A Rapid Field Calibrating Method for MIMU

被引:0
|
作者
Fan, Yubao [1 ]
Li, Jie [1 ]
Wang, Bo [1 ]
Tian, Xiaochun [1 ]
Liu, Jun [1 ]
机构
[1] N Univ China, Sci & Technol Elect Test & Measurement Lab, Taiyuan 030051, Peoples R China
关键词
IMU; field calibration; ellipsoid fitting; zero bias; scale factor;
D O I
10.4028/www.scientific.net/AMM.80-81.1140
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
When the Micro Inertial Measurement Unit is been placed randomly in the case of stationary, the sum vectors that measured by the inertial devices configured orthogonally along three axis, are constant vectors. In view of the above objective facts, a field calibration method of micro inertial measurement unit was proposed. On the base of the establishment and optimization of calibration model, all parameters to be calibrated can be obtained through the least square by the ellipsoid fitting, with the result of high-precision field calibration for micro inertial measurement unit. Finally, a filed calibration program for micro inertial measurement unit is scheduled reasonably. The experiment results show that the method has such characteristics such as easily-operation, time-saving, higher calibration accuracy, and not depending on the baseline direction and datum offered by precision instruments. Especially, it fits for inertial measurement systems which work short time and ask for high accuracy. In addition, it can also significantly increase the measurement accuracy of micro inertial measurement system in practical application.
引用
收藏
页码:1140 / 1144
页数:5
相关论文
共 50 条
  • [41] VALIDATION OF A RAPID COLORIMETRIC METHOD WITH FIELD SOILS
    Lee, S. Y.
    Park, H. J.
    Han, C. W.
    Lee, S. Y.
    Kweon, G.
    TRANSACTIONS OF THE ASABE, 2017, 60 (04) : 1271 - 1278
  • [42] RAPID FIELD METHOD FOR DETECTING OIL IN SEDIMENTS
    BROWN, LR
    PABST, GS
    LIGHT, M
    MARINE POLLUTION BULLETIN, 1978, 9 (03) : 81 - 82
  • [43] A new method for calibrating hygrometers
    Huang, Jianhua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (04):
  • [44] An alternate method for calibrating the thrombelastograph
    McNulty, SE
    Maguire, DP
    Arai, LD
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (06) : 639 - 641
  • [45] Field trip as Method: A Rapid Fieldwork Approach
    Eden, Grace
    Sharma, Sumita
    Roy, Debjani
    Joshi, Anirudha
    Nocera, Jose Abdelnour
    Rangaswamy, Nimmi
    PROCEEDINGS OF THE 10TH INDIAN CONFERENCE ON HUMAN-COMPUTER INTERACTION (INDIA HCI 2019), 2019, : 1 - 7
  • [46] A new method of head attitude tracking based on CCD/MIMU
    Ma Kai
    Ding Quanxin
    Zhang Qiuzhi
    Wang Jianghua
    Wang Yongsheng
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [47] A METHOD FOR CALIBRATING A HYGROMETER FOR REFRACTORY MATERIALS
    EFREMOV, VA
    KHRAMOV, VN
    REFRACTORIES, 1984, 25 (7-8): : 457 - 460
  • [48] A method for calibrating a motorized object rig
    Huang, PH
    Tsai, YP
    Lo, WY
    Shih, SW
    Chen, CS
    Hung, YP
    COMPUTER VISION - ACCV 2006, PT I, 2006, 3851 : 379 - 388
  • [49] Typical method for calibrating fieldbus transmitters
    不详
    ASSEMBLY AUTOMATION, 2007, 27 (04) : 361 - 361
  • [50] METHOD FOR CALIBRATING COMMERCIAL MICROWAVE HYGROMETERS
    Kovaleva, A. A.
    Saitov, R. I.
    Zaporozhets, A. S.
    Parfenova, E. G.
    MEASUREMENT TECHNIQUES, 2017, 60 (03) : 305 - 308