In Vitro Evaluation of Heat and Moisture Exchangers Designed for Spontaneously Breathing Tracheostomized Patients

被引:7
|
作者
Brusasco, Claudia [1 ]
Corradi, Francesco [3 ]
Vargas, Maria [1 ,6 ]
Bona, Margherita [1 ]
Bruno, Federica [1 ]
Marsili, Maria [1 ]
Simonassi, Francesca [1 ]
Santori, Gregorio [2 ]
Severgnini, Paolo [4 ]
Kacmarek, Robert M. [5 ]
Pelosi, Paolo [1 ]
机构
[1] Univ Genoa, Ist Ricovero & Cura Carattere Sci, Azienda Osped Univ San Martino,Sez Anestesia & Ri, Dipartimento Sci Chirurg & Diagnost Integrate, I-16132 Genoa, Italy
[2] Univ Genoa, Ist Ricovero & Cura Carattere Sci, Azienda Osped Univ San Martino, Dipartimento Sci Chirurg & Diagnost Integrate, I-16132 Genoa, Italy
[3] Azienda Ospedaliero Univ Parma, Sez Terapia Intens Cardiochirurg, Dipartimento Cardionefropolmonare, I-43100 Parma, Italy
[4] Univ Insubria, Dipartimento Sci & Alta Tecnol, Sez Ambiente Salute Sicurezza Terr, Varese, Italy
[5] Massachusetts Gen Hosp, Resp Care Serv, Boston, MA 02114 USA
[6] Univ Naples Federico II, Dipartimento Anestesia & Terapia Intens, Naples, Italy
关键词
tracheostomized patients; absolute humidity; inspiratory air temperature; air conditioning; heat and moisture exchangers; 48 HOURS RATHER; MICROBIOLOGICAL EVALUATION; TEMPERATURE DYNAMICS; TOTAL LARYNGECTOMY; SYSTEM FILTERS; CHANGING HEAT; WATER-VAPOR; HUMIDIFICATION; HUMIDITY; PERFORMANCE;
D O I
10.4187/respcare.02405
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O-2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations ((V) over dot(E)) and supplemental O-2 flows. METHODS: HME efficiency was evaluated using an in vitro lung model at 2 (V) over dot(E) (5 and 15 L/min) and 4 supplemental O-2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. RESULTS: The progressive increase in O-2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower (V) over dot(E). The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 degrees C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. CONCLUSIONS: The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O-2 supplementation and (V) over dot(E). (C) 2013 Daedalus Enterprises
引用
收藏
页码:1878 / 1885
页数:8
相关论文
共 50 条
  • [41] Heat and moisture exchangers as a treatment option in the post-operative rehabilitation of laryngectomized patients
    Ackerstaff, AH
    Hilgers, FJM
    Aaronson, NK
    DeBoer, MF
    Meeuwis, CA
    Knegt, PPM
    Spoelstra, HAA
    VanZandwijk, N
    Balm, AJM
    CLINICAL OTOLARYNGOLOGY, 1995, 20 (06): : 504 - 509
  • [42] Influence of heat and moisture exchangers on dead space and gas exchange in patients with respiratory distress
    Suau, AC
    Bellapart, J
    Cancio, B
    Moran, I
    Mancebo, J
    INTENSIVE CARE MEDICINE, 2001, 27 : S246 - S246
  • [43] EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS
    CONTI, G
    DEBLASI, RA
    ROCCO, M
    PELAIA, P
    ANTONELLI, M
    BUFI, M
    MATTIA, C
    GASPARETTO, A
    INTENSIVE CARE MEDICINE, 1990, 16 (07) : 441 - 443
  • [44] Difficult to wean chronic obstructive pulmonary disease patients: Avoid heat and moisture exchangers?
    Hilbert, G
    CRITICAL CARE MEDICINE, 2003, 31 (05) : 1580 - 1581
  • [46] A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings
    N. Ünal
    J. K. K. Kanhai
    S. L. C. E. Buijk
    J. C. Pompe
    W. P. J. Holland
    I. Gültina
    C. Ince
    B. Saygin
    H. A. Bruining
    Intensive Care Medicine, 1998, 24 : 138 - 146
  • [47] A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings
    Unal, N
    Kanhai, JKK
    Buijk, SLCE
    Pompe, JC
    Holland, WPJ
    Gultuna, I
    Ince, C
    Saygin, B
    Bruining, HA
    INTENSIVE CARE MEDICINE, 1998, 24 (02) : 138 - 146
  • [48] Partial liquid ventilation: effects of closed breathing systems, heat- and-moisture-exchangers and sodalime absorbers on perfluorocarbon evaporation
    Wilms, CT
    Schober, P
    Kalb, R
    Loer, SA
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (01) : 31 - 35
  • [49] In Vitro Evaluation of an Active Heat-and-Moisture Exchanger: The Hygrovent Gold
    Pelosi, Paolo
    Severgnini, Paolo
    Selmo, Gabriele
    Corradini, Michela
    Chiaranda, Maurizio
    Novario, Raffaele
    Park, Gilbert R.
    RESPIRATORY CARE, 2010, 55 (04) : 460 - 466
  • [50] Do heat and moisture exchangers in the anaesthesia breathing circuit preserve body temperature in dogs undergoing anaesthesia for magnetic resonance imaging?
    Khenissi, Latifa
    Covey-Crump, Gwen
    Knowles, Toby G.
    Murrell, Joanna
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (03) : 452 - 460