A Rapid Field Calibrating Method for MIMU

被引:0
|
作者
Fan, Yubao [1 ]
Li, Jie [1 ]
Wang, Bo [1 ]
Tian, Xiaochun [1 ]
Liu, Jun [1 ]
机构
[1] N Univ China, Sci & Technol Elect Test & Measurement Lab, Taiyuan 030051, Peoples R China
关键词
IMU; field calibration; ellipsoid fitting; zero bias; scale factor;
D O I
10.4028/www.scientific.net/AMM.80-81.1140
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
When the Micro Inertial Measurement Unit is been placed randomly in the case of stationary, the sum vectors that measured by the inertial devices configured orthogonally along three axis, are constant vectors. In view of the above objective facts, a field calibration method of micro inertial measurement unit was proposed. On the base of the establishment and optimization of calibration model, all parameters to be calibrated can be obtained through the least square by the ellipsoid fitting, with the result of high-precision field calibration for micro inertial measurement unit. Finally, a filed calibration program for micro inertial measurement unit is scheduled reasonably. The experiment results show that the method has such characteristics such as easily-operation, time-saving, higher calibration accuracy, and not depending on the baseline direction and datum offered by precision instruments. Especially, it fits for inertial measurement systems which work short time and ask for high accuracy. In addition, it can also significantly increase the measurement accuracy of micro inertial measurement system in practical application.
引用
收藏
页码:1140 / 1144
页数:5
相关论文
共 50 条
  • [1] Design of Automated Batch Calibrating System for MIMU
    Yin, Juan
    Zhu, Xinhua
    Wu, Zhiqiang
    2016 10TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2016,
  • [2] A CONVENIENT AND RAPID METHOD OF CALIBRATING WARBURG MANOMETERS
    LOOMIS, WF
    SCIENCE, 1949, 109 (2837) : 491 - 492
  • [3] A RAPID AND CONVENIENT METHOD OF CALIBRATING FLUORESCENCE MICROSCOPES
    DEMIAN, J
    SCHWARTZ, A
    AMERICAN LABORATORY, 1988, 20 (04) : 122 - 123
  • [4] RAPID METHOD FOR CALIBRATING AND CHECKING VISUAL PYROMETERS
    KOGAN, AV
    MASNYAK, II
    MEASUREMENT TECHNIQUES USSR, 1989, 32 (04): : 358 - 360
  • [5] CALIBRATING AND CHECKING VACUUM GAUGES BY A RAPID METHOD
    KUZMIN, VV
    MEASUREMENT TECHNIQUES USSR, 1983, 26 (08): : 645 - 647
  • [6] MIMU field calibration method based on PE-ANGO
    Qiao M.
    Yao W.
    Gao K.
    Du H.
    Zhao K.
    Zhongguo Guanxing Jishu Xuebao/Journal of Chinese Inertial Technology, 2024, 32 (02): : 107 - 114and124
  • [7] A new method for calibrating reference and field pyranometers
    Forgan, BW
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1996, 13 (03) : 638 - 645
  • [8] A RAPID METHOD FOR CALIBRATING SOIL MOISTURE ELEMENTS OF THE POROUS BLOCK TYPE
    CLOSS, RL
    SOIL SCIENCE, 1954, 78 (05) : 333 - 338
  • [9] A rapid method of calibrating various instruments for measuring soil moisture in situ
    Kelley, OJ
    SOIL SCIENCE, 1944, 58 (01) : 433 - 440
  • [10] A NEW METHOD OF CALIBRATING FIELD-STRENGTH MEASURING EQUIPMENT
    DINGER, HE
    GARNER, WE
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1952, 40 (06): : 743 - 743