Thermoacoustic dosimetry of electron beam in extra field

被引:0
|
作者
Kalinichenko, AI
Kresnin, YA
Popov, GF
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The theoretical basis is elaborated for thermoacoustic dosimetry of electron beam by one-dimensional (1-D) thin target TT) in extra thermal and electromagnetic fields. The basic equation joining the deposited energy distribution to the stress wave amplitude in the cast when the generation coefficient is function of temperature and coordinate in material permits realizing nonlinear thermoacoustic dosimetry with regulated sensitivity. Some variants of joint employment of the thermoacoustic dosimeter and electromagnetic scanner/splitter are considered. The first variant consists in beam scanning along 1-D dosimeter body to create the moving thermoacoustic source. This regime may be used for dosimetry of long beams. The second variant consists in spectral decomposition of the beam in electromagnetic field before its directing to the dosimeter. Principle of operation for some thermoelastic dosimeters on the base of 1-D TTs is considered.
引用
收藏
页码:923 / 926
页数:4
相关论文
共 50 条
  • [31] Practical approach to electron beam dosimetry at extended SSD
    Cygler, J
    Li, XA
    Ding, GX
    Lawrence, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08): : 1505 - 1514
  • [32] A new approach to electron-beam reference dosimetry
    Rogers, DWO
    MEDICAL PHYSICS, 1998, 25 (03) : 310 - 320
  • [33] A NEW MODEL FOR CLINICAL ELECTRON-BEAM DOSIMETRY
    VANDEGEIJN, J
    ARORA, BC
    MEDICAL PHYSICS, 1986, 13 (05) : 783 - 783
  • [34] A STUDY ON SECONDARY ELECTRONS IN ELECTRON-BEAM DOSIMETRY
    KRITHIVAS, G
    RAO, SN
    MEDICAL PHYSICS, 1986, 13 (05) : 780 - 780
  • [35] Electron beam Dosimetry using a computed radiography system
    Olch, A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2097 - 2097
  • [36] CONCERNING THE PERTURBATION CORRECTION IN ELECTRON-BEAM DOSIMETRY
    SCHULZ, RJ
    MEDICAL PHYSICS, 1982, 9 (01) : 131 - 131
  • [37] Photon and electron beam dosimetry with a CVD diamond detector
    Fidanzio, A
    Azario, L
    Viola, P
    Ascarelli, P
    Cappelli, E
    Conte, G
    Piermattei, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 524 (1-3): : 115 - 123
  • [38] Characteristics of microSilicon diode detector for electron beam dosimetry
    Akino, Yuichi
    Das, Indra J.
    Fujiwara, Masateru
    Kaneko, Akari
    Masutani, Takashi
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Suzuki, Osamu
    Seo, Yuji
    Tamari, Keisuke
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1130 - 1138
  • [39] BETATRON ELECTRON-BEAM CHARACTERIZATION FOR DOSIMETRY CALCULATIONS
    STEBEN, JD
    AYYANGAR, K
    SUNTHARALINGAM, N
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (02): : 299 - 309
  • [40] CELLOPHANE DOSIMETRY OF ELECTRON BEAM GENERATED BY VANDEGRAAFF ACCELERATOR
    CHEN, TJ
    YEH, SJ
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1965, 12 (04) : 127 - &