A Rapid Field Calibrating Method for MIMU

被引:0
|
作者
Fan, Yubao [1 ]
Li, Jie [1 ]
Wang, Bo [1 ]
Tian, Xiaochun [1 ]
Liu, Jun [1 ]
机构
[1] N Univ China, Sci & Technol Elect Test & Measurement Lab, Taiyuan 030051, Peoples R China
关键词
IMU; field calibration; ellipsoid fitting; zero bias; scale factor;
D O I
10.4028/www.scientific.net/AMM.80-81.1140
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
When the Micro Inertial Measurement Unit is been placed randomly in the case of stationary, the sum vectors that measured by the inertial devices configured orthogonally along three axis, are constant vectors. In view of the above objective facts, a field calibration method of micro inertial measurement unit was proposed. On the base of the establishment and optimization of calibration model, all parameters to be calibrated can be obtained through the least square by the ellipsoid fitting, with the result of high-precision field calibration for micro inertial measurement unit. Finally, a filed calibration program for micro inertial measurement unit is scheduled reasonably. The experiment results show that the method has such characteristics such as easily-operation, time-saving, higher calibration accuracy, and not depending on the baseline direction and datum offered by precision instruments. Especially, it fits for inertial measurement systems which work short time and ask for high accuracy. In addition, it can also significantly increase the measurement accuracy of micro inertial measurement system in practical application.
引用
收藏
页码:1140 / 1144
页数:5
相关论文
共 50 条
  • [21] A new initial alignment method of MIMU based on CCD
    Ma, Kai
    Ding, Quanxin
    Zhang, Qiuzhi
    Chen, Shaodong
    Wang, Yongsheng
    7TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2014, 9282
  • [22] A RAPID AND ACCURATE DEVICE FOR CALIBRATING WARBURG RESPIROMETER
    YANAGUCH.M
    HOWARD, FD
    PRATT, HK
    ANALYTICAL BIOCHEMISTRY, 1966, 16 (02) : 338 - &
  • [23] Research on MIMU adaptive filter method based on wavelet analysis
    Chen Xiaoguang
    Fang Jiancheng
    SIGNAL ANALYSIS, MEASUREMENT THEORY, PHOTO-ELECTRONIC TECHNOLOGY, AND ARTIFICIAL INTELLIGENCE, PTS 1 AND 2, 2006, 6357
  • [24] A method of calibrating gas meters
    Benedict, FG
    PHYSICAL REVIEW, 1906, 22 (05): : 294 - 299
  • [25] AN OFFICE METHOD FOR CALIBRATING A UROFLOWMETER
    RYALL, RL
    MARSHALL, VR
    JOURNAL OF UROLOGY, 1982, 127 (03): : 482 - 483
  • [26] METHOD FOR CALIBRATING IMPACT ACCELEROMETERS
    LUPINSKII, MM
    SAVITSKII, FS
    MEASUREMENT TECHNIQUES-USSR, 1971, 14 (07): : 1007 - +
  • [27] AN AREAL METHOD FOR CALIBRATING MICROBURETTES
    BUCK, JB
    KEISTER, ML
    ZELLE, MR
    ANALYTICA CHIMICA ACTA, 1950, 4 (02) : 130 - 134
  • [28] SIMPLE METHOD OF CALIBRATING THERMOCOUPLES
    SIMA, V
    MISEK, K
    BEDNAR, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1973, 23 (05) : 577 - 580
  • [29] A Method of Calibrating Critical Nozzles
    B. M. Belyaev
    V. V. Vagin
    V. G. Patrikeev
    Measurement Techniques, 2002, 45 : 395 - 399
  • [30] SUBSTITUTION METHOD FOR CALIBRATING A MICROPHONE
    MADELLA, GB
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1948, 20 (04): : 550 - 551