012, 39 (06) : 3728 - 3728
  • [23] In Vivo Dosimetry with MOSFET Detector during Radiotherapy
    Cho, Sam Ju
    Kim, Won Taek
    Ki, Yong Gan
    Kwon, Soo Il
    Lee, Sang Hoon
    Do Huh, Hyun
    Cho, Kwang Hwan
    Kwon, Byung Hyun
    Kim, Dong Won
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1987 - +
  • [24] Micro-mosfet For Small-field In Vivo Dosimetry In Radiosurgery?
    Sors, A.
    Cassol, E.
    Latorzeff, I.
    Duthil, P.
    Lotterie, J.
    Redon, A.
    Berry, I.
    Franceries, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S870 - S870
  • [25] The 'cutting away' of potential secondary electron tracks explains the effects of beam size and detector wall density in small-field photon dosimetry
    Looe, Hui Khee
    Delfs, Bjoern
    Poppinga, Daniela
    Jiang, Ping
    Harder, Dietrich
    Poppe, Bjoern
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01):
  • [26] A Monte Carlo approach for small electron beam dosimetry
    Rincón, M
    Sánchez-Doblado, F
    Perucha, M
    Leal, A
    Arráns, R
    Carrasco, E
    Sánchez-Calzado, JA
    Errazquin, L
    RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) : 179 - 185
  • [27] CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY
    Nemtanu, M. R.
    Oproiu, C.
    Brasoveanu, M.
    Oane, M.
    ROMANIAN JOURNAL OF PHYSICS, 2009, 54 (7-8): : 613 - 617
  • [28] Characteristics and Effective Point of Measurement of a MicroSilicon Detector in Electron Beam Dosimetry
    Das, I.
    Srivastava, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E714 - E715
  • [29] Feasibility study of shielded diode detector for small field dosimetry
    Bharathan, Resmi K.
    Thasni, Irfana
    Musthafa, Musthafa
    Ayyappan, Suja Cheruliyil
    Ajaykumar, Silpa
    Jose, Lisha
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (11-12) : 1197 - 1201
  • [30] Dosimetry On Beam Modeling at the Small Field for Stereotactic Radiosurgery
    Jung, J.
    Kim, M.
    Yoon, D.
    Suh, T.
    MEDICAL PHYSICS, 2013, 40 (06)